kopia lustrzana https://gitlab.com/sane-project/backends
Updated for canon_pp backend. Patch from "Matthew Duggan"
<stauff@guarana.org>. Henning Meier-Geinitz <henning@meier-geinitz.de>DEVEL_2_0_BRANCH-1
rodzic
42f9acfefd
commit
ccfe699a03
3
AUTHORS
3
AUTHORS
|
@ -16,6 +16,7 @@ Backends:
|
||||||
avision: Meino Christian Cramer, Rene Rebe(*)
|
avision: Meino Christian Cramer, Rene Rebe(*)
|
||||||
bh: Tom Martone (*)
|
bh: Tom Martone (*)
|
||||||
canon: Helmut Koeberle, Manuel Panea (*), and Markus Mertinat
|
canon: Helmut Koeberle, Manuel Panea (*), and Markus Mertinat
|
||||||
|
canon_pp: Matthew Duggan (*), Simon Krix
|
||||||
coolscan: Didier Carlier, Andreas Rick (*)
|
coolscan: Didier Carlier, Andreas Rick (*)
|
||||||
dc25: Peter Fales (*)
|
dc25: Peter Fales (*)
|
||||||
dc210: Brian J. Murrell
|
dc210: Brian J. Murrell
|
||||||
|
@ -125,6 +126,7 @@ Manuel Panea <Manuel.Panea@rzg.mpg.de>
|
||||||
Marcio Teixeira <marciot@users.sourceforge.net>
|
Marcio Teixeira <marciot@users.sourceforge.net>
|
||||||
Marian Eichholz <eichholz@computer.org>
|
Marian Eichholz <eichholz@computer.org>
|
||||||
Markus Mertinat <Markus.Mertinat@Physik.Uni-Augsburg.DE>
|
Markus Mertinat <Markus.Mertinat@Physik.Uni-Augsburg.DE>
|
||||||
|
Matthew Duggan <stauff1@users.sourceforge.net>
|
||||||
Matthew Marjanovic <maddog@mir.com>
|
Matthew Marjanovic <maddog@mir.com>
|
||||||
Meino Christian Cramer <mccramer@s.netic.de>
|
Meino Christian Cramer <mccramer@s.netic.de>
|
||||||
Michael Herder <crapsite@gmx.net>
|
Michael Herder <crapsite@gmx.net>
|
||||||
|
@ -142,6 +144,7 @@ Randolph Bentson <bentson@grieg.holmsjoen.com>
|
||||||
Rene Rebe <rene.rebe@gmx.net>
|
Rene Rebe <rene.rebe@gmx.net>
|
||||||
Roger Wolff <R.E.Wolff@BitWizard.nl>
|
Roger Wolff <R.E.Wolff@BitWizard.nl>
|
||||||
Sebastien Sable <Sebastien.Sable@snv.jussieu.fr>
|
Sebastien Sable <Sebastien.Sable@snv.jussieu.fr>
|
||||||
|
Simon Krix <kinsei@users.sourceforge.net>
|
||||||
Simon Munton <simon@munton.demon.co.uk>
|
Simon Munton <simon@munton.demon.co.uk>
|
||||||
Stéphane Voltz <svoltz@wanadoo.fr>
|
Stéphane Voltz <svoltz@wanadoo.fr>
|
||||||
Tom Martone <tom@martoneconsulting.com>
|
Tom Martone <tom@martoneconsulting.com>
|
||||||
|
|
|
@ -47,7 +47,7 @@ SECT5 = sane-abaton.5 sane-agfafocus.5 sane-apple.5 sane-as6e.5 sane-dll.5 \
|
||||||
sane-st400.5 sane-mustek_pp.5 sane-dc210.5 sane-v4l.5 \
|
sane-st400.5 sane-mustek_pp.5 sane-dc210.5 sane-v4l.5 \
|
||||||
sane-snapscan.5 sane-canon.5 sane-coolscan.5 sane-bh.5 sane-dc240.5 \
|
sane-snapscan.5 sane-canon.5 sane-coolscan.5 sane-bh.5 sane-dc240.5 \
|
||||||
sane-umax_pp.5 sane-umax1220u.5 sane-sm3600.5 sane-usb.5 \
|
sane-umax_pp.5 sane-umax1220u.5 sane-sm3600.5 sane-usb.5 \
|
||||||
sane-mustek_usb.5 sane-sceptre.5
|
sane-mustek_usb.5 sane-sceptre.5 sane-canon_pp.5
|
||||||
SECT7 = sane.7
|
SECT7 = sane.7
|
||||||
MANPAGES = $(SECT1) $(SECT5) $(SECT7)
|
MANPAGES = $(SECT1) $(SECT5) $(SECT7)
|
||||||
READMES = README AUTHORS COPYING ChangeLog LEVEL2 LICENSE NEWS PROBLEMS \
|
READMES = README AUTHORS COPYING ChangeLog LEVEL2 LICENSE NEWS PROBLEMS \
|
||||||
|
@ -81,7 +81,7 @@ DISTFILES = Makefile.in backend-writing.txt doxygen-sanei.conf html.sty \
|
||||||
sane-scsi.man sane-sharp.man sane-sm3600.man sane-snapscan.man \
