kopia lustrzana https://gitlab.com/sane-project/backends
* backend/canon_pp.c backend/canon_pp.h backend/canon_pp.conf:
Added init_mode option to conf file for faster starts. * doc/sane-canon_pp.man : Added description of init_mode option.DEVEL_2_0_BRANCH-1
rodzic
51a3075282
commit
9fef620345
|
@ -128,9 +128,10 @@ static const SANE_Int res600[] = {4, 75, 150, 300, 600};
|
|||
sane_init (SANE_Int *vc, SANE_Auth_Callback cb)
|
||||
{
|
||||
SANE_Status status = SANE_STATUS_GOOD;
|
||||
int i, tmp;
|
||||
int i, tmp;
|
||||
int tmp_im = INITMODE_AUTO;
|
||||
FILE *fp;
|
||||
char line[80];
|
||||
char line[81]; /* plus 1 for a null */
|
||||
char *tmp_wf, *tmp_port;
|
||||
CANONP_Scanner *s_tmp;
|
||||
|
||||
|
@ -176,13 +177,16 @@ sane_init (SANE_Int *vc, SANE_Auth_Callback cb)
|
|||
if (num_devices == 0)
|
||||
status = SANE_STATUS_IO_ERROR;
|
||||
|
||||
/* just to be extra sure, the line will always have an end: */
|
||||
line[sizeof(line)-1] = '\0';
|
||||
|
||||
/*
|
||||
* Read information from config file: pixel weight location and default
|
||||
* port.
|
||||
*/
|
||||
if((fp = sanei_config_open(CANONP_CONFIG_FILE)))
|
||||
{
|
||||
while(sanei_config_read(line, sizeof (line), fp))
|
||||
while(sanei_config_read(line, sizeof (line) - 1, fp))
|
||||
{
|
||||
DBG(100, "sane_init: >%s<\n", line);
|
||||
if(line[0] == '#') /* ignore line comments */
|
||||
|
@ -227,19 +231,16 @@ sane_init (SANE_Int *vc, SANE_Auth_Callback cb)
|
|||
tmp_port))
|
||||
{
|
||||
s_tmp->weights_file = tmp_wf;
|
||||
break;
|
||||
DBG(100, "sane_init: "
|
||||
"Successfully"
|
||||
" parsed "
|
||||
DBG(100, "sane_init: Parsed "
|
||||
"cal.\n");
|
||||
break;
|
||||
}
|
||||
s_tmp = s_tmp->next;
|
||||
}
|
||||
if (s_tmp == NULL)
|
||||
{
|
||||
/* we made it all the way
|
||||
* through the list and didn't
|
||||
* find the port */
|
||||
/* we made it all the way through the
|
||||
* list and didn't find the port */
|
||||
free(tmp_wf);
|
||||
DBG(10, "sane_init: calibrate line is "
|
||||
"for unknown port!\n");
|
||||
|
@ -264,6 +265,57 @@ sane_init (SANE_Int *vc, SANE_Auth_Callback cb)
|
|||
force_nibble = SANE_TRUE;
|
||||
continue;
|
||||
}
|
||||
|
||||
if(strncmp(line,"init_mode ", 10) == 0)
|
||||
{
|
||||
|
||||
/* parse what sort of initialisation mode to
|
||||
* use */
|
||||
if (strncmp(line+10, "FB620P", 6) == 0)
|
||||
tmp_im = INITMODE_20P;
|
||||
else if (strncmp(line+10, "FB630P", 6) == 0)
|
||||
tmp_im = INITMODE_30P;
|
||||
else if (strncmp(line+10, "AUTO", 4) == 0)
|
||||
tmp_im = INITMODE_AUTO;
|
||||
|
||||
/* now work out which port it blongs to */
|
||||
|
||||
tmp_port = strstr(line+10, " ") + 1;
|
||||
|
||||
if (tmp_port == NULL)
|
||||
{
|
||||
/* first_dev should never be null here
|
||||
* because we found at least one
|
||||
* parallel port above */
|
||||
first_dev->init_mode = tmp_im;
|
||||
DBG(100, "sane_init: Parsed init-1.\n");
|
||||
continue;
|
||||
}
|
||||
|
||||
|
||||
s_tmp = first_dev;
|
||||
while (s_tmp != NULL)
|
||||
{
|
||||
if (!strcmp(s_tmp->params.port->name,
|
||||
tmp_port+1))
|
||||
{
|
||||
s_tmp->init_mode = tmp_im;
|
||||
DBG(100, "sane_init: Parsed "
|
||||
"init.\n");
|
||||
break;
|
||||
}
|
||||
s_tmp = s_tmp->next;
|
||||
}
|
||||
if (s_tmp == NULL)
|
||||
{
|
||||
/* we made it all the way through the
|
||||
* list and didn't find the port */
|
||||
DBG(10, "sane_init: init_mode line is "
|
||||
"for unknown port!\n");
|
||||
}
|
||||
|
||||
continue;
|
||||
}
|
||||
DBG(1, "sane_init: Unknown configuration command!");
|
||||
|
||||
}
|
||||
|
@ -293,7 +345,8 @@ sane_init (SANE_Int *vc, SANE_Auth_Callback cb)
|
|||
* us to call ieee1284_close in any of the remaining error
|
||||
* cases in this loop. */
|
||||
#if 0
|
||||
tmp = sanei_canon_pp_detect(s_tmp->params.port, INITMODE_AUTO);
|
||||
tmp = sanei_canon_pp_detect(s_tmp->params.port,
|
||||
s_tmp->init_mode);
|
||||
|
||||
|
||||
if (tmp && (s_tmp->ieee1284_mode != M1284_NIBBLE))
|
||||
|
@ -305,7 +358,7 @@ sane_init (SANE_Int *vc, SANE_Auth_Callback cb)
|
|||
s_tmp->ieee1284_mode = M1284_NIBBLE;
