Wykres commitów

225 Commity (6520e41917a1ec1d3c9b340210914a461f704418)

Autor SHA1 Wiadomość Data
Gerhard Jaeger 8ba08fdfca Update to version 0.45, added some new models and support for libusb. 2003-01-10 13:32:11 +00:00
Henning Geinitz 3451798f08 Updated (From Karsten Festag <karsten.festag@gmx.de>). 2003-01-09 18:07:17 +00:00
Henning Geinitz 9f0d82980b Updated manpage and .desc concerning Lexmark X70. Updated manpage concerning
kernel 2.4.21-pre3 containing the 1-endpoint fix. Fixed A3 USB resolution
setting. Updated A3 USB margins (Pedro Morais <morais@inocam.com>). Added
detection of Genius Colorpage Vivid3x.  It's unknown if it works. Updated
.desc file. Don't print calib line warnings by default.
2003-01-09 18:05:01 +00:00
Oliver Schwartz 42f2440739 Update to snapscan backend 1.4.18 2003-01-08 21:45:28 +00:00
Henning Geinitz 6f96e5795c Added Canon CanoScan D1250U2 and HP ScanJet 4400C. 2003-01-08 15:38:30 +00:00
Henning Geinitz 6b888cf8d4 Use uniform model names for HP scanners. 2003-01-08 15:36:34 +00:00
Peter Kirchgessner 429aa6e156 anged GP ScanJet to ScanJet in hp.desc 2003-01-07 06:41:46 +00:00
Stéphane Voltz 6ee9e076de - man update
- model name change
2003-01-07 06:16:39 +00:00
Peter Fales d68fecc63b Update author info 2003-01-07 05:39:47 +00:00
Peter Fales ff4cea927c Updated author info and description 2003-01-07 05:35:52 +00:00
Matthew Duggan e9220432d0 2003-01-07 Matthew Duggan <stauff1@users.sourceforge.net>
* backend/canon_pp-dev.c: Improve/fix detection logic.
* doc/descriptions/canon_pp.desc: Bump version number.
2003-01-07 05:14:28 +00:00
Henning Geinitz 6a432ce796 Added Genius HR7X Slim, Visioneer 6200 and Onetouch 8920. 2003-01-04 15:28:42 +00:00
Henning Geinitz c071d883d8 Added list of (known) scanners that are not supported by a SANE backend. There
may be information about them or even a standaalone program to which the
entries point.
2002-12-31 15:11:35 +00:00
Henning Geinitz f63abd633e Make sure that frontend bugs concerning the select fd are detected. 2002-12-30 13:44:27 +00:00
Henning Geinitz b97a0721b5 Updated ScanExpress 2400 USB values. Added implementation of gt6801 lamp
control for CCD scanners. Added flag for SE 2400 USB, added some quirks in
gt68xx_gt6801.c. Fixed gt68xx_gt6801 -> lamp control. Adjusted Plustek 1248U
geometry and afe values. CCD gross calibration changed: start with the default
value from module struct. Is faster now for most cases. Only 2.5 mm of
calibration for GT-6801 scanners. Added "afe" option for gt68xx.conf for
selecting default afe values. Removed AFE and exposure SANE options. Added
documentation for afe option in gt68xx.conf. New version: 1.0-35.
2002-12-30 13:05:24 +00:00
Henning Geinitz 76524496d9 Updated NEW! markers. 2002-12-08 21:04:49 +00:00
Henning Geinitz 7f699acfe3 Coarse calibration for first scan only" is off by default now. Added gamma
table factor option (SANE_CAP_EMULATED). Setup gamma to 2.0 by default.  Fixed
(hopefully) sigpipe when cancelling. No geometry quantization anymore (not
necessary). Plustek 1248U: do linemode for every resolution, fix color
correction. Added comments for every Model member in gt68xx_devices.  Added
Plustek UT16B and Genius Vivid3x to .desc. Added implementation for inverted
offset for CCD scanners. Added Mustek ScanExpress 2400 USB. Well, at least
it's detected. Added NEW marker to .desc.