|
sane-scsi.man sane-sharp.man sane-sm3600.man sane-snapscan.man \
|
||||||
sane-st400.man sane-tamarack.man sane-umax.man sane-umax1220u.man \
|
sane-st400.man sane-tamarack.man sane-umax.man sane-umax1220u.man \
|
||||||
sane-umax_pp.man sane-usb.man sane-v4l.man sane.man sane.png \
|
sane-umax_pp.man sane-usb.man sane-v4l.man sane.man sane.png \
|
||||||
sane.tex saned.man scanimage.man sane-sceptre.man \
|
sane.tex saned.man scanimage.man sane-sceptre.man sane-canon_pp.man
|
||||||
|
|
||||||
.PHONY: all clean depend dist distclean html html-man install \
|
.PHONY: all clean depend dist distclean html html-man install \
|
||||||
install-mostang sane-html uninstall
|
install-mostang sane-html uninstall
|
||||||
|
|
|
@ -0,0 +1,33 @@
|
||||||
|
; SANE Backend specification file
|
||||||
|
;
|
||||||
|
; It's basically emacs-lisp --- so ";" indicates comment to end of line.
|
||||||
|
; All syntactic elements are keyword tokens, followed by a string or
|
||||||
|
; keyword argument, as specified.
|
||||||
|
;
|
||||||
|
; ":backend" *must* be specified.
|
||||||
|
; All other information is optional (but what good is the file without it?).
|
||||||
|
;
|
||||||
|
|
||||||
|
:backend "canon_pp" ; name of backend
|
||||||
|
; :manpage "sane-canon"
|
||||||
|
:version "0.1" ; version of backend
|
||||||
|
:status :alpha ; :alpha, :beta, :stable, :new
|
||||||
|
|
||||||
|
:url "http://canon-fb330p.sourceforge.net" ; backend home page
|
||||||
|
|
||||||
|
:devicetype :scanner
|
||||||
|
|
||||||
|
:mfg "Canon" ; name a manufacturer
|
||||||
|
:url "http://www.canon.com/"
|
||||||
|
:model "CanoScan FB330P" ; name models for above-specified mfg.
|
||||||
|
:interface "Parport (EPP)"
|
||||||
|
:comment "1 pass; flatbed scanner"
|
||||||
|
:model "CanoScan FB630P" ; name models for above-specified mfg.
|
||||||
|
:interface "Parport (EPP)"
|
||||||
|
:comment "1 pass; flatbed scanner"
|
||||||
|
:model "CanoScan N340P" ; name models for above-specified mfg.
|
||||||
|
:interface "Parport (EPP)"
|
||||||
|
:comment "1 pass; flatbed scanner"
|
||||||
|
:model "CanoScan N640P" ; name models for above-specified mfg.
|
||||||
|
:interface "Parport (EPP)"
|
||||||
|
:comment "1 pass; flatbed scanner"
|
|
@ -0,0 +1,159 @@
|
||||||
|
.TH sane-canon_pp 5 "30 March 2002"
|
||||||
|
.IX sane-canon_pp
|
||||||
|
.SH NAME
|
||||||
|
sane-canon_pp - SANE backend for Canon Parallel Port flatbed scanners
|
||||||
|
.SH DESCRIPTION
|
||||||
|
The
|
||||||
|
.B sane-canon_pp
|
||||||
|
library implements a SANE (Scanner Access Now Easy) backend that
|
||||||
|
provides access to the following Canon flatbed scanners:
|
||||||
|
.PP
|
||||||
|
.RS
|
||||||
|
CanoScan FB330P
|
||||||
|
.br
|
||||||
|
CanoScan FB630P
|
||||||
|
.br
|
||||||
|
CanoScan N340P
|
||||||
|
.br
|
||||||
|
CanoScan N640P
|
||||||
|
.br
|
||||||
|
.RE
|
||||||
|
.PP
|
||||||
|
No USB scanners are supported and there are no plans to support them in
|
||||||
|
the future. Other projects are working on support for USB scanners. See the
|
||||||
|
.B PROJECTS
|
||||||
|
file for more detail. We cannot add support for the FB310P or FB320P at the
|
||||||
|
moment, but contact us if you have one of these scanners and would really like
|
||||||
|
to help.
