Wykres commitów

152 Commity (7cd9688e1fd1afeb6b72cfa811b461380bf6efcb)

Autor SHA1 Wiadomość Data
Henning Geinitz a543ca8242 PACKAGE_VERSION fix. Fixed debug message in do_stop: really print exit status
of reader process.
2002-11-29 18:22:00 +00:00
Peter Kirchgessner 2869385331 hp-backend V 1.00 (libusb support 2002-11-25 20:40:43 +00:00
Henning Geinitz 089b24e539 Changed 150 to 200 dpi for Mustek BearPaw 2400 TA. Fixed warnings in
gt68xx_low.c. Used DBG instead of XDBG ing gt68xx_low.c.  Minor manpage
fixes. Added man page links to other backends.  gt68xx_low.h: Fixed
__FUNCTION__ bug on non-gcc compilers.  Added more details about the BSDs in
the manpage. Fixed color order for ScanExpress A3 USB.
2002-11-21 22:09:16 +00:00
Henning Geinitz 8579e4d517 Minor manpage fixes. Added links to similar backends. More information about
non-Linux OS.
2002-11-21 21:38:43 +00:00
Michael Herder e33067f8ea Initial check-in 2002-11-20 12:21:53 +00:00
Henning Geinitz 4ef48fd6e6 Added basic support for Plustek OpticPro 1248U (from Gerhard Jaeger
<gerhard@gjaeger.de>). Removed 50 and 1200 dpi from Lexmark X73.  Backend
status is BETA now.
2002-11-13 17:45:24 +00:00
Ulrich Deiters 0a43a10869 upgraded Canon SCSI backend to version 1.10:
modified invocations of sanei_scsi_open() to avoid crashes with Mandrake Linux
added support of focus control for the FS2710S film scanner
2002-11-13 13:22:49 +00:00
Henning Geinitz 912c6f300d Upload linear gamma table for Pro models if custom gamma is off instead of
uploading the composed gamma table. That avoids applying gamm twice. Minor man
page update.
2002-11-07 13:18:17 +00:00
Henning Geinitz 1eee8d286e Changed option titles and descriptions to make them better readable. Added
translation markers for all options. Added German translation for backend
options. Updated manpage and .desc file concerning scanner status. Added
untested flag for Mustek ScanEpress A3 USB and Lexmark X73.
2002-11-07 12:50:19 +00:00
Henning Geinitz bc2a2f1d1c Added documentation for gt68xx backend. 2002-10-25 12:19:34 +00:00
Gerhard Jaeger eff5c115cb Many small fixes and documentation update. 2002-10-15 18:02:53 +00:00
Oliver Schwartz 07e207ba40 SnapScan backend 1.4.17 2002-10-14 21:49:45 +00:00
Frank Zago 32c28abac4 Added entry for AVEC color 2412. 2002-10-09 17:54:21 +00:00
Henning Geinitz 5cb6875fdf Added per-scanner status (from Karsten Festag <karsten.festag@gmx.de>). 2002-10-09 15:49:24 +00:00
Jochen Eisinger 5c746fdfd1 2002-10-04 Jochen Eisinger <jochen.eisinger@gmx.de>
* doc/descriptions/mustek_pp.desc: add :status tags to each
	  scanner
2002-10-04 18:27:13 +00:00
Matto Marjanovic e1c7205510 2002-10-02 Matto Marjanovic <maddog@mir.com>
* doc/descriptions/microtek.desc: Updated version number.
	* backend/microtek.c:
	  Fixed bug in sane_read() [had failed to set return length to zero
           in non-STATUS_GOOD conditions].
	  Fixed bug in sane_set_io_mode() [had returned SANE_STATUS_UNSUPPORTED
           if blocking mode was requested].
	  Bumped version up to 0.13.1.
2002-10-02 05:05:15 +00:00
Oliver Rauch e11c6074db updated umax.desc 2002-09-30 16:33:35 +00:00
Matthew Duggan 284233e77e * backend/canon_pp.c backend/canon_pp-dev.c backend/canon_pp-dev.h:
Finally fixed cancelling, which I broke some time ago in the quest
  for speed.  FB620P still doesn't abort nicely (firmware bug?).
* doc/sane-canon_pp.man: Added notes on FB620P problems.
* doc/descriptions/canon_pp.desc: Bumped version number.
2002-09-30 15:25:14 +00:00
Henning Geinitz 2958f7a844 Fixed bytes_per_line in 1 bit mode. Fixed 1 bit color three-pass mode
(grid). Changed bit order for 1 bit color to most significant bit is first
pixel.
