backend/epson.c:
 - Removed check for '\n' before end of line
 - Free memory malloced in sane_get_devices() in sane_exit() again
 - Check first if the scanner does support the set film type and set
   focus position before the GUI elements are displayed.
 - This caused problems with older (B4 level) scanners when a TPU
   was connected.
DEVEL_2_0_BRANCH-1
Karl Heinz Kremer 2001-05-13 21:18:46 +00:00
rodzic 5c9b31b16f
commit b612995f96
1 zmienionych plików z 33 dodań i 12 usunięć

Wyświetl plik

@ -16,7 +16,8 @@
*/
#define SANE_EPSON_VERSION "SANE Epson Backend v0.2.02 - 2001-03-31"
#define SANE_EPSON_VERSION "SANE Epson Backend v0.2.04 - 2001-05-13"
#define SANE_EPSON_BUILD 204
/*
This file is part of the SANE package.
@ -58,6 +59,14 @@
If you do not wish that, delete this exception notice. */
/*
2000-05-13 Version 0.2.04
Removed check for '\n' before end of line
Free memory malloced in sane_get_devices() in sane_exit() again
2000-04-22 Version 0.2.03
Check first if the scanner does support the set film type
and set focus position before the GUI elements are displayed.
This caused problems with older (B4 level) scanners when a TPU
was connected.
2000-03-31 Version 0.2.02
2001-03-17 Next attempt to get the reported number of lines correct
for the "color shuffling" part.
@ -724,9 +733,16 @@ static SANE_Word * resolution_list = NULL;
*/
/*
*
*
* List of pointers to devices - will be dynamically allocated depending
* on the number of devices found.
*/
static const SANE_Device **devlist = 0;
/*
* Some utility functions
*/
static size_t
@ -2012,7 +2028,7 @@ SANE_Status sane_init (SANE_Int * version_code, SANE_Auth_Callback authorize) {
#endif
if( version_code != NULL)
*version_code = SANE_VERSION_CODE (V_MAJOR, V_MINOR, 0);
*version_code = SANE_VERSION_CODE (V_MAJOR, V_MINOR, SANE_EPSON_BUILD);
/* default to /dev/scanner instead of insisting on config file */
if( (fp = sanei_config_open (EPSON_CONFIG_FILE)))
@ -2025,8 +2041,6 @@ SANE_Status sane_init (SANE_Int * version_code, SANE_Auth_Callback authorize) {
if( line[0] == '#') /* ignore line comments */
continue;
len = strlen (line);
if( line[len - 1] == '\n')
line[--len] = '\0';
if( !len)
continue; /* ignore empty lines */
DBG( 4, "sane_init, >%s<\n", line);
@ -2059,6 +2073,8 @@ void sane_exit ( void) {
free((char *) dev->sane.model);
free(dev);
}
free(devlist);
}
/*
@ -2068,8 +2084,6 @@ void sane_exit ( void) {
SANE_Status sane_get_devices ( const SANE_Device * * * device_list, SANE_Bool local_only)
{
static const SANE_Device **devlist = 0;
Epson_Device *dev;
int i;
@ -3208,10 +3222,17 @@ static void handle_source( Epson_Scanner * s, SANE_Int optindex,
s->hw->x_range = &s->hw->tpu_x_range;
s->hw->y_range = &s->hw->tpu_y_range;
s->hw->use_extension = SANE_TRUE;
/* enable film type option */
s->opt[ OPT_FILM_TYPE].cap |= SANE_CAP_INACTIVE;
s->val[ OPT_FOCUS].w = 1;
s->focusOnGlass = SANE_FALSE;
/* enable film type option if the scanner supports it */
if (s->hw->cmd->set_film_type != 0)
{
s->opt[ OPT_FILM_TYPE].cap |= SANE_CAP_INACTIVE;
}
/* enable focus position if the scanner supports it */
if (s->hw->cmd->set_focus_position != 0)
{
s->val[ OPT_FOCUS].w = 1;
s->focusOnGlass = SANE_FALSE;
}
} else {
s->hw->x_range = &s->hw->fbf_x_range;
s->hw->y_range = &s->hw->fbf_y_range;