|
||||||
|
.PP
|
||||||
|
IMPORTANT: this is alpha code. While we have made every effort to make it as
|
||||||
|
reliable as possible, it will not always work as expected. Feedback is still
|
||||||
|
appreciated. Please send any bug reports to the maintainers as listed on the
|
||||||
|
web page (listed in
|
||||||
|
.B SEE ALSO
|
||||||
|
below).
|
||||||
|
.PP
|
||||||
|
.
|
||||||
|
.PP
|
||||||
|
.SH "DEVICE NAMES"
|
||||||
|
This backend expects device names of the form presented by libieee1284. These names are highly dependant on operating system and version.
|
||||||
|
|
||||||
|
On Linux 2.4 kernels this will be of the form
|
||||||
|
.I "parport0"
|
||||||
|
or older (2.2) kernels may produce names like
|
||||||
|
.IR "0x378"
|
||||||
|
or simply
|
||||||
|
.IR "0"
|
||||||
|
depending on your module configuration. Check the contents of
|
||||||
|
.I /proc/parport
|
||||||
|
if it exists. If you don't want to specify a default port (or don't know
|
||||||
|
its name), the backend should be able to detect which port your scanner is on.
|
||||||
|
|
||||||
|
.SH CONFIGURATION
|
||||||
|
The contents of the
|
||||||
|
.I canon_pp.conf
|
||||||
|
file is a list of options for the driver to use. Empty lines and lines
|
||||||
|
starting with a hash mark (#) are ignored.
|
||||||
|
.PP
|
||||||
|
The supported options are currently
|
||||||
|
.BR ieee1284 ,
|
||||||
|
.BR calibrate ,
|
||||||
|
and
|
||||||
|
.BR force_nibble
|
||||||
|
|
||||||
|
Option
|
||||||
|
.B ieee1284
|
||||||
|
.IR portname
|
||||||
|
defines which port to use. The format of portname is OS dependant, based on
|
||||||
|
the names presented by libieee1284. Please only have one of these lines, or
|
||||||
|
all but one will be ignored.
|
||||||
|
|
||||||
|
Option
|
||||||
|
.B calibrate
|
||||||
|
.IR cal-file
|
||||||
|
.IR [portname]
|
||||||
|
defines which calibration file to use on a per-port basis. If you only have
|
||||||
|
one scanner, the portname argument may be omitted - but be careful as this
|
||||||
|
will cause problems on multi-scanner systems. You may have as many of these
|
||||||
|
lines as you like, as long as each has a unique port name. The tilde (`~')
|
||||||
|
character is acceptable and will be expaned to the value of the HOME environment.
|
||||||
|
|
||||||
|
Option
|
||||||
|
.B force_nibble
|
||||||
|
forces the driver to use nibble mode even if ECP mode is reported to work
|
||||||
|
by libieee1284. This works-around the rare issue of ECP mode being reported to
|
||||||
|
work by the library, then not working.
|
||||||
|
|
||||||
|
.SH TIPS
|
||||||
|
.PP
|
||||||
|
Hit the "Calibrate" button before scanning. It vastly improves the quality
|
||||||
|
of scans.
|
||||||
|
.PP
|
||||||
|
To enable automatic detection of your scanner, uncomment the "canon_pp" line from
|
||||||
|
.I @CONFIGDIR@/dll.conf
|
||||||
|
.PP
|
||||||
|
.SH FILES
|
||||||
|
.TP
|
||||||
|
.I @CONFIGDIR@/canon_pp.conf
|
||||||
|
The backend configuration file (see also description of
|
||||||
|
.B SANE_CONFIG_DIR
|
||||||
|
below).
|
||||||
|
.TP
|
||||||
|
.I @LIBDIR@/libsane-canon_pp.a
|
||||||
|
The static library implementing this backend.
