kopia lustrzana https://gitlab.com/sane-project/backends
doc: final corrections indicated by translators.
rodzic
7413e3131b
commit
b9edb46542
|
@ -113,7 +113,7 @@ Multiply all exposure times with this value. This allows exposure
|
|||
correction without modifying white balance.
|
||||
.TP
|
||||
.B \-\-load
|
||||
Load the next slide when using the slide loader.
|
||||
Load the next slide when using the slide loader (SF-200 only).
|
||||
.TP
|
||||
.B \-\-eject
|
||||
Eject the film strip or mounted slide when using the slide loader.
|
||||
|
|
|
@ -16,7 +16,8 @@ incorporation in sane-backends.
|
|||
.SH SUPPORTED HARDWARE
|
||||
This version should support models of the Kodak ESP and Hero series, and possibly some
|
||||
Advent AiO scanners. The ESP 5250 and Hero 9.1 were used to develop the backend,
|
||||
but other models may work. Please see the desc file.
|
||||
but other models may work. Please see the supported devices list at
|
||||
.IR http://www.sane-project.org/sane-backends.html#S-KODAKAIO .
|
||||
|
||||
If you have a model not on that list, or reported as 'untested': the best way
|
||||
to determine level of support is to test the scanner directly.
|
||||
|
|
|
@ -10,7 +10,7 @@ provides access to NEC SCSI scanners. This backend should be
|
|||
considered
|
||||
.B alpha-quality
|
||||
software! In the current state it is known to work with PC-IN500/4C
|
||||
scanners. Another MultiReader scanner series is not supported. PC-IN
|
||||
scanners. Other MultiReader scanner series are not supported. PC-IN
|
||||
500/4C and MultiReader scanner are only sold in Japan (except Multi
|
||||
Reader PetiScan).
|
||||
|
||||
|
|
|
@ -40,10 +40,8 @@ that are supported by the scanner dependent on the scanning-mode
|
|||
and other options. Unsupported options are disabled.
|
||||
.PP
|
||||
The following options are supported by the Microtek2-driver:
|
||||
.PP
|
||||
Color, grayscale, halftone and lineart scans.
|
||||
.PP
|
||||
contrast, brightness, control, gamma correction.
|
||||
Also contrast, brightness, and gamma correction.
|
||||
|
||||
.SH "DEVICE NAMES"
|
||||
This backend does not support device names in a standardized form.
|
||||
|
|
|
@ -8,7 +8,7 @@ The
|
|||
library implements a SANE (Scanner Access Now Easy) backend that provides
|
||||
access to several Samsung-based Samsung, Xerox, and Dell scanners.
|
||||
Please see full list of supported devices at
|
||||
http://www.sane\-project.org/sane\-supported\-devices.html
|
||||
.IR http://www.sane\-project.org/sane\-supported\-devices.html .
|
||||
|
||||
.SH CONFIGURATION
|
||||
.TP
|
||||
|
@ -50,7 +50,7 @@ Example:
|
|||
export SANE_DEBUG_XEROX_MFP=4
|
||||
|
||||
.SH LIMITATIONS
|
||||
Multicast autoconfiguration for LAN scanners is not implemented yet. IPv6 addressing never been tested.
|
||||
Multicast autoconfiguration for LAN scanners is not implemented yet. IPv6 addressing has never been tested.
|
||||
|
||||
.SH BUGS AND SUPPORT
|
||||
If you have found a bug or need support please follow open\-source way of acquiring support via
|
||||
|
|
|
@ -288,14 +288,14 @@ The
|
|||
.B \-v
|
||||
or
|
||||
.B \-\-verbose
|
||||
options increase the verbosity of the operation of
|
||||
options increase the verbosity of the output of
|
||||
.B scanimage.
|
||||
The option may be specified repeatedly, each time increasing the verbosity
|
||||
level.
|
||||
.PP
|
||||
The
|
||||
.B \-B
|
||||
option without argument changes the input buffer size from the default 32KB to 1MB. For finer grained control, use
|
||||
option without argument changes the input buffer size from the default 32 KB to 1 MB. For finer grained control, use
|
||||
.B \-\-buffer-size=
|
||||
followed by the number of KB.
|
||||
.PP
|
||||
|
|
Ładowanie…
Reference in New Issue