kopia lustrzana https://gitlab.com/sane-project/backends
Added manpage for umax_pp (patch from Stphane Voltz
<svoltz@wanadoo.fr>).DEVEL_2_0_BRANCH-1
rodzic
7e66aff707
commit
a9341e05ee
|
@ -0,0 +1,260 @@
|
||||||
|
.TH sane-umax_pp 5 "28 April 2001"
|
||||||
|
.IX sane-umax_pp
|
||||||
|
.SH NAME
|
||||||
|
sane-umax_pp - SANE backend for Umax parallel port flatbed scanners
|
||||||
|
.SH DESCRIPTION
|
||||||
|
The
|
||||||
|
.B sane-umax_pp
|
||||||
|
library implements a SANE (Scanner Access Now Easy) backend that
|
||||||
|
provides access to Umax parallel port flatbed scanners. The
|
||||||
|
following scanners work with this backend:
|
||||||
|
.PP
|
||||||
|
.RS
|
||||||
|
Model:
|
||||||
|
.br
|
||||||
|
--------------------
|
||||||
|
.br
|
||||||
|
Astra 1220P
|
||||||
|
.br
|
||||||
|
HP3200C
|
||||||
|
.br
|
||||||
|
Astra 1600P
|
||||||
|
.br
|
||||||
|
Astra 2000P
|
||||||
|
.br
|
||||||
|
.RE
|
||||||
|
.PP
|
||||||
|
This backend handles 75x75, 150x150, 300x300, 600x600 and 600x1200 dpi scan
|
||||||
|
resolutions, in color and gray levels. There is no lineart mode.
|
||||||
|
.PP
|
||||||
|
These scanners share the same ASIC. Only parts such as CCD and ADC change from
|
||||||
|
one to another. They even all reports being UMAX Astra 1220P via IEEE1284.
|
||||||
|
There isn't direct way to recognize them properly. Under windows, model is
|
||||||
|
set by the driver, regardless of the hardware.
|
||||||
|
.PP
|
||||||
|
The current version of the backend use only EPP mode to communicate with the
|
||||||
|
scanner. PS/2 and SPP mode aren't implemented. It is recommended that you set
|
||||||
|
your parallel port to EPP in BIOS with the current version of this backend.
|
||||||
|
ECPEPP will only work if you use a 2.4 kernel with ppdev support.
|
||||||
|
.PP
|
||||||
|
This backend does support parport sharing only
|
||||||
|
.I
|
||||||
|
if you have a kernel with ppdev support.
|
||||||
|
.I
|
||||||
|
.PP
|
||||||
|
Note that the backend needs to run as root. To allow user access to the scanner
|
||||||
|
run the backend through the network interface (See saned(1) and sane\-net(5)).
|
||||||
|
A more relaxed solution (security wise) is to add sticky bit to the frontend
|
||||||
|
(See chmod(1)).
|
||||||
|
The backend drop root priviledges as soon as it can, right after gaining direct
|
||||||
|
access to IO ports.
|
||||||
|
|
||||||
|
.SH "DEVICE NAMES"
|
||||||
|
This backend expects device names of the form:
|
||||||
|
.PP
|
||||||
|
.RS
|
||||||
|
.I port addr
|
||||||
|
.RE
|
||||||
|
.PP
|
||||||
|
Where
|
||||||
|
.B addr
|
||||||
|
is the base address of the port your scanner is attached to. Known ports are
|
||||||
|
.B 0x378
|
||||||
|
(lp1)
|
||||||
|
.B 0x278
|
||||||
|
(lp2) and
|
||||||
|
.B 0x3BC
|
||||||
|
(lp0). Note that if you are using a Kernel 2.2.x or better and you have only one
|
||||||
|
parallel port this port is named lp0 regardless of the base address. However,
|
||||||
|
this backend requires the base address of your port. If you are not sure which
|
||||||
|
port your scanner is connected to, have a look at your /etc/conf.modules.