2002-12-08 21:00:31 +00:00
Peter Kirchgessner 35f5cdf6e0 Add option to work around "error during device I/O" 2002-12-06 20:14:36 +00:00
Henning Geinitz 799dab5533 Updated links. 2002-12-05 08:48:22 +00:00
Henning Geinitz 9e0f5f2a58 Ignore comments that are in the same line as the backend entries. Minor
manpage fixes.
2002-12-04 20:25:13 +00:00
Matthew Duggan d44ae2c92e 2002-12-04 Matthew Duggan <stauff1@users.sourceforge.net>
* backend/canon_pp-dev.c: Don't compare firmware version numbers -
	  multiple versions do actually exist.
	* doc/descriptions/canon_pp.desc: Bump version number.
2002-12-04 05:35:38 +00:00
Rene Rebe f0acf4c68a syntax fix 2002-12-01 19:05:50 +00:00
Rene Rebe 3e1655a2ce New avision backend - including the auto-generated .desc file. 2002-12-01 13:42:18 +00:00
Henning Geinitz a543ca8242 PACKAGE_VERSION fix. Fixed debug message in do_stop: really print exit status
of reader process.
2002-11-29 18:22:00 +00:00
Peter Kirchgessner 2869385331 hp-backend V 1.00 (libusb support 2002-11-25 20:40:43 +00:00
Henning Geinitz 089b24e539 Changed 150 to 200 dpi for Mustek BearPaw 2400 TA. Fixed warnings in
gt68xx_low.c. Used DBG instead of XDBG ing gt68xx_low.c.  Minor manpage
fixes. Added man page links to other backends.  gt68xx_low.h: Fixed
__FUNCTION__ bug on non-gcc compilers.  Added more details about the BSDs in
the manpage. Fixed color order for ScanExpress A3 USB.
2002-11-21 22:09:16 +00:00
Henning Geinitz 8579e4d517 Minor manpage fixes. Added links to similar backends. More information about
non-Linux OS.
2002-11-21 21:38:43 +00:00
Michael Herder e33067f8ea Initial check-in 2002-11-20 12:21:53 +00:00
Henning Geinitz 4ef48fd6e6 Added basic support for Plustek OpticPro 1248U (from Gerhard Jaeger
<gerhard@gjaeger.de>). Removed 50 and 1200 dpi from Lexmark X73.  Backend
status is BETA now.
2002-11-13 17:45:24 +00:00
Ulrich Deiters 0a43a10869 upgraded Canon SCSI backend to version 1.10:
modified invocations of sanei_scsi_open() to avoid crashes with Mandrake Linux
added support of focus control for the FS2710S film scanner
2002-11-13 13:22:49 +00:00
Henning Geinitz 912c6f300d Upload linear gamma table for Pro models if custom gamma is off instead of
uploading the composed gamma table. That avoids applying gamm twice. Minor man
page update.
2002-11-07 13:18:17 +00:00
Henning Geinitz 1eee8d286e Changed option titles and descriptions to make them better readable. Added
translation markers for all options. Added German translation for backend
options. Updated manpage and .desc file concerning scanner status. Added
untested flag for Mustek ScanEpress A3 USB and Lexmark X73.
2002-11-07 12:50:19 +00:00
Henning Geinitz bc2a2f1d1c Added documentation for gt68xx backend. 2002-10-25 12:19:34 +00:00
Gerhard Jaeger eff5c115cb Many small fixes and documentation update. 2002-10-15 18:02:53 +00:00
Oliver Schwartz 07e207ba40 SnapScan backend 1.4.17 2002-10-14 21:49:45 +00:00
Frank Zago 32c28abac4 Added entry for AVEC color 2412. 2002-10-09 17:54:21 +00:00
Henning Geinitz 5cb6875fdf Added per-scanner status (from Karsten Festag <karsten.festag@gmx.de>). 2002-10-09 15:49:24 +00:00
Jochen Eisinger 5c746fdfd1 2002-10-04 Jochen Eisinger <jochen.eisinger@gmx.de>
* doc/descriptions/mustek_pp.desc: add :status tags to each
	  scanner
2002-10-04 18:27:13 +00:00
Matto Marjanovic e1c7205510 2002-10-02 Matto Marjanovic <maddog@mir.com>
* doc/descriptions/microtek.desc: Updated version number.