|
||||||
|
.TP
|
||||||
|
.I @LIBDIR@/libsane-canon_pp.so
|
||||||
|
The shared library implementing this backend (present on systems that
|
||||||
|
support dynamic loading).
|
||||||
|
.SH ENVIRONMENT
|
||||||
|
.TP
|
||||||
|
.B SANE_CONFIG_DIR
|
||||||
|
This environment variable specifies the list of directories that may
|
||||||
|
contain the configuration file. Under UNIX, the directories are
|
||||||
|
separated by a colon (`:'), under OS/2, they are separated by a
|
||||||
|
semi-colon (`;'). If this variable is not set, the configuration file
|
||||||
|
is searched in two default directories: first, the current working
|
||||||
|
directory (".") and then in @CONFIGDIR@. If the value of the
|
||||||
|
environment variable ends with the directory separator character, then
|
||||||
|
the default directories are searched after the explicitly specified
|
||||||
|
directories. For example, setting
|
||||||
|
.B SANE_CONFIG_DIR
|
||||||
|
to "/tmp/config:" would result in directories "tmp/config", ".", and
|
||||||
|
"@CONFIGDIR@" being searched (in this order).
|
||||||
|
.TP
|
||||||
|
.B SANE_DEBUG_CANON_PP
|
||||||
|
If the library was compiled with debug support enabled, this
|
||||||
|
environment variable controls the debug level for this backend. Higher
|
||||||
|
debug levels increase the verbosity of the output.
|
||||||
|
|
||||||
|
Example:
|
||||||
|
export SANE_DEBUG_CANON_PP=4
|
||||||
|
.SH BUGS
|
||||||
|
A note on features available in the Windows interface:
|
||||||
|
.TP
|
||||||
|
.B Brightness and Contrast
|
||||||
|
These are not implemented, and probably never will be. These
|
||||||
|
appear to be implented entirely in software. Use GIMP or a similar program if
|
||||||
|
you need these features.
|
||||||
|
.TP
|
||||||
|
.B Descreen Mode
|
||||||
|
This appears on our first analysis to be just oversampling with an
|
||||||
|
anti-aliasing filter. Again, it seems to be implemeneted entirely in
|
||||||
|
software, so GIMP is your best bet for now.
|
||||||
|
.TP
|
||||||
|
.B Gamma Tables
|
||||||
|
This is under investigation, but for now only a simple gamma profile will be
|
||||||
|
loaded.
|
||||||
|
|
||||||
|
.SH "SEE ALSO"
|
||||||
|
sane(7), sane-dll(5)
|
||||||
|
.BR
|
||||||
|
http://canon-fb330p.sourceforge.net/
|
||||||
|
|
||||||
|
.SH AUTHOR
|
||||||
|
This backend is primarily the work of Simon Krix (Reverse Engineering), and
|
||||||
|
Matthew Duggan (SANE interface).
|
||||||
|
.PP
|
||||||
|
Many thanks to Kevin Easton for his comments and help, and Kent A. Signorini
|
||||||
|
for his help with the N340P.
|
||||||
|
|
|
@ -1,4 +1,4 @@
|
||||||
.TH sane 7 "11 Mar 2002"
|
.TH sane 7 "2 Apr 2002"
|
||||||
.IX sane
|
.IX sane
|
||||||
|
|
||||||
.SH NAME
|
.SH NAME
|
||||||
|
@ -153,6 +153,10 @@ scanners. See sane-bh(5) for details.
|
||||||
The canon backend supports the CanoScan 300, CanoScan 600, and CanoScan
|
The canon backend supports the CanoScan 300, CanoScan 600, and CanoScan
|
||||||
2700F SCSI flatbed scanners. See sane-canon(5) for details.
|
2700F SCSI flatbed scanners. See sane-canon(5) for details.
|
||||||
.TP
|
.TP
|
||||||
|
.B canon_pp
|
||||||
|
The canon_pp backend supports the CanoScan FB330P, FB630P, N340P and N640P
|
||||||
|
parallel port scanners. See sane-canon_pp(5) for details.
|
||||||
|
.TP
|
||||||
.B coolscan
|
.B coolscan
|
||||||
This is a SANE backend for Nikon Coolscan film-scanners. See sane-coolscan(5)
|
This is a SANE backend for Nikon Coolscan film-scanners. See sane-coolscan(5)
|
||||||
for details.
|
for details.
|
||||||
|
|
Ładowanie…
Reference in New Issue