Wykres commitów

2965 Commity (08ce23f36a062a1a4eaa425ba0936de6a1f103e1)

Autor SHA1 Wiadomość Data
Rolf Bensch afc84646c7 fixed button support 2013-01-18 12:11:31 +01:00
Nils Philippsen defdc1ab5c umax: initialize reader_pid early in sane_start()
This avoids that subsequent errors followed by do_cancel() attempt to
phtread_cancel() an invalid thread (which may cause a crash).
2013-01-16 12:06:09 +01:00
Rolf Bensch da2937dbb5 new scanner Canon i-SENSYS MF6680dn 2013-01-14 15:44:46 +01:00
Rolf Bensch 320b2c5582 new scanner Canon i-SENSYS MF5880dn 2013-01-14 15:25:45 +01:00
Rolf Bensch 580b55cb19 new scanner Canon i-SENSYS MF4550d 2013-01-14 14:21:58 +01:00
Rolf Bensch b4bb0062c5 fix for broken post_process_image_data() 2013-01-11 16:37:00 +01:00
Louis Lagendijk bf0758bc8b Changed the pixma bjnp implementation to use its own debug environment
variable (SANE_DEBUG_BJNP) so debugging for the bjnp protocol and the
backend proper can be controlled independently.
Updated manpage for sane-pixma to document the above changes as well
as the changed scannner buttjn options and the fact the bjnp protocol
has added support for IPv6
2013-01-10 21:10:41 +01:00
Louis Lagendijk 3276babdec Added optional support in saned for systemd socket activation. This will allow for
using backend debugging using SANE_DEBUG_xxx to be used for saned controlled
scanning when using socket activation. When only the socket is received we
use the existing code path.
2013-01-10 20:59:26 +01:00
Rolf Bensch d7d4437550 formatted white space 2013-01-10 16:48:01 +01:00
Rolf Bensch 9dd8f8ea74 fix for broken tpu scan 2013-01-08 10:44:25 +01:00
Paul Newall 1be4eb8264 kodakaio - detecting end of paper or padding when using adf is now an option 2013-01-03 21:23:20 +00:00
Paul Newall 6c43f2df2a kodakaio adf now detects end of paper 2012-12-31 20:13:32 +00:00
Rolf Bensch 4dd4f4f98e new scanner Canon Pixma MG4200 2012-12-31 20:04:19 +01:00
Alex Belkin 51a235bcfd Usb Id for Samsung CLX-3300 Series, reported by Jarkko A-L. 2012-12-28 10:23:07 +04:00
Paul Newall a8faa35b7b kodakaio fix bug to allow adf to scan more than 1 sheet with net connection 2012-12-23 21:23:43 +00:00
Louis Lagendijk f57a193198 Merge branch 'master' of ssh://git.debian.org/git/sane/sane-backends 2012-12-18 16:24:41 +01:00
Louis Lagendijk 8c7931cf89 Fixed issue where UDP ports were not closed in pixma_bjnp.c 2012-12-18 16:23:27 +01:00
Nils Philippsen a1273d1c65 coolscan3: average multiple samples
(ported from coolscan2, commit 4126b6796d)
2012-12-17 21:35:16 +01:00
Nils Philippsen 2bc59796ca coolscan3: set multi-sampling on scanner
(ported from coolscan2, commit 2385657904)
2012-12-17 21:35:12 +01:00
Nils Philippsen 6589dbd5c0 coolscan3: only offer samples-per-scan for devices supporting it
(ported from coolscan2, commit ed9ac6f15d)
2012-12-17 21:35:08 +01:00
Nils Philippsen 82139b0823 coolscan3: add samples-per-scan option
(ported from coolscan2, commit 121afa695b)
2012-12-17 21:30:13 +01:00
Nils Philippsen 4126b6796d coolscan2: average multiple samples 2012-12-13 13:13:36 +01:00
Nils Philippsen 2385657904 coolscan2: set multi-sampling on scanner 2012-12-13 13:13:36 +01:00
Nils Philippsen ed9ac6f15d coolscan2: only offer samples-per-scan for devices supporting it 2012-12-13 13:13:36 +01:00
Nils Philippsen 121afa695b coolscan2: add samples-per-scan option 2012-12-13 13:13:36 +01:00
Paul Newall fc4f54bd55 ESP2170 gets adf and adf y now 11.3 2012-12-09 23:29:07 +00:00
Stéphane Voltz bd44b058a0 gamma handling refactor
- use arrays instead of gamma tables