	* backend/microtek.c:
	  Fixed bug in sane_read() [had failed to set return length to zero
           in non-STATUS_GOOD conditions].
	  Fixed bug in sane_set_io_mode() [had returned SANE_STATUS_UNSUPPORTED
           if blocking mode was requested].
	  Bumped version up to 0.13.1.
2002-10-02 05:05:15 +00:00
Oliver Rauch e11c6074db updated umax.desc 2002-09-30 16:33:35 +00:00
Matthew Duggan 284233e77e * backend/canon_pp.c backend/canon_pp-dev.c backend/canon_pp-dev.h:
Finally fixed cancelling, which I broke some time ago in the quest
  for speed.  FB620P still doesn't abort nicely (firmware bug?).
* doc/sane-canon_pp.man: Added notes on FB620P problems.
* doc/descriptions/canon_pp.desc: Bumped version number.
2002-09-30 15:25:14 +00:00
Henning Geinitz 2958f7a844 Fixed bytes_per_line in 1 bit mode. Fixed 1 bit color three-pass mode
(grid). Changed bit order for 1 bit color to most significant bit is first
pixel.
2002-09-30 13:54:02 +00:00
Henning Geinitz 5ba6652c3e Added "ScanExpress" for all models to avoid confusion with BearPaw models. 2002-09-29 20:45:56 +00:00
Karl Heinz Kremer 07329038f7 Updated man page and added Perfection 1660 and 2400 to desc file. 2002-09-29 16:28:15 +00:00
Gerhard Jaeger ff6e86ef36 Major update to support Canon CIS scanner N670/676U and N650/656U 2002-09-28 11:31:53 +00:00
Andras Major 6e2c579cc1 coolscan2 update to 0.1.8 2002-09-28 07:59:11 +00:00
Frank Zago 6f74e1e76d Added ":new :yes". 2002-09-27 00:13:57 +00:00
Oliver Schwartz 97044ee3e3 SnapScan backend 1.4.16 (support for Acer/Benq 5000) 2002-09-26 20:09:24 +00:00
Henning Geinitz c3a39fe4d3 Changed status to beta and added URLs. 2002-09-23 10:16:54 +00:00
Frank Zago 8c0b86ca08 Added support for the LEOScan S3. 2002-09-20 02:59:18 +00:00
Henning Geinitz 21d4e19d22 Used "Hewlett-Packard" instead of "HP". 2002-09-18 20:43:10 +00:00
Oliver Schirrmeister d387cfe539 added 3092 support 2002-09-17 11:19:07 +00:00
Matthew Duggan 51a3075282 * backend/canon_pp-dev.c backend/canon_pp-dev.h backend/canon_pp-io.c
backend/canon_pp-io.h backend/canon_pp.c backend/canon_pp.h:
  Fix init problem, add changes to facilitate configurable wakeup mode
  (for faster starts on FB360P and FB620P).
