kopia lustrzana https://gitlab.com/sane-project/backends
spelling fixes for canon_dr backend
rodzic
0e8b1d0e89
commit
fbe99c0914
|
@ -126,9 +126,9 @@
|
|||
- send_panel() can disable too
|
||||
- add cancel() to send d8 command
|
||||
- call cancel() only after final read from scanner
|
||||
- stop button reqests cancel
|
||||
- stop button requests cancel
|
||||
v12 2009-01-21, MAN
|
||||
- dont export private symbols
|
||||
- don't export private symbols
|
||||
v13 2009-03-06, MAN
|
||||
- new vendor ID for recent machines
|
||||
- add usb ids for several new machines
|
||||
|
@ -149,7 +149,7 @@
|
|||
v18 2009-03-21, MAN
|
||||
- rewrite config file parsing to reset options after each scanner
|
||||
- add config options for vendor, model, version
|
||||
- dont call inquiry if those 3 options are set
|
||||
- don't call inquiry if those 3 options are set
|
||||
- remove default config file from code
|
||||
- add initial gray deinterlacing code for DR-2510C
|
||||
- rename do_usb_reset to do_usb_clear
|
||||
|
@ -175,8 +175,8 @@
|
|||
v24 2009-04-02, MAN
|
||||
- fix DR-2510C duplex deinterlacing code
|
||||
- rewrite sane_read helpers to read until EOF
|
||||
- update sane_start for scanners that dont use object_position
|
||||
- dont call sanei_usb_clear_halt() if device is not open
|
||||
- update sane_start for scanners that don't use object_position
|
||||
- don't call sanei_usb_clear_halt() if device is not open
|
||||
- increase default buffer size to 4 megs
|
||||
- set buffermode on by default
|
||||
- hide modes and resolutions that DR-2510C lies about
|
||||
|
@ -206,8 +206,8 @@
|
|||
- merge x and y resolution options into single option
|
||||
- move scan params into two new structs, s->u and s->s
|
||||
- sane_get_parameters() just returns values from s->u
|
||||
- dont call wait_scanner() in object_position()
|
||||
- dont call ssm_*() from option handler
|
||||
- don't call wait_scanner() in object_position()
|
||||
- don't call ssm_*() from option handler
|
||||
- refactor sane_start()
|
||||
- read_from_buffer() can workaround missing res, modes and cropping
|
||||
- set most DR-2xxx machines to use the read_from_buffer workarounds
|
||||
|
@ -318,7 +318,7 @@
|
|||
v51 2015-08-25, MAN (SANE 1.0.25)
|
||||
- DR-C125 does not invert_tly, does need sw_lut
|
||||
v52 2015-11-03, MAN
|
||||
- set can_color=1 by default (recent models dont have 'C' in name)
|
||||
- set can_color=1 by default (recent models don't have 'C' in name)
|
||||
- enable jpeg for DR-6080
|
||||
- add must_downsample and must_fully_buffer
|
||||
- improve dropout option handling
|
||||
|
@ -3019,7 +3019,7 @@ sane_control_option (SANE_Handle handle, SANE_Int option,
|
|||
DBG (20, "sane_control_option: set value for '%s' (%d)\n", s->opt[option].name,option);
|
||||
|
||||
if ( s->started ) {
|
||||
DBG (5, "sane_control_option: cant set, device busy\n");
|
||||
DBG (5, "sane_control_option: can't set, device busy\n");
|
||||
return SANE_STATUS_DEVICE_BUSY;
|
||||
}
|
||||
|
||||
|
@ -3034,7 +3034,7 @@ sane_control_option (SANE_Handle handle, SANE_Int option,
|
|||
return status;
|
||||
}
|
||||
|
||||
/* may have been changed by constrain, so dont copy until now */
|
||||
/* may have been changed by constrain, so don't copy until now */
|
||||
val_c = *(SANE_Word *)val;
|
||||
|
||||
/*
|
||||
|
@ -4259,7 +4259,7 @@ update_i_params(struct scanner *s)
|
|||
*
|
||||
* this will be called between sides of a duplex scan,
|
||||
* and at the start of each page of an adf batch.
|
||||
* hence, we spend alot of time playing with s->started, etc.
|
||||
* hence, we spend a lot of time playing with s->started, etc.
