kopia lustrzana https://gitlab.com/sane-project/backends
				
				
				
			canon_dr backend v57
- complete support for X-10, including hardware cropping (by manuarg) - minor comments and move a bit of code for consistencymerge-requests/43/head
							rodzic
							
								
									81faeb46f2
								
							
						
					
					
						commit
						9c4ac1f07f
					
				| 
						 | 
				
			
			@ -336,6 +336,8 @@
 | 
			
		|||
         - rename all DUPLEX_INTERLACE_* to indicate start and end of line
 | 
			
		||||
      v56 2016-08-23, MAN
 | 
			
		||||
         - initial support for P-150
 | 
			
		||||
      v57 2019-02-24, manuarg
 | 
			
		||||
         - complete support for X-10, including hardware cropping
 | 
			
		||||
 | 
			
		||||
   SANE FLOW DIAGRAM
 | 
			
		||||
 | 
			
		||||
| 
						 | 
				
			
			@ -386,7 +388,7 @@
 | 
			
		|||
#include "canon_dr.h"
 | 
			
		||||
 | 
			
		||||
#define DEBUG 1
 | 
			
		||||
#define BUILD 56
 | 
			
		||||
#define BUILD 57
 | 
			
		||||
 | 
			
		||||
/* values for SANE_DEBUG_CANON_DR env var:
 | 
			
		||||
 - errors           5
 | 
			
		||||
| 
						 | 
				
			
			@ -2956,6 +2958,10 @@ sane_control_option (SANE_Handle handle, SANE_Int option,
 | 
			
		|||
          *val_p = s->side;
 | 
			
		||||
          return SANE_STATUS_GOOD;
 | 
			
		||||
 | 
			
		||||
        case OPT_HW_CROP:
 | 
			
		||||
          *val_p = s->hwcrop;
 | 
			
		||||
          return SANE_STATUS_GOOD;
 | 
			
		||||
 | 
			
		||||
        /* Sensor Group */
 | 
			
		||||
        case OPT_START:
 | 
			
		||||
          ret = read_panel(s,OPT_START);
 | 
			
		||||
| 
						 | 
				
			
			@ -3001,10 +3007,6 @@ sane_control_option (SANE_Handle handle, SANE_Int option,
 | 
			
		|||
          ret = read_sensors(s,OPT_CARD_LOADED);
 | 
			
		||||
          *val_p = s->sensor_card_loaded;
 | 
			
		||||
          return ret;
 | 
			
		||||
 | 
			
		||||
        case OPT_HW_CROP:
 | 
			
		||||
          *val_p = s->hwcrop;
 | 
			
		||||
          return SANE_STATUS_GOOD;
 | 
			
		||||
      }
 | 
			
		||||
  }
 | 
			
		||||
  else if (action == SANE_ACTION_SET_VALUE) {
 | 
			
		||||
| 
						 | 
				
			
			@ -3910,6 +3912,7 @@ send_panel(struct scanner *s)
 | 
			
		|||
/*
 | 
			
		||||
 * Request the size of the scanned image
 | 
			
		||||
 */
 | 
			
		||||
/* we should really be updating s->s and s->i instead */
 | 
			
		||||
static SANE_Status
 | 
			
		||||
get_pixelsize(struct scanner *s)
 | 
			
		||||
{
 | 
			
		||||
| 
						 | 
				
			
			@ -4330,6 +4333,7 @@ sane_start (SANE_Handle handle)
 | 
			
		|||
      DBG (5, "sane_start: ERROR: cannot send panel\n");
 | 
			
		||||
    }
 | 
			
		||||
 | 
			
		||||
    /* we should really be updating s->s and s->i instead */
 | 
			
		||||
    if(s->hwcrop){
 | 
			
		||||
      s->u.br_x = s->max_x;
 | 
			
		||||
      s->u.tl_x = 0;
 | 
			
		||||
| 
						 | 
				
			
			
 | 
			
		|||
| 
						 | 
				
			
			@ -11,9 +11,9 @@
 | 
			
		|||
 | 
			
		||||
:backend "canon_dr"              ; name of backend
 | 
			
		||||
:url "http://www.thebility.com/canon/"
 | 
			
		||||
:version "51"                    ; version of backend
 | 
			
		||||
:version "57"                    ; version of backend
 | 
			
		||||
:manpage "sane-canon_dr"         ; name of manpage (if it exists)
 | 
			
		||||
:comment "Backend updated for SANE release 1.0.25, see sane-canon_dr manpage"
 | 
			
		||||
:comment "Backend updated for SANE release 1.0.28, see sane-canon_dr manpage"
 | 
			
		||||
:devicetype :scanner             ; start of a list of devices....
 | 
			
		||||
                                 ; other types:  :stillcam, :vidcam,
 | 
			
		||||
                                 ;               :meta, :api
 | 
			
		||||
| 
						 | 
				
			
			
 | 
			
		|||
| 
						 | 
				
			
			@ -10,7 +10,7 @@ The
 | 
			
		|||
library implements a SANE (Scanner Access Now Easy) backend which
 | 
			
		||||
provides access to some Canon DR-series scanners.
 | 
			
		||||
 | 
			
		||||
This document describes backend version 51, which shipped with SANE 1.0.25.
 | 
			
		||||
This document describes backend version 57, which shipped with SANE 1.0.28.
 | 
			
		||||
 | 
			
		||||
.SH SUPPORTED HARDWARE
 | 
			
		||||
This version has only been tested with a few scanner models. Please see
 | 
			
		||||
| 
						 | 
				
			
			
 | 
			
		|||
		Ładowanie…
	