* doc/sane-canon_pp.man doc/descriptions/canon_pp.desc: Updates
  regarding FB310P and FB610P (rebadged Avisions)
2002-09-16 13:42:51 +00:00
Oliver Rauch b5c3730dcd 2002-09-13 Oliver Rauch <Oliver.Rauch@rauch-domain.de>
* backend/umax-scanner.c, backend/umax.conf
          doc/descriptions/umax.desc:
          added Linotype Hell SAPHIR3 as supported scanner
2002-09-13 14:27:32 +00:00
Oliver Rauch 2865131e36 2002-09-11 Oliver Rauch <Oliver.Rauch@rauch-domain.de>
* doc/descriptions/umax.desc: corrected some urls
2002-09-11 20:38:56 +00:00
Henning Geinitz 2887a1a24f Added fb636u as unsupported. Added status information. 2002-09-11 19:02:29 +00:00
Frank Zago da6aa74692 Added threshold option for b&w. 2002-09-07 21:32:25 +00:00
Marcio Teixeira 1a62a5f0f0 Removed the "Incompatible" note for the UMAX2200US since it is supported by the "umax" backend. 2002-09-07 18:37:15 +00:00
Oliver Rauch 19b99d7197 updated umax.desc 2002-09-07 16:32:11 +00:00
Oliver Rauch 5e2087a43f Update of umax.desc: PowerLook 2100XL stable 2002-09-07 16:13:42 +00:00
Oliver Rauch 08bc05d7cd 2002-09-07 Oliver Rauch <Oliver.Rauch@rauch-domain.de>
* backend/umax.c, umax.h, umax-scanner.c, umax.conf
          doc/descriptions/umax.desc
          Update to sane-umax build 36
2002-09-07 10:11:17 +00:00
Matthew Duggan 45bf928a3c * doc/sane-canon_pp.man doc/descriptions/canon_pp.desc:
Added FB320P to supported scanners after report of successful test.
  Added FB310P and FB610P to desc as specifically not supported yet.
2002-09-03 15:20:49 +00:00
Peter Kirchgessner ea238f9bb7 Peter Kirchgessner: applied patch by David Paschal to remove PTAL-support 2002-09-01 17:47:37 +00:00
Matthew Duggan f0722f0d5c Added support for FB620P to canon_pp backend. 2002-09-01 08:57:34 +00:00
Frank Zago 1e2e1f8cd2 backend integrated. 2002-08-31 15:46:31 +00:00
Frank Zago c8b46ff4f7 Added vm3510. 2002-08-31 02:54:15 +00:00
Rene Rebe c67286adee Commited the latest avision backend. 2002-08-30 09:21:51 +00:00
Henning Geinitz 6fdbf3b2fe Minor fixes and updates for the new .desc file format. 2002-08-29 20:12:44 +00:00
Henning Geinitz 8b0a038f61 Big clean up of Video for Linux backend. Removed old unused stuff from qcam
and others including unused options and variables concerning direct port
access. Removed wcam license (no "substantial portions of code" are used any
more). Removed unuesed headers. Made lots of global variables local. Lots of
checks for null pointer dereferences and errors when opening files or using
ioctl/mmap. Added option to select grey or color mode. Added support for
different channels. Fixed lots of options.  Made sure ioctls are only used
when necessary.  Used vendor == "Noname".  Added ??? comments for suspicious
code.  Lots of minor fixes and cleanup. Added version number: 1.0-2.
2002-08-29 19:34:53 +00:00
Frank Zago 88bda0db33 Increased version number. 2002-08-23 01:37:14 +00:00
Frank Zago 6259eb59d9 Added 3 new (untested) scanners. 2002-08-23 01:15:42 +00:00
Andras Major 29b7b4d674 coolscan2 update to 0.1.7 2002-08-21 23:36:00 +00:00
Gerhard Jaeger 28edd2af4d Major update. Better support for LM983x based devices. 2002-08-16 11:43:30 +00:00
Peter Kirchgessner 36a0e0d332 Peter Kirchgessner: Use Hewlett-Packard instead of HP 2002-07-31 17:22:42 +00:00
Frank Zago f532671b2a New description. 2002-07-26 04:02:51 +00:00
Matthew Duggan db89d5be3b * src/canon_pp.c: Now uses mm instead of pixel measurements, better behaved
in xsane etc as a result.
* src/canon_pp.h: Tweaked up max buffer size to size avaialable in hardware.
* doc/descriptions/canon_pp.desc: increment version no.
2002-07-25 17:45:29 +00:00
Henning Geinitz 2c16e3308b Added option invert-endianess to test 16 bit modes.
