Henning Geinitz 9634e891f8 Added more options for batch-scanning (patch from Caskey Dickson
<caskey-lists-sane-devel@technocage.com>).
Henning Meier-Geinitz <henning@meier-geinitz.de>
2001-06-02 22:54:55 +00:00
Henning Geinitz 7efa6198f0 Added sane(7) to SEE ALSO.
Henning Meier-Geinitz <henning@meier-geinitz.de>
2001-05-24 18:42:45 +00:00
Henning Geinitz 30b517b433 2001-04-13 Henning Meier-Geinitz <hmg@gmx.de>
* PROJECTS TODO: Added entry about E3 USB chipset.
	* backend/dll.c backend/dll.desc: New version is 1.0.5. Version and
	  PACKAGE_VERSION is printed with debug level set to 1 or higher.
	  The version numbers of all backends that are loaded are printed
	  at debug level 3 or higher. Print error if backend with wrong
	  major version number is loaded. Some standardization changes
	  concerning the DBG messages.
	* backend/net.c backend/net.desc: New version is 1.0.5. Version and
	  PACKAGE_VERSION is printed with debug level set to 1 or higher.
	  Some standardization changes concerning the DBG messages.
	* backend/pnm.c: Return SANE_INFO_RELOAD_PARAMS even if the pnm
	  file doesn't exist or can't be loaded (from mh <crapsite@gmx.net>).
	* doc/backend-writing.txt: Added AUTHORS to the list of things that
	  should be updated when including a new backend. Added points about
	  avoiding printf and exit in backends.
	* doc/releases.txt: New file. This text summarizes some points to
	  pay attention to when a new release of sane-backends is made.
	  Additions and corrections are appreciated.
	* doc/scanimage.man: Add some more information about the -V option.
	* frontend/scanimage.c: The option -V now also prints the version of
	  the backend (ususally dll).
2001-04-13 17:04:51 +00:00
Henning Geinitz da39a39f83 2000-11-24 Henning Meier-Geinitz <hmg@gmx.de>
* AUTHORS: Removed authors of xscanimage and xcam (now in
	  sane-frontends).
	* README.unixware2, README.unixware7: X-frontends are no longer
	  included. Removed comments and sourcecode of "rev" (not supported/used
	  in backends/Makefile anymore).
	* sane.lsm: X-frontends are no longer included. Used blanks instead of
	  tabs.
	* doc/scanimage.man: Removed links to backends, added generic link
	  instead.
	* doc/.cvsignore frontend/.cvsignore: X-frontends are no longer included.
2000-11-24 22:21:32 +00:00
Jochen Eisinger 201b9d662d 2000-11-24 Jochen Eisinger <jochen.eisinger@gmx.net>
* doc/scanimage.man doc/saned.man: updated description of password
	  file
	* sanei/sanei_auth.c frontend/saned.c frontend/scanimage.c: replaced
	  index() by strchr(). Changed style of password file
	* backend/net.c: the net backend now prepends net:host: to the
	  resource before calling the auth_callback function
2000-11-24 15:05:22 +00:00
Jochen Eisinger 3e4ae9dce7 2000-11-20 Jochen Eisinger <jochen.eisinger@gmx.net>
* configure configure.in: Added test for /dev/urandom and
	  index() in string.h or strings.h
	* backend/net.c: Fixed SANE_NET_AUTHORIZE call handling
	* doc/net.tex: Clarified definition of SANE_NET_AUTHORIZE, added
	  definition of MD5 authorization
	* doc/sane.tex: Upgraded to version 1.0.2, changed definition of
	  SANE_MAX_USERNAME_LEN & SANE_MAX_PASSWORD_LEN to 128 chars
	* doc/saned.man: added description of SANE_CONFIG_DIR/saned.users
	* doc/scanimage.man: added description of ~/.sane/pass and
	  --accept-md5-only
	* frontend/saned.c: implemented user authorization on a per backend
	  basis
	* frontend/scanimage.c: fixed bug (option -b wasn't present)
	  implemented auth_callback
	* include/sane/sane.h: changed definition of SANE_MAX_USERNAME_LEN &
	  SANE_MAX_PASSWORD_LEN to 128 chars
	* lib/Makefile.in sanei/Makefile.in: updated Makefiles
2000-11-20 18:49:26 +00:00
Henning Geinitz a466f9f914 2000-10-03 Henning Meier-Geinitz <hmg@gmx.de>
* tools/find-scanner.c: Explicitly state that find-scanner won't
 	  find non-SCSI scanners.
	* doc/scanimage.man: Add examples for SANE device names.
	* frontend/scanimage.c: Output message when no devices are found.
	  Add example for devicename to --help message. Print warning
	  when a Unix devicename is used instead of a SANE device. Removed
	  compiler warning.
	* TODO: Removed entries about the fgets and include issues in
 	  umax. Removed entries about scanimage device name
 	  documentation. Added a point about xscanimage problems with the
 	  new GIMP API.
	* backend/mustek.* doc/sane-mustek.man: Update to Mustek backend
 	  1.0-98. Fixed segmentation fault in sane_init. Enabled double
 	  buffering. Clear inquiry buffer before using. Paragon 1200 SP now
 	  uses LD_BLOCK color correction. Removed LD MFS (wasn't used
 	  anymore). Fix sane_cancel for Paragon series II scanners. Fix
 	  halftone and grain for Paragon series II scanners. Backtracking is
 	  used automaticly by all scanners now. Some safety checks, code
 	  cleanup and more debug output. Details are in
	  backend/mustek.CHANGES.
2000-10-03 16:24:25 +00:00
Petter Reinholdtsen b4a1a513c9 Merge devel (v1.0.3) into head branch. 2000-08-12 15:11:46 +00:00
Petter Reinholdtsen 30ab5e718a Initial revision 1999-08-09 18:06:01 +00:00