* backend/pnm.c: Fixed three segfaults due to buffer overruns:
maximum length of filename wasn't checked; maximum length in
sane_read wasn't always checked; ppm_type wasn't always set in
getparmfromfile. Added some checks for safety and removal of
warnings. Added DBG lines for every SANE API call.
* TODO: Added entries about the backend:devicename issue. Add a
comment about fronends not to crash when length is -1. Added entry
about sane-pie. Added point about fronends not checking if too
much data is delivered with sane_read.
* PROJECTS: Added entry about sane-pie.
* backend/mustek.*: Update to Mustek backend 1.0-97. This is a
development version and is only tested for three-pass scanners.
Added support for Paragon 1200 SP Pro and ScanExpress A3 SP.
Removed detection of " C04" and " C12" (don't seem to exist).
Changed SCSI request scheme. Sane_read can read more than 4096
bytes from pipe. Minimum dpi is 30 now. Fixed LD correction for
Paragon 1200SP 1.06 and 1.11. Read SCSI buffer into big block and
do LD after that for Paragon one-pass scanners. New option
"blocksize" in mustek.conf. Better detection of the scanner type
(three-pass, Paragon I, ...). Fixed possible segmentation faults
in Paragon 600 II N LD code, scsi_sense_wait_ready and
sense_handler. Decreased maximum scan size of Paragon 800 II
SP. For three-pass scanners: fixed stop_scan and speed code, scan
area is in pixels now, added RGB brightness and contrast, use
+-100% for brightness and contrast. Return SANE_STATUS_CANCELLED
when scan was cancelled. Option "force backtracking" is enabled by
default, "scan speed" is set to "fastest". Added option
"force-warn" for mustek.conf. Rewrote halftone mode. Better error
handling and more debug output.
* TODO: Clarified point about image data polarity. Moved point about
xscanimage not updating the progress bar for 3pass scanners to
frontend section. Removed umax entry in "frontends". Removed entry
about alpha channel (was added to LEVEL2 file).
* LEVEL2: Add point about image data polarity.
* frontend/scanimage.c: Removed some warnings.
- Added support for flatbed HP OfficeJets
- (PK) fix problem with cancel preview
hp-backend V 0.91, V 0.90, 02-Sep-2000, PK:
- fix timing problem between killing child and writing to pipe
- change fprintf(stderr,...) to DBG
- change include <sane..> to "sane.." in hp.h
- change handling of options that have global effects.
i.e. if option scanmode is received (has global effect),
all options that "may change" are send to the scanner again.
This fixes a problem that --resolution specified infront of
--mode on command line of scanimage was ignored.
NOTE: This change does not allow to specify --depth 12 infront of
--mode color, because --depth is only enabled with --mode color.
- add depth greater 8 bits for mode grayscale
- add option for 8 bit output but 10/12 bit scanning
* TODO: Updated. Added entries for viceo backend and addition to hp
backend. Updated entries about the include issue. Added point about
additional options for pnm backend, install problem of libsane.la,
and some build problems and the --without-x problem. Some more
details for detecting older SANE versions.
* LEVEL2: Added entry about sending messages from backend to frontend.
Removed entry about image polarity.
* backend/mustek.c backend/mustek.h backend/mustek.CHANGES
backend/mustek.desc: Update to Mustek backend 1.0-99. Better
transparency adapter support for ScanExpress scanners. Changed
color support for ScanExpress scanners (faster at some resolutions
now). Paragon 1200 SP color mode should work now without garbage at
the end of an image. Some bugfixes. Details in
backend/mustek.CHANGES.
* tools/find-scanner.c: Explicitly state that find-scanner won't
find non-SCSI scanners.
* doc/scanimage.man: Add examples for SANE device names.
* frontend/scanimage.c: Output message when no devices are found.
Add example for devicename to --help message. Print warning
when a Unix devicename is used instead of a SANE device. Removed
compiler warning.
* TODO: Removed entries about the fgets and include issues in
umax. Removed entries about scanimage device name
documentation. Added a point about xscanimage problems with the
new GIMP API.
* backend/mustek.* doc/sane-mustek.man: Update to Mustek backend
1.0-98. Fixed segmentation fault in sane_init. Enabled double
buffering. Clear inquiry buffer before using. Paragon 1200 SP now
uses LD_BLOCK color correction. Removed LD MFS (wasn't used
anymore). Fix sane_cancel for Paragon series II scanners. Fix
halftone and grain for Paragon series II scanners. Backtracking is
used automaticly by all scanners now. Some safety checks, code
cleanup and more debug output. Details are in
backend/mustek.CHANGES.
* backend/mustek.*: Update to Mustek backend 1.0-97. This is a
development version and is only tested for three-pass scanners.
Added support for Paragon 1200 SP Pro and ScanExpress A3 SP.
Removed detection of " C04" and " C12" (don't seem to exist).
Changed SCSI request scheme. Sane_read can read more than 4096
bytes from pipe. Minimum dpi is 30 now. Fixed LD correction for
Paragon 1200SP 1.06 and 1.11. Read SCSI buffer into big block and
do LD after that for Paragon one-pass scanners. New option
"blocksize" in mustek.conf. Better detection of the scanner type
(three-pass, Paragon I, ...). Fixed possible segmentation faults
in Paragon 600 II N LD code, scsi_sense_wait_ready and
sense_handler. Decreased maximum scan size of Paragon 800 II
SP. For three-pass scanners: fixed stop_scan and speed code, scan
area is in pixels now, added RGB brightness and contrast, use
+-100% for brightness and contrast. Return SANE_STATUS_CANCELLED
when scan was cancelled. Option "force backtracking" is enabled by
default, "scan speed" is set to "fastest". Added option
"force-warn" for mustek.conf. Rewrote halftone mode. Better error
handling and more debug output.
* TODO: Clarified point about image data polarity. Moved point about
xscanimage not updating the progress bar for 3pass scanners to
frontend section. Removed umax entry in "frontends". Removed entry
about alpha channel (was added to LEVEL2 file).
* LEVEL2: Add point about image data polarity.
* frontend/scanimage.c: Removed some warnings.
Man page and mustek.desc now list all the known scanner names
Added maintainer infos to AUTHORS and mustek.c; web page link to mustek.desc and man page
* backend/umax.c, bachend/umax-scanner.c, backend/umax.desc,
doc/umax/sane-umax-config-doc.html, doc/umax/umax.CHANGES,
doc/sane-umax.man:
update to sane-umax-1.0 build 30:
- added EDGE KTX-9600US as supported scanner
- Changing scansource does not change lower left selection
edge if not necessary
* backend/umax*: bugfixes:
* bugfix for DOR:
- bottom-right edge keeps in position if possible when DOR is switched on
* bugfix for Astra 610S color mode:
- scale_y is set to 0.5 if y_resolutions is smaller than optical_res/2
this does fix the color scan problems for Astra 610S.
Not tested for Astra 600S.
* Changelog: added snapshot marker 2001-06-17
* backend/umax*: bugfixes:
- removed "#include <assert.h>" from umax.c: assert() is never called
- bugfix for 3 pass scanning:
reposition_scanner is called in sane_start for 2nd and 3rd pass of 3 pass scan
- bugfix for UTA and DOR geometry offsets