- send_gamma_table does only send gamma table and doesn't
  create ramp if no custom gamma
- create a default gamma table with gamma value from device
  description
2012-12-09 15:45:59 +01:00
Stéphane Voltz 3af19cf7ef enable GAIN4 by default 2012-12-09 15:45:59 +01:00
Rolf Bensch 667a5d81c0 Canon Pixma MG3100 reported as working 2012-12-07 20:07:23 +01:00
Rolf Bensch 3dc944302a new scanner Canon imageCLASS MF4430 2012-12-07 19:44:44 +01:00
Rolf Bensch e62bffb0a8 pixma version 0.17.1 2012-12-07 19:36:52 +01:00
Rolf Bensch 82eb323bfd Canon Pixma MX890 reported as working 2012-12-07 19:29:58 +01:00
Stéphane Voltz c3dbbf495b activate binary logging for gl124 2012-12-05 21:56:06 +01:00
Stéphane Voltz c3ebf3171d issue parking command as early as possible 2012-12-05 21:56:06 +01:00
m. allan noah f7fe42c33e canon_dr v40: DR-9050, 7550, 6050 and 3010 support 2012-11-28 21:51:13 -05:00
m. allan noah ed7a5f227d use automake instead of autoreconf so libtoolize is not run 2012-11-28 21:51:12 -05:00
m. allan noah 9b142567fa Revert "forgot to do autoreconf"
This reverts commit aa6f185452.
2012-11-28 21:51:12 -05:00
Paul Newall aa6f185452 forgot to do autoreconf 2012-11-28 22:11:04 +00:00
Paul Newall f31002ed06 kodakaio changed to use avahi for net discovery 2012-11-28 21:35:36 +00:00
Stéphane Voltz dd2448ddec rts8891 improved version
- fixed batch scan issues
- 600 dpi color mode OK for type 1 sensor
2012-11-24 08:34:28 +01:00
Stéphane Voltz 1211286c12 register setting improvment 2012-11-22 21:08:16 +01:00
Stéphane Voltz a2983760cc create separate regsiters set up functions to allow unit testing 2012-11-13 22:08:12 +01:00
Stéphane Voltz eb9af2d4a3 fix typo in shading target set up 2012-11-11 08:06:34 +01:00
Stéphane Voltz cf9f70564e gl124 based scanners calibration improvement
- move to calibration area before doing led calibration
- increase white target for shading data
- fix parking issue for scan at higher dpi than 600
2012-11-11 07:52:59 +01:00
Stéphane Voltz e5b886cb76 add optional doxygen documentation generation for the genesys backend 2012-11-02 21:46:44 +01:00
Louis Lagendijk d9e7dc5412 backend/pixma.c backend/pixma.h backend/pixma_mp150.c backend/pixma_mp810.c
backend/pixma_sane_options.c backend/pixma_sane_options.h:
- added new options:
     original (type of original to be scanned)
     target (action to be perfomed as target of the scan)
  Both these indocators can be returned by the scanner.
  pixma_mp810 can definately return these (e.g. for my MP980)
  I have assumed that the same applies to devices in pixma_mp150.c
  The target used to be returned in button1/2 in bits 0 - 8.
- All button options are now read and cached when any of the options
  are read (SANE_ACTION_GET_VALUE) or SANE_ACTION_SET_VALUE is used
  on option button_update.
  When reading an option again, the status of all options is re-read.
- Added a dummy info field that is used in case info is NULL
  as this is a valid input
2012-10-31 12:40:07 +01:00
Louis Lagendijk 240ea344b8 pixma_gen_options.py: Changed so the formatting of the files it
creates match the formatting of pixma.c (replaced \t at start of
a new line to 2 spaces)
2012-10-31 11:55:03 +01:00
Alex Belkin 01c2562b4c usb id for Samsung SCX-4833FD, reported by Frank Pennycook; description for SCX-3405W working in networking mode, reported by Patrick Mackinlay. 2012-10-29 08:08:57 +04:00
Stéphane Voltz a35050c8bf doxygen fixes 2012-10-24 21:30:17 +02:00
Stéphane Voltz 704c81a019 add experimental Canonscan 8400F support 2012-10-24 21:30:17 +02:00