kopia lustrzana https://gitlab.com/sane-project/backends
Updated backend list. Added comments for additions to sane.tex. Updated .desc
file bug list. Removed scanimage entries. Added plustek man page issue.DEVEL_2_0_BRANCH-1
rodzic
0703083319
commit
efc86aa2b5
35
TODO
35
TODO
|
@ -1,17 +1,14 @@
|
||||||
TODO (2002-09-01)
|
TODO (2002-09-11)
|
||||||
|
|
||||||
******** todo ********
|
******** todo ********
|
||||||
|
|
||||||
backends
|
backends
|
||||||
--------
|
--------
|
||||||
* Add new backends (+ means: scheduled for version 1.0.9)
|
* Add new backends
|
||||||
- hp4200 http://hp4200-backend.sourceforge.net/
|
- hp4200 http://hp4200-backend.sourceforge.net/
|
||||||
- Genius Vivid Pro USB, Colorado USB 19200, Visioneer OneTouch 7600
|
|
||||||
IBM IdeaScan 2000 USB
|
|
||||||
http://homepages.paradise.net.nz/stevenel/scanner/
|
|
||||||
- Hewlett-Packard ScanJet 3300C / 3400C and 4300C (wip)
|
- Hewlett-Packard ScanJet 3300C / 3400C and 4300C (wip)
|
||||||
http://sourceforge.net/projects/hp3300backend
|
http://sourceforge.net/projects/hp3300backend
|
||||||
|
|
||||||
* All backends should check for TL_X < BR_X and TL_Y < BR_Y to
|
* All backends should check for TL_X < BR_X and TL_Y < BR_Y to
|
||||||
avoid segfaults or even scanner damage. This should NOT be done
|
avoid segfaults or even scanner damage. This should NOT be done
|
||||||
in sane_control_option, it should be possible to temporary set
|
in sane_control_option, it should be possible to temporary set
|
||||||
|
@ -94,25 +91,22 @@ doc
|
||||||
- Add some text about the meaning of bits in 1-bit modes.
|
- Add some text about the meaning of bits in 1-bit modes.
|
||||||
- Define, how to handle SANE_CAP_ADVANCED for groups.
|
- Define, how to handle SANE_CAP_ADVANCED for groups.
|
||||||
- sane_start() can also return SANE_STATUS_INVAL
|
- sane_start() can also return SANE_STATUS_INVAL
|
||||||
|
- sane_set_io_mode: SANE_STATUS_UNSUPPORTED should mean: "The backend does
|
||||||
|
not support the requested I/O mode.". Also explain in more detail that
|
||||||
|
this function must be called after sane_start.
|
||||||
|
- Add a well-known option that represents the status of buttons or some other
|
||||||
|
means to support buttons if this is possible before SANE2. Keep in mind
|
||||||
|
locking issues.
|
||||||
|
|
||||||
* desc files:
|
* desc files:
|
||||||
- Make sure, that the manufacturer (and model) names use the same spelling:
|
- Make sure, that the manufacturer (and model) names use the same spelling:
|
||||||
- hpsj5s (Hewlett-Packard instead of HP)
|
- hpsj5s (Hewlett-Packard instead of HP)
|
||||||
- Check URLs:
|
|
||||||
- umax (http://www.heidelberg-cps.com/ , http://support.umax.com/ ,
|
|
||||||
http://www.umaxweb.com.tw/ )
|
|
||||||
|
|
||||||
- Mark scanners with ":status :untested" if they are untested by the author
|
|
||||||
or users:
|
|
||||||
- canon630u (add 636 as :untested (from manpage)?)
|
|
||||||
|
|
||||||
- Remove unsupported scanners from the list or at least mark them with
|
- Remove unsupported scanners from the list or at least mark them with
|
||||||
":status :unsupported":
|
":status :unsupported":
|
||||||
- mustek_pp
|
- mustek_pp
|
||||||
|
|
||||||
* scanimage:
|
* sane-plustek.man: fix warnings on Debian systems ("sane-plustek contains a pointer loop")
|
||||||
- Add doku for --icc-profile
|
|
||||||
- Add link to gamma4scanimage
|
|
||||||
|
|
||||||
frontends
|
frontends
|
||||||
---------
|
---------
|
||||||
|
@ -129,8 +123,6 @@ frontends
|
||||||
from br-x and br-y but this is wrong for tl-x and tl-y != 0 and for
|
from br-x and br-y but this is wrong for tl-x and tl-y != 0 and for
|
||||||
SANE_UNIT_PIXEL.
|
SANE_UNIT_PIXEL.
|
||||||
|
|
||||||
* scanimage: add option to avoid scanning (for setting options only)
|
|
||||||
|
|
||||||
sanei
|
sanei
|
||||||
-----
|
-----
|
||||||
* sanei_scsi: Think about a completely new interface. Details are in
|
* sanei_scsi: Think about a completely new interface. Details are in
|
||||||
|
@ -188,6 +180,13 @@ misc
|
||||||
|
|
||||||
|
|
||||||
******** done ********
|
******** done ********
|
||||||
|
* scanimage: add option to avoid scanning (for setting options only)
|
||||||
|
* Mark scanners with ":status :untested" if they are untested by the author
|
||||||
|
or users:
|
||||||
|
* scanimage:
|
||||||
|
- Add doku for --icc-profile
|
||||||
|
- Add link to gamma4scanimage
|
||||||
|
* sanei_scsi: Allow changing sg timeout e.g. by environment variables.
|
||||||
* remove ptal support from configure and hp backend
|
* remove ptal support from configure and hp backend
|
||||||
* tools/Makefile.in: -lm dependency doesn't work on OS/2.
|
* tools/Makefile.in: -lm dependency doesn't work on OS/2.
|
||||||
* Fix inclusion of saneopts.??.po in po/. Currently, the "" header is
|
* Fix inclusion of saneopts.??.po in po/. Currently, the "" header is
|
||||||
|
|
Ładowanie…
Reference in New Issue