|
||||
sanei_canon_pp_set_ieee1284_mode(s_tmp->ieee1284_mode);
|
||||
tmp = sanei_canon_pp_detect(s_tmp->params.port,
|
||||
INITMODE_AUTO);
|
||||
s_tmp->init_mode);
|
||||
}
|
||||
/* still no go? */
|
||||
if (tmp)
|
||||
|
@ -329,47 +382,40 @@ sane_init (SANE_Int *vc, SANE_Auth_Callback cb)
|
|||
|
||||
DBG(2, "sane_init: >> initialise\n");
|
||||
tmp = sanei_canon_pp_initialise(&(s_tmp->params),
|
||||
INITMODE_AUTO);
|
||||
s_tmp->init_mode);
|
||||
DBG(2, "sane_init: << %d initialise\n", tmp);
|
||||
/* put it back to sleep until we're ready to
|
||||
* open for business again */
|
||||
sanei_canon_pp_sleep_scanner(s_tmp->params.port);
|
||||
/* leave the port open but not claimed - this is regardless
|
||||
* of the return value of initialise */
|
||||
ieee1284_release(s_tmp->params.port);
|
||||
if (tmp && (s_tmp->ieee1284_mode != M1284_NIBBLE))
|
||||
{
|
||||
/* A failure, try again in nibble mode... */
|
||||
DBG(1, "sane_init: Failed on ECP mode, falling "
|
||||
"back to nibble mode\n");
|
||||
|
||||
s_tmp->ieee1284_mode = M1284_NIBBLE;
|
||||
sanei_canon_pp_set_ieee1284_mode(s_tmp->ieee1284_mode);
|
||||
tmp = sanei_canon_pp_initialise(&(s_tmp->params),
|
||||
INITMODE_AUTO);
|
||||
}
|
||||
if (tmp) {
|
||||
DBG(10, "sane_init: Couldn't contact scanner on port "
|
||||
"%s. Maybe it's not a scanner?\n",
|
||||
"%s. Probably no scanner there?\n",
|
||||
s_tmp->params.port->name);
|
||||
ieee1284_release(s_tmp->params.port);
|
||||
ieee1284_close(s_tmp->params.port);
|
||||
s_tmp->scanner_present = SANE_FALSE;
|
||||
continue;
|
||||
}
|
||||
|
||||
/* put it back to sleep until we're ready to
|
||||
* open for business again - this will only work
|
||||
* if we actually have a scanner there! */
|
||||
DBG(100, "sane_init: And back to sleep again\n");
|
||||
sanei_canon_pp_sleep_scanner(s_tmp->params.port);
|
||||
|
||||
/* leave the port open but not claimed - this is regardless
|
||||
* of the return value of initialise */
|
||||
ieee1284_release(s_tmp->params.port);
|
||||
|
||||
/* Finally, we're sure there's a scanner there! Now we
|
||||
* just have to load the weights file...*/
|
||||
|
||||
if (fix_weights_file(s_tmp) != SANE_STATUS_GOOD) {
|
||||
DBG(1, "sane_init: Eeek! fix_weights_file failed for "
|
||||
"scanner on port %s!\n",
|
||||
s_tmp->params.port->name);
|
||||
|
||||
ieee1284_close(s_tmp->params.port);
|
||||
continue;
|
||||
/* non-fatal.. scans will look ugly as sin unless
|
||||
* they calibrate */
|
||||
}
|
||||
|
||||
/* Cocked, locked and ready to rock */
|
||||
|
||||
s_tmp->hw.model = s_tmp->params.name;
|
||||
s_tmp->scanner_present = SANE_TRUE;
|
||||
}
|
||||
|
@ -527,7 +573,7 @@ sane_open (SANE_String_Const name, SANE_Handle *h)
|
|||
/* I put the scanner to sleep before, better wake it back up */
|
||||
|
||||
DBG(2, "sane_open: >> initialise\n");
|
||||
tmp = sanei_canon_pp_initialise(&(cs->params), INITMODE_AUTO);
|
||||
tmp = sanei_canon_pp_initialise(&(cs->params), cs->init_mode);
|
||||
DBG(2, "sane_open: << %d initialise\n", tmp);
|
||||
if (tmp != 0) {
|
||||
DBG(1, "sane_open: initialise returned %d, something is "
|
||||
|
@ -1571,6 +1617,7 @@ static SANE_Status init_device(struct parport *pp)
|
|||
cs->sent_eof = SANE_TRUE;
|
||||
cs->lines_scanned = 0;
|
||||
cs->bytes_sent = 0;
|
||||
cs->init_mode = INITMODE_AUTO;
|
||||
|
||||
DBG(10, "init_device: [configuring options]\n");
|
||||
|
||||
|
@ -1957,7 +2004,10 @@ SANE_Status detect_mode(CANONP_Scanner *cs)
|
|||
* by libieee1284 now, and it's too prone to hitting a ppdev bug
|
||||
*/
|
||||
|
||||
if (/*(cs->ieee1284_mode == M1284_ECP) ||*/
|
||||
/* Disabled check entirely.. check now in initialise when we
|
||||
* actually do a read */
|
||||
#if 0
|
||||
if ((cs->ieee1284_mode == M1284_ECP) ||
|
||||
(cs->ieee1284_mode == M1284_ECPSWE))
|
||||
{
|
||||
DBG(1, "detect_mode: attempting a 0 byte read, if we hang "
|
||||
|
@ -1969,8 +2019,8 @@ SANE_Status detect_mode(CANONP_Scanner *cs)
|
|||
* Not checking on hardware ECP mode should work-around
|
||||
* effectively.
