Wykres commitów

778 Commity (14fbbc3066bd7b51529ad921464c26dd44af2328)

Autor SHA1 Wiadomość Data
Rene Rebe 2f8f90a79a Update to the latest Avision backend release. It includes feature
and stability improvements and bug fixes. The sane man-page now
mentions that the avision backend supports more than the AV 630 CS ...
2003-02-16 17:35:05 +00:00
Karl Heinz Kremer e1b2d70a16 Moved sanei_usb_init() to sane_init(). Thanks to Ron Cemer for the patch. 2003-02-15 21:09:47 +00:00
Karl Heinz Kremer aae28825db Fix problem with "usb <vendor> <product> syntax in config file 2003-02-15 18:18:58 +00:00
Peter Fales fefaf27951 1) Don't coredump if gphoto2.conf file is missing. 2) Don't require
a speed to be set in gphoto2.conf if the serial port is not used.
2003-02-12 02:54:47 +00:00
Peter Fales 333db710cd Added a (commented out) entry for gphoto2 in dll.conf 2003-02-12 02:16:42 +00:00
Peter Kirchgessner 71103c85e6 Fix a problem with ifdef/ifndef for threads 2003-02-11 22:34:11 +00:00
Stéphane Voltz b2370c178e - fixed a big bug related to color plane sync, which gave blur
pictures at > 75 dpi
        - changed version number
2003-02-09 08:26:00 +00:00
Peter Fales 54d9e2729d Fixes for Irix from Andrea Suatoni 2003-02-09 03:23:59 +00:00
Henning Geinitz 5b79536901 Fixed resolutions for BearPaw 1200 TA. Increase the lowest black for CCD
coarse calibration. Adjusted internal gamma correction.  CCD scanners use
color mode for coarse+quality cal now. Preview isn't always in 8 bit mode now
(can be selected by option). Upper and lower limits for coarse calibration are
unified now. Added options for adjusting gain and offset.
2003-02-05 16:02:45 +00:00
Peter Kirchgessner 216c5cec42 Add OS/2-support for hp-backend 2003-02-02 17:03:36 +00:00
Gerhard Jaeger 7d13614480 *** empty log message *** 2003-01-31 12:36:44 +00:00
Jochen Eisinger 641376bc7f 2003-01-25 Jochen Eisinger <jochen.eisinger@gmx.de>
* backend/mustek_pp.c: fixed some character encoding issues in
	  debug messages
2003-01-26 13:45:33 +00:00
Jochen Eisinger 3c30357f9d 2003-01-24 Jochen Eisinger <jochen.eisinger@gmx.de>
* backend/mustek_pp_ccd300.c: continued on the CCD low-level driver.
	  There is still some bug in it, that keeps it from actually scanning
	  something...
2003-01-25 20:04:52 +00:00
Henning Geinitz 85dddb6ca0 Use "Color pattern" consistantly. 2003-01-24 14:00:11 +00:00
Henning Geinitz f25fd9c455 Minor conversion fixes (from Andrea Suatoni <a.suatoni@telefonica.net>). 2003-01-24 13:52:52 +00:00
Gerhard Jaeger ee94f0caf1 Minor fixes and prototype description updates, code cleanup, doc update. 2003-01-24 11:44:04 +00:00
Andras Major 36a01d3b84 *** empty log message *** 2003-01-23 23:41:21 +00:00
Eddy De Greef 2fe806cb51 Compile warning fix and minor debug message fixes. 2003-01-21 21:45:00 +00:00
Karl Heinz Kremer 0f701cfaa2 Added information about MFDs (multi-functional devices, scanners with
printers) to documentation and sane_usb.c file.
2003-01-19 19:17:29 +00:00
Henning Geinitz 6d895dbc7b Removed wrong "untested" flag from Mustek AE USB and Lexmark X70/X73 scanners. 2003-01-18 11:46:15 +00:00
Frank Zago 4c36caa5ac *** empty log message *** 2003-01-17 01:56:01 +00:00
Henning Geinitz af90832aee Bugfix for the X12USL(solved problems >600dpi), one for lineart mode with a
6400XL and one for Scanmaker 5 (crashes at sendgamma). From Karsten Festag
<karsten.festag@gmx.de>.
2003-01-16 22:07:18 +00:00
Jochen Eisinger 48d3828a13 2003-01-13 Jochen Eisinger <jochen.eisinger@gmx.de>
* backend/mustek_pp*, backend/Makefile: merged all mustek_pp
	  related files into one compile unit and removed illegal symbols
2003-01-13 19:49:47 +00:00
Nathaniel Rutman b1d4dce599 calibration and gamma correction enhancements by M.Reinelt <reinelt@eunet.at> 2003-01-13 03:01:04 +00:00
Jochen Eisinger 47e110e473 2003-01-12 Jochen Eisinger <jochen.eisinger@gmx.de>
* doc/sane-mustek_pp.man, doc/descriptions/mustek_pp.desc,
	  backend/mustek_pp*: replaced the old mustek_pp backend with
	  version 12-alpha. This version fully supports CIS scanners but
	  removes support for 600dpi CCD scanners and the 300dpi CCD
	  support isn't yet working. In contrary to the old backend, this
	  version is based on information provided by Mustek. For now,
	  the backend exports lots of illegal symbols, this will be fixed
	  before code freeze. Also the .desc file is empty and will be updated
	  soon.
	* AUTHORS: added Eddy De Greef who wrote the CIS hardware driver part
2003-01-12 19:44:26 +00:00
Abel Deuring 1f7adcf0d1 backend/sharp.*: fixed a segfault, when the SCAN command returned
an error; optional "relaxed" handling of transparency unit errors.