2002-09-30 13:54:02 +00:00
Henning Geinitz 5ba6652c3e Added "ScanExpress" for all models to avoid confusion with BearPaw models. 2002-09-29 20:45:56 +00:00
Karl Heinz Kremer 07329038f7 Updated man page and added Perfection 1660 and 2400 to desc file. 2002-09-29 16:28:15 +00:00
Gerhard Jaeger ff6e86ef36 Major update to support Canon CIS scanner N670/676U and N650/656U 2002-09-28 11:31:53 +00:00
Andras Major 6e2c579cc1 coolscan2 update to 0.1.8 2002-09-28 07:59:11 +00:00
Frank Zago 6f74e1e76d Added ":new :yes". 2002-09-27 00:13:57 +00:00
Oliver Schwartz 97044ee3e3 SnapScan backend 1.4.16 (support for Acer/Benq 5000) 2002-09-26 20:09:24 +00:00
Henning Geinitz c3a39fe4d3 Changed status to beta and added URLs. 2002-09-23 10:16:54 +00:00
Frank Zago 8c0b86ca08 Added support for the LEOScan S3. 2002-09-20 02:59:18 +00:00
Henning Geinitz 21d4e19d22 Used "Hewlett-Packard" instead of "HP". 2002-09-18 20:43:10 +00:00
Oliver Schirrmeister d387cfe539 added 3092 support 2002-09-17 11:19:07 +00:00
Matthew Duggan 51a3075282 * backend/canon_pp-dev.c backend/canon_pp-dev.h backend/canon_pp-io.c
backend/canon_pp-io.h backend/canon_pp.c backend/canon_pp.h:
  Fix init problem, add changes to facilitate configurable wakeup mode
  (for faster starts on FB360P and FB620P).
* doc/sane-canon_pp.man doc/descriptions/canon_pp.desc: Updates
  regarding FB310P and FB610P (rebadged Avisions)
2002-09-16 13:42:51 +00:00
Oliver Rauch b5c3730dcd 2002-09-13 Oliver Rauch <Oliver.Rauch@rauch-domain.de>
* backend/umax-scanner.c, backend/umax.conf
          doc/descriptions/umax.desc:
          added Linotype Hell SAPHIR3 as supported scanner
2002-09-13 14:27:32 +00:00
Oliver Rauch 2865131e36 2002-09-11 Oliver Rauch <Oliver.Rauch@rauch-domain.de>
* doc/descriptions/umax.desc: corrected some urls
2002-09-11 20:38:56 +00:00
Henning Geinitz 2887a1a24f Added fb636u as unsupported. Added status information. 2002-09-11 19:02:29 +00:00
Frank Zago da6aa74692 Added threshold option for b&w. 2002-09-07 21:32:25 +00:00
Marcio Teixeira 1a62a5f0f0 Removed the "Incompatible" note for the UMAX2200US since it is supported by the "umax" backend. 2002-09-07 18:37:15 +00:00
Oliver Rauch 19b99d7197 updated umax.desc 2002-09-07 16:32:11 +00:00
Oliver Rauch 5e2087a43f Update of umax.desc: PowerLook 2100XL stable 2002-09-07 16:13:42 +00:00
Oliver Rauch 08bc05d7cd 2002-09-07 Oliver Rauch <Oliver.Rauch@rauch-domain.de>
* backend/umax.c, umax.h, umax-scanner.c, umax.conf
          doc/descriptions/umax.desc
          Update to sane-umax build 36
2002-09-07 10:11:17 +00:00
Matthew Duggan 45bf928a3c * doc/sane-canon_pp.man doc/descriptions/canon_pp.desc:
Added FB320P to supported scanners after report of successful test.
  Added FB310P and FB610P to desc as specifically not supported yet.
2002-09-03 15:20:49 +00:00
Peter Kirchgessner ea238f9bb7 Peter Kirchgessner: applied patch by David Paschal to remove PTAL-support 2002-09-01 17:47:37 +00:00
Matthew Duggan f0722f0d5c Added support for FB620P to canon_pp backend. 2002-09-01 08:57:34 +00:00
Frank Zago 1e2e1f8cd2 backend integrated. 2002-08-31 15:46:31 +00:00
Frank Zago c8b46ff4f7 Added vm3510. 2002-08-31 02:54:15 +00:00
Rene Rebe c67286adee Commited the latest avision backend. 2002-08-30 09:21:51 +00:00
Henning Geinitz 6fdbf3b2fe Minor fixes and updates for the new .desc file format. 2002-08-29 20:12:44 +00:00
Henning Geinitz 8b0a038f61 Big clean up of Video for Linux backend. Removed old unused stuff from qcam
and others including unused options and variables concerning direct port
access. Removed wcam license (no "substantial portions of code" are used any
more). Removed unuesed headers. Made lots of global variables local. Lots of
checks for null pointer dereferences and errors when opening files or using
ioctl/mmap. Added option to select grey or color mode. Added support for
different channels. Fixed lots of options.  Made sure ioctls are only used
when necessary.  Used vendor == "Noname".  Added ??? comments for suspicious
code.  Lots of minor fixes and cleanup. Added version number: 1.0-2.
2002-08-29 19:34:53 +00:00
Frank Zago 88bda0db33 Increased version number. 2002-08-23 01:37:14 +00:00
Frank Zago 6259eb59d9 Added 3 new (untested) scanners. 2002-08-23 01:15:42 +00:00
Andras Major 29b7b4d674 coolscan2 update to 0.1.7 2002-08-21 23:36:00 +00:00
Gerhard Jaeger 28edd2af4d Major update. Better support for LM983x based devices. 2002-08-16 11:43:30 +00:00