Wykres commitów

13 Commity (08fb0db49eff0188389301d62832d69fea52895e)

Autor SHA1 Wiadomość Data
Henning Geinitz e891ffb8ab Added Plustek OpticPro S(T)12 (product id 0x040b). Mostly untested. Print warmup
message 5 seconds after starting the warm-up.
2006-01-02 16:59:03 +00:00
Henning Geinitz 7d332297b6 Silenced non-fatal warnings/error messages. Several fixes for avoiding
freezes/timeouts after cancelling a scan. Several fixes for warming up of
lamp. Decreased scan width of Plustek OpticPro 1248U.
2005-12-09 11:55:11 +00:00
Henning Geinitz fb40be18dc Added support for Plustek OpticSlim M12 (untested). Based on patch from Gerhard
Jaeger <gerhard@gjaeger.de>. Fixed gt68xx homepage links in man page. Changed
minimum version of libusb to 0.1.8.
2005-09-29 18:22:30 +00:00
Henning Geinitz 872c187d42 Fixed segfault that may happen with Mustek ScanExpress A3 USB. 2005-09-18 10:48:18 +00:00
Henning Geinitz 93d43e0be8 Increased number limit of scanners that can work with this backend to 50. Added
support for Genius ColorPage Vivid 1200 X (untested).
2005-08-20 17:54:34 +00:00
Henning Geinitz b19e6c5262 Fixed the problem concerning scanning on *BSD. Scanning only worked once (bug
#300597). Fixed compilation warnings.
2005-08-18 19:26:09 +00:00
Henning Geinitz aaf3c69627 Testing commit messages. 2005-07-21 18:02:41 +00:00
Henning Geinitz 67eb059c49 Testing commit mails. 2005-07-21 17:55:50 +00:00
Henning Geinitz 38cc925c4b Changed resolution from 75 to 100 dpi and changed 16 bit/color to 12 based on a
user report for the Visioneer OneTouch 7300. Updated .desc. Moved check for
stable lamp to its own function. Mustek ScanExpress A3 USB: Use CIS
calibration. Use lamp warmup. Fixed CCD on GT6801 scanning (color scanning was
broken due to a change in motormode_2.
2005-07-10 20:58:58 +00:00
Henning Geinitz 6fd1ee367e Start exposure with the settings from the scanner entry. CIS
Calibration and exposure uses a broader spectrum now. Expsoure
	  limit is increased to 50 loops. Genius Vivid 4x is reported to
	  work so the UNTESTED label is removed now. Visioneer 7300 is
	  reported to work so the UNTESTED label is removed now. Genius
	  ColorPage Vivid 1200XE: Removed UNTESTED label. Fixed
	  resolutions. Adjusted margins. Fixed color order. Fixed
	  linedistance. Adjusted AFE. Mustek ScanExpress 1248 UB: Fixed
	  margins. Adjusted AFE. Adjusted exposure. Adjusted
	  gamma. Changed status to "complete". Mustek BearPaw 2400 CU
	  Plus: Adsusted exposure and AFE parameters. Hopefully stripes
	  and similar trouble are gone now. Mustek BearPaw 1200 CU:
	  Increased exposure to avoid vertical lines. Updated manual page.
2005-05-29 19:58:56 +00:00
Henning Geinitz 7d0d083b8d Mustek BearPaw 1200 CU Plus model 0x21b works now. Fixed firmware and offset
settings. Calibration is not completely ok yet, however.  Code cleanup for
setup_scan (only one function for all chipsets).  Simplified line mode/pixel
mode setting Updated TODO.  Mustek BearPaw 2448 TA Plus is now only "basic". Too
much trouble for "good".  Removed option "fast preview". By default for preview
mode 8 bits/pixel are used.  Fixed indentation.  Full scan really scans from y=0
on gt6816 scanners now.
2005-05-20 17:21:56 +00:00
Henning Geinitz ea9ad9a396 Plustek OpticSlim 2400: Fixed list of resolutions. That fixed the
preview. Removed "untested" warning. Adjusted scan area.  Updated gt68xx.TODO.
Find firmwares independent of capitalization (bug #301580).
2005-05-07 17:16:30 +00:00
Henning Geinitz 99d1bc9aab New file. Lots of bugs and missing features for the gt68xx backend. 2004-06-18 09:45:50 +00:00