Wykres commitów

1955 Commity (046441ad6c7b4837601191be4865a851bb03275c)

Autor SHA1 Wiadomość Data
Mike Kelly 0233072a5e Removed a duplicate entry for Avision AV210C2
Removed a duplicate entry for Avision AV210C2 and Regenerated the
description file.
2010-12-23 19:38:07 +09:00
Stéphane Voltz 98c5d9454f LiDE 210 tuning
- dynamic lineart not enabled by default
2010-12-16 22:10:37 +01:00
Stéphane Voltz 35f133c59b add an device entry for LiDE 210 2010-12-15 06:24:55 +01:00
Stéphane Voltz 3d89a6f880 add new gl124 asic
create a place holder for low level commands

move low level functions to genesys_low.c

GL124 progresses

enable genesys_low debug and add DAC for LiDE 110

gl124 WIP
- gl847 cleanups
- genesys_low refactor
- gl124 starting version

GL124 WIP
- read scancnt/fedcnt,valid words coded
- memory layout coded

LiDE110 WIP

GL 124 WIP
- definition and use of get/set double/triple
- define register names

all mods done, ready to test

set fe OK

GL124 WIP : ready to test scans

GL124 WIP

GL124 WIP
- fixed analog fe issue: don't put afe regs in global set

GL124 : first light at 300 dpi

GL124 WIP
- 300 and 600 uncalibrated mostly ok (x coordinate rounding)
- 150 and 75 OK x-wise, y to be solved

solved rounding errors for gl124

re-add 400, 200 and 100 dpi modes

GL124 : tous x dpi OK

before adding line cropping

GL124 : line cropping almost finished

GL124 WIP : working line deletion

compute step rework

GL124 WIP : high speed table for dpi <= 300

move to scan area working

line skipping fix

new slope table for 600 dpi base

geometry and movement tuned

GL124 WIP : shading calibration almost working

working 600 dpi shading

GL124 : working shading calibration for all modes but 1200 dpi

working 1200 dpi shading

beta 1 of GL124 support

last tuning

update genesys.desc for LiDE 110

motor slope and start area tuning

shading coefficient computing clean up

add support for GL124 based CanoScan LiDE 110

feed almost OK up to 300 dpi

feeding is fixed

all issues fixed
2010-12-14 18:23:23 +01:00
Mike Kelly 4fcd69a7da - Added the full range of the HP 8300 series scanners. These scanners are all
the same and already work, but this change will reflect that fact on the
  website.
- Generated a new version of doc/descriptions/avision.desc from avision.c.
2010-12-09 16:25:32 +09:00
Mike Kelly 6a49df4496 - Added Xerox DocuMate262i.
- Generated a new version of doc/descriptions/avision.desc from avision.c.
2010-12-09 16:23:18 +09:00
Mike Kelly 12ce47285d - Fixed what appears to have been a fat-fingered change to the USB id for
the AV610, and added a comment for the @V5100 in avision.c.
- Generated a new version of doc/descriptions/avision.desc from avision.c.
  This restores information lost with my last update.  I've intentionally
  seperated these changes so that they can be more easily understood.
2010-12-09 16:22:03 +09:00
Mike Kelly 1b596780e5 - Removed obsolete file backends/avision.desc (again). It was deleted before,
but somehow got re-added again.
- Generated a new version of doc/descriptions/avision.desc from avision.c.
  This change merely updates the .desc file, the driver code remains unchanged.
2010-12-09 16:19:05 +09:00
Mike Kelly 12930627d3 - Adding myself as maintainer.
- Bumping version number.
2010-12-09 16:12:39 +09:00
Julien BLACHE 8e042230e6 Add SCSI IDs for the Perfection 3200 (GT-9800) via FireWire 2010-12-06 18:03:47 +01:00
m. allan noah 239a2f7c22 Fujitsu backend v104
- never request more than s->buffer_size from scanner
- silence noisy set_window() calls from init_interlace()
2010-11-25 09:43:37 -05:00
m. allan noah 9f15c2534d fujitsu backend v103
- remove compiled-in default config file
- initial support for new fi-6xxx machines
- mark S300M support as good
2010-11-23 16:56:13 -05:00
Olaf Meeuwissen da42dfa8eb Update epkowa.desc for iScan 2.26.1 2010-11-19 18:23:19 +01:00
Stéphane Voltz 4d0cd3c5b1 add -A/--all-options to scanimage for exposing all control options of a
backend
2010-11-06 08:00:37 +01:00
Julien BLACHE 9b229f06b9 Add SCSI IDs for ScanJet 4c 2010-10-31 10:20:53 +01:00
Julien BLACHE 2c69d7c19f Resync xerox_mfp desc file & config file 2010-10-30 14:54:36 +02:00
Julien BLACHE 27b1f42b7f Add Samsung SCX 4824 & 4825FN 2010-10-30 14:47:39 +02:00
Stéphane Voltz 7490f08ee4 update G4010/G4050 status 2010-10-13 06:49:03 +02:00
Alex Belkin 842c98d204 Added Samsung SCX-4500W scan over network support for xerox_mfp backend (by Alexander Kuznetsov).
autoconf and automake reconfigure.
2010-09-30 15:11:56 +04:00
Reinhold Kainhofer 093fff631c Fix SANE_CONFIG_DIR handling, use it for dll.d/; Add sanei_config_get_paths
* include/sane/sanei_config.h sanei/sanei_config.c: Add function
        sanei_config_get_paths to obtain all configuration pathes (from env var
        SANE_CONFIG_DIR and default paths); fix pointers to invalid/freed
        strings when SANE_CONFIG_DIR is set

