kopia lustrzana https://gitlab.com/sane-project/backends
- updated sane-umax_pp man page
rodzic
2c71e5e59b
commit
96f129a8cb
|
@ -1,3 +1,7 @@
|
|||
2003-09-16 Stéphane Voltz <svoltz@wanadoo.fr>
|
||||
|
||||
* doc/sane-umax_pp_low.man: updated man page
|
||||
|
||||
2003-09-15 Simon Munton <simon@munton.demon.co.uk>
|
||||
|
||||
* doc/sane-pie.man doc/descriptions/pie.desc: Updated status of ScanAce
|
||||
|
|
|
@ -1,49 +1,49 @@
|
|||
.TH sane-umax_pp 5 "15 February 2002" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
|
||||
.IX sane-umax_pp
|
||||
.SH NAME
|
||||
sane-umax_pp \- SANE backend for Umax parallel port flatbed scanners
|
||||
.SH DESCRIPTION
|
||||
.\" .IX sane-umax_pp
|
||||
.TH "sane-umax_pp" "5" "16 September 2003" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy"
|
||||
.SH "NAME"
|
||||
sane\-umax_pp \- SANE backend for Umax Astra parallel port flatbed scanners
|
||||
.SH "DESCRIPTION"
|
||||
The
|
||||
.B sane-umax_pp
|
||||
.B sane\-umax_pp
|
||||
library implements a SANE (Scanner Access Now Easy) backend that
|
||||
provides access to Umax parallel port flatbed scanners. The
|
||||
following scanners work with this backend:
|
||||
.PP
|
||||
.PP
|
||||
.RS
|
||||
Model:
|
||||
.br
|
||||
--------------------
|
||||
.br
|
||||
.br
|
||||
\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-
|
||||
.br
|
||||
Astra 1220P
|
||||
.br
|
||||
.br
|
||||
HP3200C
|
||||
.br
|
||||
.br
|
||||
Astra 1600P
|
||||
.br
|
||||
.br
|
||||
Astra 2000P
|
||||
.br
|
||||
.br
|
||||
.RE
|
||||
.PP
|
||||
.PP
|
||||
This backend handles 75x75, 150x150, 300x300, 600x600 and 600x1200 dpi scan
|
||||
resolutions, in color and gray levels. There is a software lineart mode.
|
||||
.PP
|
||||
.PP
|
||||
These scanners share the same ASIC. Only parts such as CCD and ADC change from
|
||||
one to another. They even all reports being UMAX Astra 1220P via IEEE1284.
|
||||
There isn't software way to recognize them properly. Under windows, model is
|
||||
set by the driver installed, regardless of the hardware.
|
||||
.PP
|
||||
.TP
|
||||
.PP
|
||||
.TP
|
||||
.B EPP MODE ONLY
|
||||
The current version of the backend use only EPP mode to communicate with the
|
||||
scanner. PS/2 and SPP mode aren't implemented. It is recommended that you set
|
||||
your parallel port to EPP in BIOS with the current version of this backend.
|
||||
ECPEPP will only work if you use a 2.4 kernel with ppdev character device support.
|
||||
.PP
|
||||
.PP
|
||||
This backend does support parport sharing only
|
||||
.I
|
||||
if you have a kernel with ppdev support.
|
||||
.I
|
||||
.PP
|
||||
.PP
|
||||
Note that if you don't use the ppdev character device, the backend
|
||||
needs to run as root. To allow user access to the scanner
|
||||
run the backend through the network interface (See saned(1) and sane\-net(5)).
|
||||
|
@ -54,107 +54,111 @@ access to IO ports, which lessen risks when being root.
|
|||
|
||||
.SH "DEVICE NAMES"
|
||||
This backend expects device names of the form:
|
||||
.PP
|
||||
.PP
|
||||
.RS
|
||||
.I port value
|
||||
.RE
|
||||
.PP
|
||||
.PP
|
||||
Where
|
||||
.B value
|
||||
\fBvalue\fR
|
||||
is the base address, or the ppdev device name of the port your scanner is attached to.
