Added Plustek OpticSlim 1200 to gt68xx backend.

merge-requests/1/head
Gerhard Jaeger 2003-09-30 06:48:42 +00:00
rodzic 6a864e0733
commit dbcb3c853f
7 zmienionych plików z 74 dodań i 11 usunięć

Wyświetl plik

@ -1,10 +1,18 @@
2003-09-30 Gerhard Jaeger <gerhard@gjaeger.de>
* doc/descriptions/unsupported.desc: removed OpticSlim entry
* doc/descriptions/gt68xx.desc doc/gt68xx/gt68xx.CHANGES
doc/sane-gt68xx.man backend/gt68xx.conf: added Plustek OpticSlim entry
* backend/gt68xx_devices.c: added settings for Plustek OpticSlim 1200
2003-09-29 Gerhard Jaeger <gerhard@gjaeger.de>
* doc/sane-plustek.man: minor update
* backend/plustek.c: changed version number, cleanup
* backend/plustek-usb*.c: cleanup
* backend/plustek-pp.*: cleanup
* backend/plustek-share.h backend/Makefile.in: removed, no longer needed
* backend/plustek-share.h: removed, no longer needed
* backend/Makefile.in: removed reference to plustek-share.h
2003-09-28 Henning Meier-Geinitz <henning@meier-geinitz.de>

Wyświetl plik

@ -131,6 +131,10 @@ usb 0x07b3 0x0403
# Plustek OpticPro UT16B
#model "UT16B"
##############################################################################
# Autodetect Plustek OpticSlim 1200
usb 0x07b3 0x0413
##############################################################################
# Autodetect Genius Colorpage Vivid3x
usb 0x0458 0x2011

Wyświetl plik

@ -955,6 +955,54 @@ static GT68xx_Model genius_vivid3xe_model = {
/* mostly untested, based on the Genius Vivid3x */
};
static GT68xx_Model plustek_opticslim1200 = {
"plustek-opticslim-1200", /* Name */
"Plustek", /* Device vendor string */
"OpticSlim 1200", /* Device model name */
"cism216.fw", /* Name of the firmware file */
SANE_FALSE, /* Dynamic allocation flag */
&mustek_gt6816_command_set, /* Command set used by this scanner */
600, /* maximum optical sensor resolution */
1200, /* maximum motor resolution */
600, /* base x-res used to calculate geometry */
600, /* base y-res used to calculate geometry */
1200, /* if ydpi is equal or higher, use linemode */
SANE_FALSE, /* Use base_ydpi for all resolutions */
{600, 300, 150, 75, 50, 0}, /* possible x-resolutions */
{1200, 600, 300, 150, 75, 50, 0}, /* possible y-resolutions */
{16, 8, 0}, /* possible depths in gray mode */
{16, 8, 0}, /* possible depths in color mode */
SANE_FIX (1.0), /* Start of scan area in mm (x) */
SANE_FIX (9.5), /* Start of scan area in mm (y) */
SANE_FIX (218.0), /* Size of scan area in mm (x) */
SANE_FIX (299.0), /* Size of scan area in mm (y) */
SANE_FIX (0.0), /* Start of white strip in mm (y) */
SANE_FIX (140.0), /* Start of black mark in mm (x) */
SANE_FIX (0.0), /* Start of scan area in TA mode in mm (x) */
SANE_FIX (0.0), /* Start of scan area in TA mode in mm (y) */
SANE_FIX (100.0), /* Size of scan area in TA mode in mm (x) */
SANE_FIX (100.0), /* Size of scan area in TA mode in mm (y) */
SANE_FIX (0.0), /* Start of white strip in TA mode in mm (y) */
0, 0, 0, /* RGB CCD Line-distance correction in pixel */
0, /* CCD distcance for CCD with 6 lines) */
COLOR_ORDER_RGB, /* Order of the CCD/CIS colors */
{0x15, 0x09, 0x18, 0x11, 0x16, 0x0c}, /* Default offset/gain */
{0x157, 0x157, 0x157}, /* Default exposure parameters */
SANE_FIX (2.0), /* Default gamma value */
SANE_TRUE, /* Is this a CIS scanner? */
0
};
static GT68xx_USB_Device_Entry gt68xx_usb_device_list[] = {
{0x055f, 0x0218, &mustek_2400ta_model},
{0x055f, 0x0219, &mustek_2400taplus_model},
@ -971,6 +1019,7 @@ static GT68xx_USB_Device_Entry gt68xx_usb_device_list[] = {
{0x07b3, 0x0400, &plustek_op1248u_model},
{0x07b3, 0x0401, &plustek_op1248u_model}, /* Same scanner, different id? */
{0x07b3, 0x0403, &plustek_u16b_model},
{0x07b3, 0x0413, &plustek_opticslim1200},
{0x0458, 0x2011, &genius_vivid3x_model},
{0x0458, 0x2017, &genius_vivid3xe_model},
{0, 0, NULL}

Wyświetl plik

@ -1,5 +1,5 @@
:backend "gt68xx"
:version "1.0-48"
:version "1.0-49"
:manpage "sane-gt68xx"
:url "http://www.meier-geinitz.de/sane/gt68xx-backend/"
:comment "Only the USB scanners mentioned below are supported. For other Mustek BearPaws, look at the Plustek and the MA-1509 backend."
@ -194,6 +194,10 @@
:status :basic
:comment "Works up to 600 dpi, but calibration is slow"
:model "OpticSlim 1200"
:interface "USB"
:status :good
:model "OpticPro U16B"
:interface "USB"
:status :untested

Wyświetl plik

@ -701,13 +701,13 @@
:status :unsupported
:comment "Uses RealTek chipset (RTL8801D)"
:model "OpticPro S12"
:model "OpticPro S12/ST12"
:url "http://www.genesyslogic.com/GL646.htm"
:interface "USB"
:status :unsupported
:comment "Uses the Genesys Logic GL646 chipset."
:model "OpticPro S24"
:model "OpticPro S24/ST24"
:url "http://www.genesyslogic.com/GL646.htm"
:interface "USB"
:status :unsupported
@ -718,11 +718,6 @@
:status :unsupported
:comment "All devices using product ID 0x0001 are not supported, for others see Plustek backend. The older models seem to use a P98003 parallel port ASIC and a GenesysLogic parport-over USB brigde. The P98003 is also used by the P12 and PT12 models."
:model "OpticSlim 1200"
:interface "USB"
:status :unsupported
:comment "Unsupported. No details yet."
:model "OpticPro S28"
:interface "USB"
:status :unsupported

Wyświetl plik

@ -2,6 +2,7 @@ gt68xx.CHANGES -*-text-*-
V 1.0-49 (2003-0?-??)
* Added Settings for Plustek OpticSlim 1200
* Fixed wrong test for allocation in gt68xx.c.
* Added ScanMagic 1200 UB Plus to man page and .desc.

Wyświetl plik

@ -1,4 +1,4 @@
.TH sane-gt68xx 5 "22 Jul 2003" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
.TH sane-gt68xx 5 "30 Sept 2003" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
.IX sane-gt68xx
.SH NAME
sane-gt68xx \- SANE backend for GT-68XX based USB flatbed scanners
@ -59,6 +59,8 @@ Packard Bell Diamond 1200 (Plus)
.br
Plustek OpticPro 1248U
.br
Plustek OpticSlim 1200
.br
RevScan 19200i
.br
Trust Compact Scan USB 19200