add an OPT_CALIBRATE option
- add an OPT_CALIBRATION option - call gt68xx_sheetfed_scanner_calibrate() when the OPT_CALIBRATE option is setmerge-requests/1/head
rodzic
20dc2ebfe3
commit
fa014b99e7
|
@ -747,6 +747,31 @@ init_options (GT68xx_Scanner * s)
|
|||
s->opt[OPT_BR_Y].constraint.range = &y_range;
|
||||
s->val[OPT_BR_Y].w = y_range.max;
|
||||
|
||||
/* sensor group, mainly for sheet fed scanners calibration
|
||||
* for now */
|
||||
if (s->dev->model->flags & GT68XX_FLAG_HAS_CALIBRATE)
|
||||
{
|
||||
/* sensor/button group */
|
||||
s->opt[OPT_SENSOR_GROUP].name = SANE_NAME_SENSORS;
|
||||
s->opt[OPT_SENSOR_GROUP].title = SANE_TITLE_SENSORS;
|
||||
s->opt[OPT_SENSOR_GROUP].desc = SANE_DESC_SENSORS;
|
||||
s->opt[OPT_SENSOR_GROUP].type = SANE_TYPE_GROUP;
|
||||
s->opt[OPT_SENSOR_GROUP].constraint_type = SANE_CONSTRAINT_NONE;
|
||||
|
||||
/* calibrate button */
|
||||
s->opt[OPT_CALIBRATE].name = "calibrate";
|
||||
s->opt[OPT_CALIBRATE].title = SANE_I18N ("Calibrate");
|
||||
s->opt[OPT_CALIBRATE].desc =
|
||||
SANE_I18N ("Start calibration using special sheet");
|
||||
s->opt[OPT_CALIBRATE].type = SANE_TYPE_BUTTON;
|
||||
s->opt[OPT_CALIBRATE].unit = SANE_UNIT_NONE;
|
||||
s->opt[OPT_CALIBRATE].cap =
|
||||
SANE_CAP_SOFT_DETECT | SANE_CAP_SOFT_SELECT | SANE_CAP_ADVANCED |
|
||||
SANE_CAP_AUTOMATIC;
|
||||
s->val[OPT_CALIBRATE].b = 0;
|
||||
}
|
||||
|
||||
|
||||
RIE (calc_parameters (s));
|
||||
|
||||
DBG (5, "init_options: exit\n");
|
||||
|
@ -1506,7 +1531,7 @@ sane_control_option (SANE_Handle handle, SANE_Int option,
|
|||
SANE_Action action, void *val, SANE_Int * info)
|
||||
{
|
||||
GT68xx_Scanner *s = handle;
|
||||
SANE_Status status;
|
||||
SANE_Status status = SANE_STATUS_GOOD;
|
||||
SANE_Word cap;
|
||||
SANE_Int myinfo = 0;
|
||||
|
||||
|
@ -1705,6 +1730,10 @@ sane_control_option (SANE_Handle handle, SANE_Int option,
|
|||
myinfo |= SANE_INFO_RELOAD_OPTIONS;
|
||||
break;
|
||||
|
||||
case OPT_CALIBRATE:
|
||||
status = gt68xx_sheetfed_scanner_calibrate (s);
|
||||
break;
|
||||
|
||||
default:
|
||||
DBG (2, "sane_control_option: can't set unknown option %d\n",
|
||||
option);
|
||||
|
@ -1720,7 +1749,7 @@ sane_control_option (SANE_Handle handle, SANE_Int option,
|
|||
*info = myinfo;
|
||||
|
||||
DBG (5, "sane_control_option: exit\n");
|
||||
return SANE_STATUS_GOOD;
|
||||
return status;
|
||||
}
|
||||
|
||||
SANE_Status
|
||||
|
|
|
@ -213,6 +213,10 @@ enum GT68xx_Option
|
|||
OPT_BR_X, /* bottom-right x */
|
||||
OPT_BR_Y, /* bottom-right y */
|
||||
|
||||
OPT_SENSOR_GROUP,
|
||||
OPT_CALIBRATE, /* button option to trigger call
|
||||
to sheetfed calibration */
|
||||
|
||||
/* must come last: */
|
||||
NUM_OPTIONS
|
||||
};
|
||||
|
|