|
||||
Known ports are
|
||||
.B 0x378
|
||||
(lp1)
|
||||
.B 0x278
|
||||
(lp2) and
|
||||
.B 0x3BC
|
||||
(lp0). Note that if you are using a Kernel 2.2.x or better , the first
|
||||
parallel port is named lp0 regardless of the base address. However,
|
||||
this backend requires the base address of your port. If you are not sure which
|
||||
port your scanner is connected to, have a look at your /etc/modules.conf.
|
||||
.PP
|
||||
Known ports are \fB0x378\fR, \fB0x278\fR and \fB0x3BC\fR . Or the name of the
|
||||
parallel port character device user interface, such as /dev/parport0 for the linux ppdev,
|
||||
or /dev/ppi0 for FreeBSD ppi.
|
||||
.br
|
||||
Under linux, if you are not sure which
|
||||
port your scanner is connected to, may have a look at your /etc/modules.conf. Also typing
|
||||
dmesg|grep parport in a command shell should show you a line like:
|
||||
.br
|
||||
parport0: PC\-style at 0x378 (0x778), irq 7, dma 3 [PCSPP,TRISTATE,COMPAT,ECP,DMA]
|
||||
.br
|
||||
telling you about port address and mode.
|
||||
.PP
|
||||
If you are using the linux ppdev character device, you will have to specify
|
||||
the device name, which is /dev/parport0 for the first parallel port. Check
|
||||
the permissions on /dev/paraport0, many linux distributions restrict them
|
||||
for root only access. Get sure they are like:
|
||||
.br
|
||||
crw-rw-rw- 1 root root 99, 0 mai 20 2002 /dev/parport0
|
||||
.br
|
||||
crw-rw-rw- 1 root root 99, 1 mai 20 2002 /dev/parport1
|
||||
.br
|
||||
crw-rw-rw- 1 root root 99, 2 mai 20 2002 /dev/parport2
|
||||
.br
|
||||
crw-rw-rw- 1 root root 99, 3 mai 20 2002 /dev/parport3
|
||||
.br
|
||||
|
||||
.br
|
||||
crw\-rw\-rw\- 1 root root 99, 0 mai 20 2002 /dev/parport0
|
||||
.br
|
||||
crw\-rw\-rw\- 1 root root 99, 1 mai 20 2002 /dev/parport1
|
||||
.br
|
||||
crw\-rw\-rw\- 1 root root 99, 2 mai 20 2002 /dev/parport2
|
||||
.br
|
||||
crw\-rw\-rw\- 1 root root 99, 3 mai 20 2002 /dev/parport3
|
||||
.br
|
||||
.br
|
||||
The same apply with the /dev/ppi0 character device under FreeBSD.
|
||||
.br
|
||||
|
||||
You can rename any device using the
|
||||
.PP
|
||||
.PP
|
||||
.RS
|
||||
.I name devname
|
||||
.br
|
||||
.br
|
||||
.I model model
|
||||
.br
|
||||
.br
|
||||
.I vendor vendor
|
||||
.RE
|
||||
.PP
|
||||
.PP
|
||||
options. These options apply to the last port option.
|
||||
|
||||
.SH CONFIGURATION
|
||||
.SH "CONFIGURATION"
|
||||
Please make sure to edit umax_pp.conf
|
||||
.B before
|
||||
you use the backend.
|
||||
.PP
|
||||
.PP
|
||||
The contents of the
|
||||
.B umax_pp.conf
|
||||
file is a list of options and device names that correspond to Umax
|
||||
scanners. Empty lines and lines starting with a hash mark (#) are
|
||||
ignored.
|
||||
.PP
|
||||
.PP
|
||||
The height options supported are
|
||||
.BR red-brightness ,
|
||||
.BR green-brightness ,
|
||||
.BR blue-brightness ,
|
||||
.BR red-contrast ,
|
||||
.BR green-contrast ,
|
||||
.BR blue-contrast ,
|
||||
.BR red\-brightness ,
|
||||
.BR green\-brightness ,
|
||||
.BR blue\-brightness ,
|
||||
.BR red\-contrast ,
|
||||
.BR green\-contrast ,
|
||||
.BR blue\-contrast ,
|
||||
.BR astra ,
|
||||
and
|
||||
.BR buffer .
