m. allan noah 03c5a9ee44 * backend/canon_dr.[ch], backend/canon_dr-cmd.h, doc/sane-canon_dr.man,
backend/canon_dr.conf.in, doc/descriptions/canon_dr.desc:
- New Canon DR-series backend v3
- support all modes and resolutions of DR-9080C
- advanced options (MF detection, compression) not yet supported
- other larger models believed similar, smaller ones unknown
* doc/descriptions/unsupported.desc: remove Canon DR-series machines
2008-11-10 03:36:11 +00:00
m. allan noah 8eaa9c65e4 fujitsu backend v82
- improved front-side endorser vpd detection
- send scanner_control_ric during sane_read of each side
- add fi-6770A and fi-6670A USB ID's
2008-11-01 01:34:18 +00:00
Nicolas Martin 173e05ffd1 TPU scan 48 bits at 4800 dpi, fix MP810 at 2400 dpi. Updated docs. 2008-10-25 15:22:04 +00:00
m. allan noah a65329e472 * doc/descriptions/fujitsu.desc: backend v81, fix fi-6240 usb id 2008-10-21 17:52:11 +00:00
Nicolas Martin f573865c33 ifaddrs.h header check and increase backend version number 2008-10-18 22:26:57 +00:00
Nicolas Martin 391a6b4549 Added Canon's BJNP network protocol support, fix an ADF issue, updated doc and headers 2008-10-14 19:48:59 +00:00
m. allan noah 56ae50027a * doc/descriptions/fujitsu.desc, doc/sane-fujitsu.man: backend v80 2008-10-10 00:51:31 +00:00
Nicolas Martin 1aa1677ef2 Changes for ADF simplex and duplex scan, MP970 4800 dpi and TPU scan. 2008-10-05 20:42:19 +00:00
m. allan noah 48e23ca24e * doc/descriptions/fujitsu.desc, backend/fujitsu.conf.in,
backend/fujitsu.[ch], backend/fujitsu-scsi.h: backend v79
- add usb ids for several models
- print additional hardware capability bits
- detect front-side endorser
- disable endorser-side controls if only one side installed
- add quirks for fi-6x70
2008-10-02 04:03:31 +00:00
Gerhard Jaeger 98de411d6c Added entry for OpticSlim 2400plus 2008-10-01 11:44:54 +00:00
Gerhard Jaeger bb2e71643b Removed entry for UT12 devid 0x0013
Cleanup
2008-10-01 10:36:03 +00:00
Gerhard Jaeger 24f5d10762 Added entry for UT12 devid 0x0013 2008-10-01 10:35:36 +00:00
m. allan noah 0bbf8bac04 2008-09-25 m. allan noah <kitno455 a t gmail d o t com>
* backend/epjitsu.[ch], backend/epjitsu-cmd.h: backend v 13, 14 and 15:
        - add working page-height control
        - add working brightness, contrast and threshold controls
        - add disabled threshold curve and geometry controls
        - move initialization code to sane_get_devices, for hotplugging
        - support S300 on USB power
        - support S300 225x200 and 600x600 scans
        - support for automatic paper length detection (parm.lines = -1)
        - expose hardware buttons/sensors as options for S300
        * doc/descriptions/epjitsu.desc: change S300 status to good
2008-09-25 03:15:49 +00:00
Nicolas Martin 5ab0b2024c Changes for MP970 (to be continued), add MX7600 pid (untested yet). 2008-09-13 12:32:52 +00:00
Nicolas Martin 286dbd885d Doc update, CCD sensors white lines padding fix, enhance scan area adjustments. 2008-09-07 19:08:25 +00:00
m. allan noah 72894d1e98 * doc/descriptions/fujitsu.desc: mark fi-6230 and fi-6240 complete 2008-08-27 17:50:47 +00:00
m. allan noah 08d54b457a * backend/fujitsu.c, doc/descriptions/fujitsu.desc: backend v78
- recent model names (fi-6xxx) dont end in 'C'
- simplify flatbed area overrides
- call scanner_control to change source during sane_start
2008-08-26 17:04:30 +00:00
Gerhard Jaeger 8e75357955 Added entry for Strobe XP100 2008-08-25 20:29:56 +00:00
Gerhard Jaeger 8968a4a58a Removed entry for Strobe XP100 2008-08-25 20:29:24 +00:00
m. allan noah ad02a8f1ac set lots of scanners to complete status :) 2008-08-24 02:40:54 +00:00
m. allan noah 852411f3f4 * backend/fujitsu.[ch]: backend v76
- add independent maximum area values for flatbed
- override said values for fi-4220C, fi-4220C2 and fi-5220C
* doc/descriptions/fujitsu.desc: bump version, add 2 untested scanners
2008-08-14 03:56:17 +00:00
Rene Rebe b975ac1fcd * backend/fujitsu.c, backend/fujitsu.conf.in,
doc/descriptions/fujitsu.desc: backend v75
	- added fi-6230 ID, updated fi-6130, fi-6230 status
2008-08-07 08:21:51 +00:00
m. allan noah ea2a506cba fujitsu backend v73
- add fi-6130 usb ID
- correct overscan dimension calculation
- provide correct overscan size overrides for fi-5110C and fi-4x20C2
- fi-5750C can't handle 10 bit LUT via USB
2008-07-27 23:29:12 +00:00
m. allan noah 887b008e7c * AUTHORS: Earle has commit perms
* doc/descriptions/unsupported.desc: add Lexmark X7170
* include/sane/sanei_config.h: remove typedef so doxygen will shutup
2008-07-26 05:34:28 +00:00
m. allan noah 4f4ce809ba * backend/fujitsu.[ch]: backend v72,