Henning Meier-Geinitz <henning@meier-geinitz.de>
2002-07-24 19:57:56 +00:00
Kazuya Fukuda c27627281c Remove unsupported scanner from nec.desc 2002-07-24 14:16:20 +00:00
Peter Fales 9d4f88844d Comment out :interface line ing gphoto2.desc 2002-07-23 18:34:51 +00:00
Stéphane Voltz 8bd54e3f28 - tagged Astra 610P as unsupported 2002-07-23 05:26:15 +00:00
Matto Marjanovic 1e36da44df * doc/descriptions/microtek.desc:
Updated (status keywords, mostly).
	* backend/microtek.c:
	* backend/microtek.h:
	  Replaced fprintf()/printf() with various DBG() statements.
	  Removed #include <stdio.h>!
	  Eliminated a few "unused parameter" compiler warnings.
	  Updated the copyright date.
	  Bumped version up to lucky 0.13.0
2002-07-22 19:53:08 +00:00
Chris Pinkham 1d07be6938 2002-07-22 Chris Pinkham <cpinkham@infi.net>
* doc/descriptions/artec.desc: Changed status of AT6 model to alpha.
      Deleted entries for USB & parallel port scanners which are
      unsupported.
2002-07-22 16:37:39 +00:00
Matthew Duggan 0deefcffb9 doc/descriptions/canon_pp.desc: Added "N640P ex" model to supported
scanners after report of successful test. Also, "EPP" really should
have been "ECP".
2002-07-22 16:22:35 +00:00
Henning Geinitz 3c506cae68 Updated and added more examples.
Henning Meier-Geinitz <henning@meier-geinitz.de>
2002-07-21 18:38:34 +00:00
Oliver Rauch 4adeccbc5f 2002-07-19 Oliver Rauch <Oliver.Rauch@rauch-domain.de>
* doc/descriptions/umax.desc: added per backend status
2002-07-19 20:55:50 +00:00
Henning Geinitz c95e463805 Added manufacturer comment in mustek_usb.desc. Changed brightness to
threshold. Fixed some warnings. Really check the status in usb_low_open.
Henning Meier-Geinitz <henning@meier-geinitz.de>
2002-07-17 17:33:25 +00:00
Frank Zago 6d8ecefe87 Updated descriptions. 2002-07-16 02:53:00 +00:00
Frank Zago b52fc64f44 Added new status field for each scanners. 2002-07-16 02:34:11 +00:00
Henning Geinitz bfafe4e3be Added missing space in ":new :yes" line.
Henning Meier-Geinitz <henning@meier-geinitz.de>
2002-07-14 18:40:23 +00:00
Simon Munton 76f6c5c80f updated pie.desc description file 2002-07-13 21:26:16 +00:00
Max Vorobiev 5a0e8da59a Added new:yes value indicator 2002-07-13 15:15:59 +00:00
Frank Zago 73b66eb2cd Added new untested status to untested scanners. KVSS25D has been confirmed to work out of the box. 2002-07-13 05:05:54 +00:00
Oliver Schwartz 1d1c4d1d8d SnapScan backend 1.4.15 2002-07-12 23:29:11 +00:00
Frank Zago 09ac7f1e3b Changed backend status. 2002-07-12 23:20:47 +00:00
Max Vorobiev 8e22ffc8c2 State changed from 'new' to 'alpha' 2002-07-12 19:57:54 +00:00
Karl Heinz Kremer a2a6322a7f Added :status lines to the scanner entries 2002-07-09 02:25:19 +00:00
Karl Heinz Kremer 436e3858e3 Fixed typo in URL. 2002-07-09 02:20:14 +00:00
Abel Deuring 97ac2221a7 * doc/descriptions/sharp.desc: Added ":status" lines
to the scanner entries

Abel
2002-07-08 22:10:39 +00:00
Henning Geinitz 999d535f7e Updated concerning model status.
Henning Meier-Geinitz <henning@meier-geinitz.de>
2002-07-08 20:23:18 +00:00
Henning Geinitz 52eaab2258 No bugs for quite some time, changed status to stable (knocking on wood).
Updated comments.
Henning Meier-Geinitz <henning@meier-geinitz.de>
2002-07-08 20:03:57 +00:00