m. allan noah
91598aa800
* backend/*.[ch]: nearly every backend used V_MAJOR
...
instead of SANE_CURRENT_MAJOR in sane_init()
* backend/snapscan.c: remove EXPECTED_VERSION check
since new SANE standard is forward compatible
2008-11-26 21:21:31 +00:00
Peter Kirchgessner
07a22cd39f
Rename global function hp_init_openfd to sanei_hp_init_openfd
2004-10-04 18:09:05 +00:00
Peter Kirchgessner
d77b4b4736
Keep USB-connection open (was problem with Linux 2.6.x)
2004-03-27 13:52:39 +00:00
Peter Kirchgessner
d66b755e7f
Use new sanei-thread-interface
2003-10-24 17:26:07 +00:00
Peter Kirchgessner
d5b479a19a
Redo when TEST UNIT READY failed
...
Redo when read returns with 0 bytes (non-SCSI only)
Bug #300241 : fix invers image on 3c/4c/6100C at 10 bit depth
2003-10-09 19:37:29 +00:00
Peter Kirchgessner
22020eba9c
Bug #300248 : correct "Negatives" to "Negative" in option description
2003-10-06 19:54:07 +00:00
Peter Kirchgessner
030e0f0722
Add SANE_I18N
2003-07-24 18:31:58 +00:00
Peter Kirchgessner
3b43770843
Second try to fix problem with null-pointer in sane_control_option
2003-04-14 19:29:37 +00:00
Peter Kirchgessner
b35cbffda9
check pointer received from sane_control_option()
2003-04-14 18:20:41 +00:00
Peter Kirchgessner
216c5cec42
Add OS/2-support for hp-backend
2003-02-02 17:03:36 +00:00
Peter Kirchgessner
41cdb74d97
Workaround problem with Buslogic SCSI driver in hp-backend
2002-12-06 19:46:39 +00:00
Peter Kirchgessner
09538261ab
Add libusb-support to hp-backend
2002-11-25 20:36:36 +00:00
Peter Kirchgessner
f60b851fa7
HP-backend V0.96. Check device names to prevent USB-device to be
...
opened as SCSI-device
2002-08-06 19:33:08 +00:00
Peter Kirchgessner
b94f799b28
- add support for active XPA
...
- check if paper in ADF for ADF scan
- add option lamp off
- remove some really unused parameters
2001-09-04 13:51:11 +00:00
Peter Kirchgessner
90cafb8935
Switch off lamp after scan
2001-02-04 17:36:26 +00:00
Peter Kirchgessner
f1a237520c
Fix problem with ADF-support (hp backend)
2000-12-04 21:03:43 +00:00
Peter Kirchgessner
2ba681f320
Write warning for missing ptal support with DBG(0...
2000-11-26 13:44:12 +00:00
Peter Kirchgessner
fcf012d292
Change sanei_debug-interface
...
Allocate accessor only once (for fixed size accessors)
2000-10-23 18:32:37 +00:00
Peter Kirchgessner
e907811055
hp-backend V 0.91, 04-Sep-2000, David Paschal (paschal@rcsis.com):
...
- Added support for flatbed HP OfficeJets
- (PK) fix problem with cancel preview
hp-backend V 0.91, V 0.90, 02-Sep-2000, PK:
- fix timing problem between killing child and writing to pipe
- change fprintf(stderr,...) to DBG
- change include <sane..> to "sane.." in hp.h
- change handling of options that have global effects.
i.e. if option scanmode is received (has global effect),
all options that "may change" are send to the scanner again.
This fixes a problem that --resolution specified infront of
--mode on command line of scanimage was ignored.
NOTE: This change does not allow to specify --depth 12 infront of
--mode color, because --depth is only enabled with --mode color.
- add depth greater 8 bits for mode grayscale
- add option for 8 bit output but 10/12 bit scanning
2000-09-09 17:44:14 +00:00
Petter Reinholdtsen
b4a1a513c9
Merge devel (v1.0.3) into head branch.
2000-08-12 15:11:46 +00:00
Petter Reinholdtsen
760423d864
Merged main branch with current DEVEL_1_9.
2000-03-05 13:57:25 +00:00
Petter Reinholdtsen
30ab5e718a
Initial revision
1999-08-09 18:06:01 +00:00