- use mode_sense to determine background color support
- remove fi-5900 background color override
2008-07-14 00:59:26 +00:00
Nicolas Martin b17fddd55b A few changes for ADF source scanning, updated MX850 description. 2008-07-05 12:42:53 +00:00
m. allan noah 40e5aaa7fe * backend/fujitsu.[ch], backend/fujitsu-scsi.h: backend v68,
- add halftone type and pattern options
 - support M3097G with IPC and CMP options via modified VPD response
* doc/descriptions/fujitsu.desc, doc/sane-fujitsu.man: backend v68,
 - manpage cleanup
2008-07-02 20:43:49 +00:00
m. allan noah f3ed5342cc backend version 65, add endorser support, add quirks for fi-4990 2008-06-25 02:30:54 +00:00
Ilia Sotnikov 249681dbc6 + Added support for HP ScanJet 4570c (thanks to Markham Thomas) 2008-06-19 11:03:49 +00:00
m. allan noah ad779e0865 backend version 64,
use model and serial to build sane.name (idea from Ryan Duryea),
 allow both serial_name and device_name to sane_open scanner,
 simulate missing VPD data for M3097G, probe scanner for color
 interlacing mode instead of hardcoding, other minor cleanups
2008-05-30 08:47:38 +00:00
m. allan noah 2016e8f019 backend version 1.0.62, begin sane 1.1.0 compliance 2008-05-21 02:27:14 +00:00
m. allan noah f6f4de5d5d * doc/descriptions/cardscan.desc, doc/descriptions/epjitsu.desc,
doc/descriptions/hp3900.desc, doc/descriptions/hp5590.desc,
  doc/descriptions/hpljm1005.desc, doc/descriptions/hs2p.desc:
  remove 'new' tag from sane 1.0.19 backends
* doc/descriptions/fujitsu.desc, backend/fujitsu.conf.in:
  add fi-5530C2 usb ID
* backend/cardscan.c: correct version number
* backend/epjitsu.conf.in: improved firmware directions
* backend/fujitsu.[ch]: update to backend v 1.0.61
2008-05-16 02:31:57 +00:00
Nicolas Martin a2933d5207 USB IDs updates in imageClass backend (pixma), by Dennis Lou. 2008-05-07 06:51:01 +00:00
Stéphane Voltz 1eb416ba47 - description update for untested HP4400 model
- 150 dpi mode fix for HP4470 models sold with XPA
2008-05-06 20:00:32 +00:00
Nicolas Martin 3f86915941 Description and man updates for PIXMA MX300. 2008-05-05 21:20:50 +00:00
Nicolas Martin 9ee0385130 Code cleanup patch to imageClass backend (pixma) by Dennis Lou. 2008-05-04 17:34:20 +00:00
m. allan noah 16f5a83f8d fujitsu: support new fi-6x20
epjitsu: mention new S300M
2008-04-23 01:55:34 +00:00
Nicolas Martin 8e5710ca1c Updated release version of pixma backend. 2008-04-22 19:30:14 +00:00
Nicolas Martin fcc26f51e1 Update descriptions for Canon ImageCLASS series MFPs. 2008-04-21 19:24:46 +00:00
m. allan noah 39458249b5 backend version 1.0.58:
- page code 32 is not color interlacing, rename to 'unknown'
- increase number of bytes in response buffer of init_ms()
- protect debug modification code in init_ms() if NDEBUG is set
- proper async sane_cancel support
- re-enable JPEG support
- replace s->img_count with s->side
- sane_get_parameters(): dont round up larger than current paper size
- sane_start() rewritten, shorter, more clear
- return values are SANE_Status, not int
- hide unused functions
2008-04-20 01:31:29 +00:00
Nicolas Martin 983e8c0eeb Update for MP970 (yet for color scan, all resolutions) and bug fix for MP220 at 1200 dpi (reported to work OK) 2008-04-15 21:27:34 +00:00
Nicolas Martin d9d44cbe72 Added a tempo before failing in NO PAPER in ADF scan, declared MX850, changed MP970 to Generation 3. 2008-04-02 20:13:48 +00:00
Stéphane Voltz b85ec879da - rts8891 backend inclusion 2008-03-22 14:33:36 +00:00
Nicolas Martin 52ec47a434 Added Canon PIXMA MX700, declared MX300 and MX310, and updated some descriptions. 2008-03-16 16:33:53 +00:00
Stéphane Voltz 5be6af9c72 - removed scanners supported by the lexmark backend from
unsupported.desc
	- umax_pp small copyright refresh
2008-03-02 15:01:13 +00:00
Gerard Klaver 430d0d77ed Update with Dexxa 4800 support information 2008-03-01 12:32:02 +00:00
Nicolas Martin bf6f5936e8 Update for PIXMA MP140 now working with pixma backend 2008-02-24 09:24:49 +00:00
Nicolas Martin 5ff80f5f36 Changed MP140 comment to not working yet 2008-02-22 21:43:46 +00:00
Nicolas Martin 2738f8f5b8 Changed name: MultiPass MP710 and MP740 to Pixma MP710 and MP740 2008-02-18 20:49:46 +00:00
Nicolas Martin a1265b6dad New models changes:
- added: Pixma MP210, MP470, MP520, MP610
 - added: MultiPASS MP710
 - declared untested: MP140, MP220, MultiPASS MP740
 - declared experimental and untested: MP970
Bugs and fixes
 - multipage documents scan no more fails with non-ADF MPs
 - IO Fail bug when scanning large pages e.g. with Xsane
 - implement send_time message form MP710, MP730 family
 - run indent -gnu on all pixma_* source files.
2008-02-17 15:49:43 +00:00