Wykres commitów

16 Commity (042656a0025b5eb1200b39601f01dfdf27960793)

Autor SHA1 Wiadomość Data
Henning Geinitz 4b83c2d24c Added Artec Ultima 2000 e+, Nortek Myscan 1200, NeatReceipts Scanalizer
Professional, Genius Colorpage Slim-1200. Name and email address changes.
2007-08-19 13:30:46 +00:00
Henning Geinitz 7d332297b6 Silenced non-fatal warnings/error messages. Several fixes for avoiding
freezes/timeouts after cancelling a scan. Several fixes for warming up of
lamp. Decreased scan width of Plustek OpticPro 1248U.
2005-12-09 11:55:11 +00:00
Henning Geinitz fb40be18dc Added support for Plustek OpticSlim M12 (untested). Based on patch from Gerhard
Jaeger <gerhard@gjaeger.de>. Fixed gt68xx homepage links in man page. Changed
minimum version of libusb to 0.1.8.
2005-09-29 18:22:30 +00:00
Henning Geinitz b19e6c5262 Fixed the problem concerning scanning on *BSD. Scanning only worked once (bug
#300597). Fixed compilation warnings.
2005-08-18 19:26:09 +00:00
Henning Geinitz 7d0d083b8d Mustek BearPaw 1200 CU Plus model 0x21b works now. Fixed firmware and offset
settings. Calibration is not completely ok yet, however.  Code cleanup for
setup_scan (only one function for all chipsets).  Simplified line mode/pixel
mode setting Updated TODO.  Mustek BearPaw 2448 TA Plus is now only "basic". Too
much trouble for "good".  Removed option "fast preview". By default for preview
mode 8 bits/pixel are used.  Fixed indentation.  Full scan really scans from y=0
on gt6816 scanners now.
2005-05-20 17:21:56 +00:00
Henning Geinitz af58065746 64 bit platform fixes (bug #300799). 2004-10-03 17:34:36 +00:00
Henning Geinitz f7fb0fa2d2 Committed missing file. 2004-09-03 18:08:02 +00:00
Henning Geinitz 75a39c06d7 Updated to backend version 61. Lots of fixes for coarse calibration, scanning
speed and several scanners. For details, see gt68xx.CHANGES.
2004-06-18 09:49:32 +00:00
Henning Geinitz 0ed2b19fd7 Added Mustek BearPaw 2448 TA Plus. Added special command set for Plustek
U16B. Added Plug-n-Scan 2400 M(T) to list of devices. No positive report yet.
Used request for memory writes and reads instead of a fixed value of 0x04. Set
Genius Vivid4x to GT6816. Untested. All changes have not been tested on their
respective scanners yet.  New version: 1.0.50.
2003-11-23 21:14:43 +00:00
Henning Geinitz f206deb849 Fixed compilation bug when debugging is disabled. 2003-10-13 16:57:17 +00:00
Henning Geinitz 0bb508a879 Small requests are done with a response buffer of 8 bytes (instead of 64)
now. Looks like GT-6816 based scanners return 8 bytes if the firmware is
loaded and 64 bytes if it's not loaded. Changed GT-6816 firmware check to
ignore errors from above change. GT-6816 scanners work with the BSDs now (at
least once). Updated manpage concerning the BSDs.
2003-03-06 14:27:54 +00:00
Henning Geinitz 4b00890161 Added Genius Colorpage Vivid3xe. Added request_type and request fields to the
command set. Request is 0x01 or 0x04.
2003-02-27 17:31:52 +00:00
Henning Geinitz 7f699acfe3 Coarse calibration for first scan only" is off by default now. Added gamma
table factor option (SANE_CAP_EMULATED). Setup gamma to 2.0 by default.  Fixed
(hopefully) sigpipe when cancelling. No geometry quantization anymore (not
necessary). Plustek 1248U: do linemode for every resolution, fix color
correction. Added comments for every Model member in gt68xx_devices.  Added
Plustek UT16B and Genius Vivid3x to .desc. Added implementation for inverted
offset for CCD scanners. Added Mustek ScanExpress 2400 USB. Well, at least
it's detected. Added NEW marker to .desc.
2002-12-08 21:00:31 +00:00
Henning Geinitz 089b24e539 Changed 150 to 200 dpi for Mustek BearPaw 2400 TA. Fixed warnings in
gt68xx_low.c. Used DBG instead of XDBG ing gt68xx_low.c.  Minor manpage
fixes. Added man page links to other backends.  gt68xx_low.h: Fixed
__FUNCTION__ bug on non-gcc compilers.  Added more details about the BSDs in
the manpage. Fixed color order for ScanExpress A3 USB.
2002-11-21 22:09:16 +00:00
Henning Geinitz 7b590a0cde Faster AFE calibration. Minor fixes. New version: 1.0-28. 2002-10-31 19:50:44 +00:00
Henning Geinitz 492b63060f Added gt68xx backend for scanners based on the Grandtech GT-6801
and GT-8616 chips like The Mustek BearPaw CU, and TA scanners
and some Artec Ultima 2000 clones.
2002-10-25 12:16:15 +00:00