Abel
2003-01-12 14:17:19 +00:00
Henning Geinitz be735bc16b OPT_THRESHOLD fix. Avoid using "_" in option names. Set more options in
microtek2.conf to on by default. From Karsten Festag <karsten.festag@gmx.de>.
2003-01-11 22:15:14 +00:00
Henning Geinitz 1652b580a4 Removed hardcoded option size. 2003-01-10 17:15:12 +00:00
Gerhard Jaeger 8ba08fdfca Update to version 0.45, added some new models and support for libusb. 2003-01-10 13:32:11 +00:00
Ulrich Deiters ee88748aa6 fixed uninitialized variable; made SANE pay attention to return status of
do_focus() and do_gamma()
2003-01-10 07:11:33 +00:00
Peter Fales fa0abed1cf Fix OS/2 build error 2003-01-10 01:09:12 +00:00
Henning Geinitz 9f0d82980b Updated manpage and .desc concerning Lexmark X70. Updated manpage concerning
kernel 2.4.21-pre3 containing the 1-endpoint fix. Fixed A3 USB resolution
setting. Updated A3 USB margins (Pedro Morais <morais@inocam.com>). Added
detection of Genius Colorpage Vivid3x.  It's unknown if it works. Updated
.desc file. Don't print calib line warnings by default.
2003-01-09 18:05:01 +00:00
Henning Geinitz a50e314cbe Improved support for Scanmaker X12USL. Alpha support for Scanmaker
9800XL. Some bugfixes. (From Karsten Festag <karsten.festag@gmx.de>).
2003-01-09 00:40:45 +00:00
Oliver Schwartz 42f2440739 Update to snapscan backend 1.4.18 2003-01-08 21:45:28 +00:00
Oliver Rauch 0b681c7438 update to sane-umax build 39 2003-01-07 18:18:46 +00:00
Peter Fales d8410c5ad2 backend/dc210.c, backend/dc240.c - use a more portable way to generate
serial port "breaks"
2003-01-07 15:43:41 +00:00
Matthew Duggan e9220432d0 2003-01-07 Matthew Duggan <stauff1@users.sourceforge.net>
* backend/canon_pp-dev.c: Improve/fix detection logic.
* doc/descriptions/canon_pp.desc: Bump version number.
2003-01-07 05:14:28 +00:00
Peter Fales 58993e7e36 Irix fixes from mailing list 2003-01-07 01:15:16 +00:00
Peter Fales 5e464b1576 Fix compiler warning 2003-01-07 01:10:44 +00:00
Peter Fales f37d33ccaa Fix logic bugs from mailing list 2003-01-05 19:54:49 +00:00
Stéphane Voltz 34ba009415 - made /dev/parport0 the default device for scanning
- small picture quamity improvement
2003-01-05 07:37:54 +00:00
Karl Heinz Kremer fa68479dcb Removed one '//' comment. 2002-12-31 21:20:33 +00:00
Henning Geinitz f63abd633e Make sure that frontend bugs concerning the select fd are detected. 2002-12-30 13:44:27 +00:00
Henning Geinitz b97a0721b5 Updated ScanExpress 2400 USB values. Added implementation of gt6801 lamp
control for CCD scanners. Added flag for SE 2400 USB, added some quirks in
gt68xx_gt6801.c. Fixed gt68xx_gt6801 -> lamp control. Adjusted Plustek 1248U
geometry and afe values. CCD gross calibration changed: start with the default
value from module struct. Is faster now for most cases. Only 2.5 mm of
calibration for GT-6801 scanners. Added "afe" option for gt68xx.conf for
selecting default afe values. Removed AFE and exposure SANE options. Added
documentation for afe option in gt68xx.conf. New version: 1.0-35.
2002-12-30 13:05:24 +00:00
Henning Geinitz 503f6e61ae Backends shouldn't be linked to sanei_config2 if they aren't also linked to
sanei_scsi. sanei_config2 needs sanei_scsi.
2002-12-30 12:59:10 +00:00
Karl Heinz Kremer e9f5b82656 Added option to display short resolution list to support displays (e.g.
Sony Vaio PictureBook) that cannot show the complete list.
2002-12-29 02:40:35 +00:00
Henning Geinitz 7f699acfe3 Coarse calibration for first scan only" is off by default now. Added gamma
table factor option (SANE_CAP_EMULATED). Setup gamma to 2.0 by default.  Fixed
(hopefully) sigpipe when cancelling. No geometry quantization anymore (not
necessary). Plustek 1248U: do linemode for every resolution, fix color
correction. Added comments for every Model member in gt68xx_devices.  Added
Plustek UT16B and Genius Vivid3x to .desc. Added implementation for inverted
offset for CCD scanners. Added Mustek ScanExpress 2400 USB. Well, at least
it's detected. Added NEW marker to .desc.
2002-12-08 21:00:31 +00:00
Karl Heinz Kremer 820ac413e7 Fixed problem with dropout color 2002-12-07 12:00:15 +00:00
Peter Kirchgessner 35f5cdf6e0 Add option to work around "error during device I/O" 2002-12-06 20:14:36 +00:00
Peter Kirchgessner 41cdb74d97 Workaround problem with Buslogic SCSI driver in hp-backend 2002-12-06 19:46:39 +00:00