|
||||||
|
|
||||||
|
You can rename any device using the
|
||||||
|
.PP
|
||||||
|
.RS
|
||||||
|
.I name devname
|
||||||
|
.br
|
||||||
|
.I model model
|
||||||
|
.br
|
||||||
|
.I vendor vendor
|
||||||
|
.RE
|
||||||
|
.PP
|
||||||
|
options. These options aply to the last port option.
|
||||||
|
|
||||||
|
.SH CONFIGURATION
|
||||||
|
Please make sure to edit umax_pp.conf
|
||||||
|
.B before
|
||||||
|
you use the backend.
|
||||||
|
.PP
|
||||||
|
The contents of the
|
||||||
|
.B umax_pp.conf
|
||||||
|
file is a list of options and device names that correspond to Umax
|
||||||
|
scanners. Empty lines and lines starting with a hash mark (#) are
|
||||||
|
ignored.
|
||||||
|
.PP
|
||||||
|
The height options supported are
|
||||||
|
.BR red-gain ,
|
||||||
|
.BR green-gain ,
|
||||||
|
.BR blue-gain ,
|
||||||
|
.BR red-highlight ,
|
||||||
|
.BR green-highlight ,
|
||||||
|
.BR blue-highlight ,
|
||||||
|
.BR astra ,
|
||||||
|
and
|
||||||
|
.BR buffer .
|
||||||
|
|
||||||
|
Options
|
||||||
|
.B red-gain
|
||||||
|
,
|
||||||
|
.B green-gain
|
||||||
|
and
|
||||||
|
.B blue-gain
|
||||||
|
allow you to adjust the sensitivy of your scanner for the given color. Values
|
||||||
|
range from 0 (lowest gain) to 15 (highest). When all three gains are set to
|
||||||
|
0, the backend does auto gain tuning.
|
||||||
|
.PP
|
||||||
|
|
||||||
|
Options
|
||||||
|
.B red-highlight
|
||||||
|
,
|
||||||
|
.B green-highlight
|
||||||
|
and
|
||||||
|
.B blue-highlight
|
||||||
|
allow you to adjust the highlight of your scanner for the given color. Values
|
||||||
|
range from 0 (lowest highlight) to 15 (highest).
|
||||||
|
.PP
|
||||||
|
|
||||||
|
Option
|
||||||
|
.B astra
|
||||||
|
allows you to change the model of your scanner. Current auto detection is based
|
||||||
|
on side effects on scanning when using 1220P command set on other models, so
|
||||||
|
it may fail on unkown hardware combination. Valid values are 1220, 1600
|
||||||
|
and 2000.
|
||||||
|
.PP
|
||||||
|
|
||||||
|
Option
|
||||||
|
.B buffer
|
||||||
|
allows you to change the size of the scan buffer. The size must be specified in
|
||||||
|
bytes. The default value is 2 megabytes.
|
||||||
|
.PP
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
.SH FILES
|
||||||
|
.TP
|
||||||
|
.I @CONFIGDIR@/umax_pp.conf
|
||||||
|
The backend configuration file (see also description of
|
||||||
|
.B SANE_CONFIG_DIR
|
||||||
|
below).
|
||||||
|
.TP
|
||||||
|
.I @LIBDIR@/libsane\-umax_pp.a
|
||||||
|
The static library implementing this backend.
|
||||||
|
.TP
|
||||||
|
.I @LIBDIR@/libsane\-umax_pp.so
|
||||||
|
The shared library implementing this backend (present on systems that
|
||||||
|
support dynamic loading).
|
||||||
|
|
||||||
|
.SH ENVIRONMENT
|
||||||
|
.TP
|
||||||
|
.B SANE_CONFIG_DIR
|
||||||
|
This environment variable specifies the list of directories that may
|
||||||
|
contain the configuration file. Under UNIX, the directories are
|
||||||
|
separated by a colon (`:'), under OS/2, they are separated by a
|
||||||
|
semi-colon (`;'). If this variable is not set, the configuration file
|
||||||
|
is searched in two default directories: first, the current working
|
||||||
|
directory (".") and then in @CONFIGDIR@. If the value of the
|
||||||
|
environment variable ends with the directory separator character, then
|
||||||
|
the default directories are searched after the explicitly specified
|
||||||
|
directories. For example, setting
|
||||||
|
.B SANE_CONFIG_DIR
|
||||||
|
to "/tmp/config:" would result in directories "tmp/config", ".", and
|
||||||
|
"@CONFIGDIR@" being searched (in this order).
