-) LAN and USB communication
-) SNMP LAN auto-detection (using libsnmp, added configure check!)
-) Based on the epson2 backend, with many structural changes
-) B/W, Gray, Color scanning works in 150/300/600dpi (full-page
color scan only possible with <=300dpi)
-) The timeouts (SNMP, scan data, other data) are configurable in the
magicolor.conf file
-) Keeps list of known scanners in sane_get_devices, does not destroy
existing handles; Also correctly calls sanei_usb_init.
Added
void sanei_usb_set_endpoint (SANE_Int dn, SANE_Int ep_type, SANE_Int ep);
This function allows the user to set the endpoint to use on
the given device for the given endpoint type (e.g. bulk in).
Some scanners have multiple bulk in/out endpoints but use
only one for communication (not the one detected during auto-detection),
so one call to the new function will change the used endpoint.
Some scanners use two different endpoint for different purposes,
so in that case each read/write call needs to be preceeded
by a call to that function to set the proper endpoint.
ep_type is a bitmask and is usually of the form
(USB_DIR_IN|USB_ENDPOINT_TYPE_BULK)
Allow "make dist" when translations are disabled.
Allow "make check" to work by linking in liblib.la.
Signed-off-by: Chris Bagwell <chris@cnpbagwell.com>
- backup and restore image params around image processing code
- cache software crop/deskew parameters for use on backside of duplex
- fi-6110 does not support bgcolor or prepick
* include/sane/sanei_config.h sanei/sanei_config.c: Add function
sanei_config_get_paths to obtain all configuration pathes (from env var
SANE_CONFIG_DIR and default paths); fix pointers to invalid/freed
strings when SANE_CONFIG_DIR is set
* backend/dll.c: When searching for the dll.d/ directory, also use
the SANE_CONFIG_DIR env variable.