|
||||
*
|
||||
* I have sent email to twaugh about it, should be fixed in 2.4.19
|
||||
* and above.
|
||||
* I have sent email to twaugh about it, should be fixed in
|
||||
* 2.4.19 and above.
|
||||
*/
|
||||
if (ieee1284_ecp_read_data(cs->params.port, 0, NULL, 0) ==
|
||||
E1284_NOTIMPL)
|
||||
|
@ -1981,6 +2031,7 @@ SANE_Status detect_mode(CANONP_Scanner *cs)
|
|||
cs->ieee1284_mode = M1284_NIBBLE;
|
||||
}
|
||||
}
|
||||
#endif
|
||||
|
||||
if (force_nibble == SANE_TRUE) {
|
||||
DBG(10, "detect_mode: Nibble mode force in effect.\n");
|
||||
|
|
|
@ -26,3 +26,11 @@ calibrate ~/.sane/canon_pp-calibration-pp0 parport0
|
|||
|
||||
#force_nibble
|
||||
|
||||
# Set a default initialisation mode for each port. Valid modes are:
|
||||
# AUTO (attempts to automatically detect by trying both methods)
|
||||
# FB620P (10101010 style.. also works for FB320P)
|
||||
# FB630P (11001100 style.. also works for FB330P, N340P, N640P)
|
||||
|
||||
init_mode AUTO parport0
|
||||
# init_mode FB620P parport0
|
||||
# init_mode FB630P parport0
|
||||
|
|
|
@ -111,6 +111,7 @@ struct CANONP_Scanner_Struct
|
|||
scan_parameters scan;
|
||||
|
||||
int ieee1284_mode;
|
||||
int init_mode;
|
||||
|
||||
SANE_Bool scanner_present;
|
||||
|
||||
|
|
|
@ -65,6 +65,7 @@ starting with a hash mark (#) are ignored.
|
|||
The supported options are currently
|
||||
.BR ieee1284 ,
|
||||
.BR calibrate ,
|
||||
.BR init_mode ,
|
||||
and
|
||||
.BR force_nibble
|
||||
|
||||
|
@ -80,10 +81,25 @@ Option
|
|||
.IR cal-file
|
||||
.IR [portname]
|
||||
defines which calibration file to use on a per-port basis. If you only have
|
||||
one scanner, the portname argument may be omitted - but be careful as this
|
||||
one parport, the portname argument may be omitted - but be careful as this
|
||||
will cause problems on multi-scanner systems. You may have as many of these
|
||||
lines as you like, as long as each has a unique port name. The tilde (`~')
|
||||
character is acceptable and will be expaned to the value of the HOME environment.
|
||||
character is acceptable and will be expaned to the value of the HOME
|
||||
environment.
|
||||
|
||||
Option
|
||||
.B init_mode
|
||||
.IR <AUTO|FB620P|FB630P>
|
||||
.IR [portname]
|
||||
defines which initialisation (wake-up) mode to use on a per-port basis.
|
||||
If you only have one parport, the portname argument may be omitted - but
|
||||
be careful as this may cause problems on multi-scanner systems.
|
||||
You may have as many of these lines as you like, as long as each has a unique
|
||||
port name. The valid initialisation modes are FB620P (which strobes 10101010
|
||||
and 01010101 on the data pins), FB630P (which strobes 11001100 and 00110011
|
||||
on the data pins) and AUTO, which will try FB630P mode first then FB620P mode
|
||||
second. The FB620P mode is also used by the FB320P. The FB630P mode is used
|
||||
by the FB330P, N340P, and N640P.
|
||||
|
||||