|
||||||
|
.TP
|
||||||
|
.B SANE_DEBUG_UMAX_PP
|
||||||
|
If the library was compiled with debug support enabled, this
|
||||||
|
environment variable controls the debug level for this backend. E.g.,
|
||||||
|
a value of 128 requests all debug output to be printed. Smaller
|
||||||
|
levels reduce verbosity.
|
||||||
|
|
||||||
|
.PP
|
||||||
|
.RS
|
||||||
|
level debug output
|
||||||
|
.br
|
||||||
|
------- ------------------------------
|
||||||
|
.br
|
||||||
|
0 nothing
|
||||||
|
.br
|
||||||
|
1 errors
|
||||||
|
.br
|
||||||
|
2 warnings & minor errors
|
||||||
|
.br
|
||||||
|
3 additional information
|
||||||
|
.br
|
||||||
|
4 debug information
|
||||||
|
.br
|
||||||
|
5 code flow (not supported yet)
|
||||||
|
.br
|
||||||
|
6 special debug information
|
||||||
|
.RE
|
||||||
|
.PP
|
||||||
|
.TP
|
||||||
|
.B SANE_DEBUG_UMAX_PP_LOW
|
||||||
|
This variable sets the debug level for the SANE interface for the Umax
|
||||||
|
ASIC. Note that enabling this will spam your terminal with some
|
||||||
|
million lines of debug output.
|
||||||
|
|
||||||
|
.PP
|
||||||
|
.RS
|
||||||
|
level debug output
|
||||||
|
.br
|
||||||
|
------- -------------------------------
|
||||||
|
.br
|
||||||
|
0 nothing
|
||||||
|
.br
|
||||||
|
1 errors
|
||||||
|
.br
|
||||||
|
8 command blocks
|
||||||
|
.br
|
||||||
|
16 detailed code flow
|
||||||
|
.br
|
||||||
|
32 dump datafiles
|
||||||
|
.br
|
||||||
|
255 everything
|
||||||
|
.RE
|
||||||
|
.PP
|
||||||
|
|
||||||
|
.PP
|
||||||
|
.SH "SEE ALSO"
|
||||||
|
sane\-net(5), saned(1)
|
||||||
|
|
||||||
|
.TP
|
||||||
|
For latest bug fixes and information see
|
||||||
|
.I http://umax1220p.sourceforge.net/
|
||||||
|
|
||||||
|
.SH AUTHOR
|
||||||
|
Stéphane VOLTZ <svoltz@wanadoo.fr>, man page derived from mustek_pp man page
|
||||||
|
by Jochen Eisinger <jochen.eisinger@gmx.net>
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
.SH BUG REPORTS
|
||||||
|
If something doesn't work, please contact me. But I need some information about
|
||||||
|
your scanner to be able to help you...
|
||||||
|
|
||||||
|
.TP
|
||||||
|
.I SANE version
|
||||||
|
run "scanimage -V" to determine this
|
||||||
|
.TP
|
||||||
|
.I the backend version and your scanner hardware
|
||||||
|
run "SANE_DEBUG_UMAX=255 scanimage -L 2>log" as root. If you don't get any output
|
||||||
|
from the umax_pp backend, make sure a line "umax_pp" is included into
|
||||||
|
your @CONFIGDIR@/dll.conf.
|
||||||
|
If your scanner isn't detected, make sure you've defined the right port address
|
||||||
|
in your umax_pp.conf.
|
||||||
|
.TP
|
||||||
|
.I the name of your scanner/vendor
|
||||||
|
also a worthy information. Please also include the optical resolution and lamp type of your scanner, both can be found in the manual of your scanner.
|
||||||
|
.TP
|
||||||
|
.I any further comments
|
||||||
|
if you have comments about the documentation (what could be done better), or you
|
||||||
|
think I should know something, please include it.
|