|
||||
*/
|
||||
SANE_Status
|
||||
sane_start (SANE_Handle handle)
|
||||
|
@ -4458,10 +4458,10 @@ sane_start (SANE_Handle handle)
|
|||
}
|
||||
|
||||
/* set clean defaults with new sheet of paper */
|
||||
/* dont reset the transfer vars on backside of duplex page */
|
||||
/* don't reset the transfer vars on backside of duplex page */
|
||||
/* otherwise buffered back page will be lost */
|
||||
/* ingest paper with adf (no-op for fb) */
|
||||
/* dont call object pos or scan on back side of duplex scan */
|
||||
/* don't call object pos or scan on back side of duplex scan */
|
||||
if(s->side == SIDE_FRONT || s->s.source == SOURCE_ADF_BACK || s->s.source == SOURCE_CARD_BACK){
|
||||
|
||||
/* clean scan params for new scan */
|
||||
|
@ -5944,7 +5944,7 @@ calibrate_AFE (struct scanner *s)
|
|||
goto cleanup;
|
||||
}
|
||||
|
||||
/*blast the existing fine cal data so reading code wont apply it*/
|
||||
/*blast the existing fine cal data so reading code won't apply it*/
|
||||
ret = offset_buffers(s,0);
|
||||
ret = gain_buffers(s,0);
|
||||
|
||||
|
@ -6388,7 +6388,7 @@ calibrate_fine (struct scanner *s)
|
|||
goto cleanup;
|
||||
}
|
||||
|
||||
/*blast the existing fine cal data so reading code wont apply it*/
|
||||
/*blast the existing fine cal data so reading code won't apply it*/
|
||||
ret = offset_buffers(s,0);
|
||||
ret = gain_buffers(s,0);
|
||||
|
||||
|
@ -6701,7 +6701,7 @@ gain_buffers (struct scanner *s, int setup)
|
|||
* handle h is a valid handle) but usually affects long-running
|
||||
* operations only (such as image acquisition). It is safe to call
|
||||
* this function asynchronously (e.g., from within a signal handler).
|
||||
* It is important to note that completion of this operaton does not
|
||||
* It is important to note that completion of this operation does not
|
||||
* imply that the currently pending operation has been cancelled. It
|
||||
* only guarantees that cancellation has been initiated. Cancellation
|
||||
* completes only when the cancelled call returns (typically with a
|
||||
|
@ -6727,7 +6727,7 @@ sane_cancel (SANE_Handle handle)
|
|||
|
||||
/* checks started and cancelled flags in scanner struct,
|
||||
* sends cancel command to scanner if required. don't call
|
||||
* this function asyncronously, wait for pending operation */
|
||||
* this function asynchronously, wait for pending operation */
|
||||
static SANE_Status
|
||||
check_for_cancel(struct scanner *s)
|
||||
{
|
||||
|
@ -7520,7 +7520,7 @@ do_usb_clear(struct scanner *s, int clear, int runRS)
|
|||
DBG (15, "do_usb_clear: clear halt\n");
|
||||
ret = sanei_usb_clear_halt(s->fd);
|
||||
if(ret != SANE_STATUS_GOOD){
|
||||
DBG(5,"do_usb_clear: cant clear halt, returning %d\n", ret);
|
||||
DBG(5,"do_usb_clear: can't clear halt, returning %d\n", ret);
|
||||
return ret;
|
||||
}
|
||||
}
|
||||
|
@ -7680,7 +7680,7 @@ get_page_width(struct scanner *s)
|
|||
return s->max_x_fb;
|
||||
}
|
||||
|
||||
/* cant overscan larger than scanner max */
|
||||
/* can't overscan larger than scanner max */
|
||||
if(width > s->valid_x){
|
||||
return s->valid_x;
|
||||
}
|
||||
|
@ -7704,7 +7704,7 @@ get_page_height(struct scanner *s)
|
|||
return s->max_y_fb;
|
||||
}
|
||||
|
||||
/* cant overscan larger than scanner max */
|
||||
/* can't overscan larger than scanner max */
|
||||
if(height > s->max_y){
|
||||
return s->max_y;
|
||||
}
|
||||
|
|
|
@ -20,7 +20,7 @@
|
|||
#option buffer-size 2097152
|
||||
|
||||
#######################################################################
|
||||
# Most scanners dont pad their reads
|
||||
# Most scanners don't pad their reads
|
||||
#option padded-read 0
|
||||
|
||||
#######################################################################
|
||||
|
|
|
@ -304,7 +304,7 @@ struct scanner
|
|||
unsigned char lut[256];
|
||||
|
||||
/* --------------------------------------------------------------------- */
|
||||
/* values used by the software enhancment code (deskew, crop, etc) */
|
||||
/* values used by the software enhancement code (deskew, crop, etc) */
|
||||
SANE_Status deskew_stat;
|
||||
int deskew_vals[2];
|
||||
double deskew_slope;
|
||||
|
|
|
@ -105,7 +105,7 @@ Scanners can be specified in the configuration file in 4 ways:
|
|||
.PP
|
||||
"scsi CANON DR"
|
||||
.RS
|
||||
Requests backend to search all scsi busses in the system for a device
|
||||
Requests backend to search all scsi buses in the system for a device
|
||||
which reports itself to be a scanner made by 'CANON', with a model name
|
||||
starting with 'DR'.
|
||||
.RE
|
||||
|
@ -119,7 +119,7 @@ specify one. Probably should not be used with the other "scsi" line above.
|
|||
.PP
|
||||
"usb 0x04a9 0x1603" (or other vendor/product ids)
|
||||
.RS
|
||||
Requests backend to search all usb busses in the system for a device
|
||||
Requests backend to search all usb buses in the system for a device
|
||||
which uses that vendor and product id. The device will then be queried
|
||||
to determine if it is a Canon scanner.
|
||||
.RE
|
||||
|
|
Ładowanie…
Reference in New Issue