* backend/dll.c: When searching for the dll.d/ directory, also use
        the SANE_CONFIG_DIR env variable.
2010-09-18 10:35:35 +02:00
Julien BLACHE 2ede166550 Update for iScan! 2.26.0 2010-09-17 19:38:26 +02:00
Alex Belkin 946871bbb3 add Xerox WorkCentre 4118 Series usb id 2010-09-15 19:35:41 +04:00
Stéphane Voltz 5bfb117c93 unsupported.desc update 2010-09-13 21:52:10 +02:00
Stéphane Voltz a8eaac4a8d update HP3690 status to supported 2010-09-13 06:19:47 +02:00
Stéphane Voltz 00574ba699 Merge branch 'genesys' 2010-09-12 21:41:51 +02:00
Stéphane Voltz 09f099ec03 update for new sofware features 2010-09-12 21:40:25 +02:00
Nicolas Martin ea1336e71f pixma: several updates for MP375R, MP390, MP460 and docs by Gernot Hassenpflug.
modified:   ChangeLog
	modified:   backend/pixma_mp150.c
	modified:   backend/pixma_mp730.c
	modified:   doc/descriptions/pixma.desc
	modified:   doc/sane-pixma.man
2010-09-08 22:08:32 +02:00
Nicolas Martin 8b87049970 Merge branch 'master' of ssh://git.debian.org/git/sane/sane-backends 2010-09-05 09:46:20 +02:00
Stéphane Voltz 03adcd25df genesys build 32 update 2010-09-04 07:31:13 +02:00
Nicolas Martin 00bd28bdef pixma: documentation updates for supported devices, as reported by Gernot Hassenpflug 2010-09-02 18:18:53 +02:00
Nicolas Martin 2fccb8ffbe pixma: changes supplied by Gernot Hassenpflug for
- supporting Lineart on several Pixma devices
       - descriptions updates
2010-09-01 21:18:14 +02:00
Stéphane Voltz 889a3585ee support for Panasonic KV-SS080 2010-08-31 22:13:42 +02:00
Alex Belkin 8e3528baab added SCX-4623 usb id 2010-08-10 06:42:40 +04:00
Nicolas Martin 52cd1d7d5b pixma: add support for PIXMA MX870, updated docs.
declared PIXMA MF8030, but not yet working.

	modified:   ChangeLog
	modified:   backend/pixma_imageclass.c
	modified:   backend/pixma_mp150.c
	modified:   doc/descriptions/pixma.desc
	modified:   doc/sane-pixma.man
2010-07-22 07:56:13 +02:00
Julien BLACHE 126c70d616 Add :scsi keyword for the Perfection 2450 connected via FireWire 2010-07-15 18:22:34 +02:00
Alesh Slovak 02cecbd75b Update epkowa.desc for iScan 2.25.0 2010-07-12 12:16:53 +02:00
Nicolas Martin 3b1543faf4 pixma: changes for PIXMA MX350 support, usb and ethernet.
modified:   ChangeLog
	modified:   doc/descriptions/pixma.desc
	modified:   doc/sane-pixma.man
2010-07-04 21:22:00 +02:00
Nicolas Martin bb346c0725 pixma: description update for ImageClass MF6500 series
modified:   doc/descriptions/pixma.desc
2010-07-03 17:38:43 +02:00
Nicolas Martin 5eb30a38c3 pixma: doc update for support to ImageClass MF6550.
modified:   ChangeLog
	modified:   doc/descriptions/pixma.desc
	modified:   doc/sane-pixma.man
2010-07-03 00:03:50 +02:00
Nicolas Martin 75878ea6d6 pixma: thanks to Dan McGee, support for PIXMA MX340
modified:   backend/pixma_mp150.c
	modified:   doc/descriptions/pixma.desc
	modified:   doc/sane-pixma.man
2010-07-01 22:28:11 +02:00
Stéphane Voltz 198eda5cdc Canon LiDE 100/200 support improvments
- add 100, 200 and 400 DPI resolutions
- disable true since it isn't working yet
- man page update
2010-06-18 06:42:44 +02:00
Stéphane Voltz d97638a107 Canon LiDE 200 support up to 1200 DPI 2010-06-15 21:12:32 +02:00
m. allan noah 37eba9dcac add usb ids for SCX-4600 2010-06-15 09:54:27 -04:00
m. allan noah ed434097f7 Two scanners have SCSI interface 2010-06-09 20:04:49 -04:00
m. allan noah 3b84595cf5 Remove models supported by new kvs20xx backend 2010-06-09 19:53:28 -04:00
m. allan noah 4659c56667 correct manpage link 2010-06-09 19:47:04 -04:00
m. allan noah e7efa77aa5 Add new kvs20xx backend from Panasonic, for KV-S202xC and KV-S204xC 2010-06-09 16:31:00 -04:00
Stéphane Voltz a36121c1c3 changelog and doc update for genesys backend 2010-06-03 20:57:06 +02:00
m. allan noah bafdabf031 removed duplicate scanner 2010-05-24 15:43:37 -04:00
m. allan noah 909919d0d5 add Fujitsu fi-5015C 2010-05-24 13:44:15 -04:00