|
||||
|
||||
Options
|
||||
.B red-brightness
|
||||
.B red\-brightness
|
||||
,
|
||||
.B green-brightness
|
||||
.B green\-brightness
|
||||
and
|
||||
.B blue-brightness
|
||||
.B blue\-brightness
|
||||
allow you to adjust the sensitivy of your scanner for the given color. Values
|
||||
range from 0 (lowest brightness) to 15 (highest). The "Brightness" option isn't
|
||||
checked in the frontend, the backend does automatic brightness calibration.
|
||||
range from 0 (lowest brightness) to 15 (highest). If the advanced option "Brightness" isn't
|
||||
checked in the frontend, the backend does automatic brightness calibration, and do not use
|
||||
user provided values.
|
||||
|
||||
.PP
|
||||
.PP
|
||||
|
||||
Options
|
||||
.B red-contrast
|
||||
.B red\-contrast
|
||||
,
|
||||
.B green-contrast
|
||||
.B green\-contrast
|
||||
and
|
||||
.B blue-contrast
|
||||
.B blue\-contrast
|
||||
allow you to adjust the contrast of your scanner for the given color. Values
|
||||
range from 0 (lowest contrast) to 15 (highest).
|
||||
.PP
|
||||
.PP
|
||||
|
||||
Option
|
||||
.B astra
|
||||
allows you to change the model of your scanner. Current auto detection is based
|
||||
on side effects on scanning when using 1220P command set on other models, so
|
||||
it may fail on unkown hardware combination. Valid values are 1220, 1600
|
||||
and 2000. It is usefull only autodetection fails to detect properly your scanner
|
||||
and 2000. It is usefull only when autodetection fails to detect properly your scanner
|
||||
model. If your scanner work properly but is reported wrongly, let it be that way.
|
||||
The only valid case to change the model is when your scanner produces 'black' or
|
||||
'inverted' scans. In this case you can put the model. Be aware that it will
|
||||
prevent autodetection.
|
||||
.PP
|
||||
.PP
|
||||
|
||||
Option
|
||||
.B buffer
|
||||
|
@ -162,31 +166,31 @@ allows you to change the size of the scan buffer. The size must be specified in
|
|||
bytes. The default value is 2 megabytes. Decreasing this value will improve the
|
||||
progress status reporting in the frontend, but will stall the scan more often.
|
||||
|
||||
.PP
|
||||
.PP
|
||||
|
||||
|
||||
|
||||
.SH FILES
|
||||
.TP
|
||||
.SH "FILES"
|
||||
.TP
|
||||
.I @CONFIGDIR@/umax_pp.conf
|
||||
The backend configuration file (see also description of
|
||||
.B SANE_CONFIG_DIR
|
||||
below).
|
||||
.TP
|
||||
.TP
|
||||
.I @LIBDIR@/libsane\-umax_pp.a
|
||||
The static library implementing this backend.
|
||||
.TP
|
||||
.TP
|
||||
.I @LIBDIR@/libsane\-umax_pp.so
|
||||
The shared library implementing this backend (present on systems that
|
||||
support dynamic loading).
|
||||
|
||||
.SH ENVIRONMENT
|
||||
.TP
|
||||
.SH "ENVIRONMENT"
|
||||
.TP
|
||||
.B SANE_CONFIG_DIR
|
||||
This environment variable specifies the list of directories that may
|
||||
contain the configuration file. Under UNIX, the directories are
|
||||
separated by a colon (`:'), under OS/2, they are separated by a
|
||||
semi-colon (`;'). If this variable is not set, the configuration file
|
||||
semi\-colon (`;'). If this variable is not set, the configuration file
|
||||
is searched in two default directories: first, the current working
|
||||
directory (".") and then in @CONFIGDIR@. If the value of the
|
||||
environment variable ends with the directory separator character, then
|
||||
|
@ -195,92 +199,93 @@ directories. For example, setting
|
|||
.B SANE_CONFIG_DIR
|
||||
to "/tmp/config:" would result in directories "tmp/config", ".", and
|
||||
"@CONFIGDIR@" being searched (in this order).
|
||||
.TP
|
||||
.TP
|
||||
.B SANE_DEBUG_UMAX_PP
|
||||
If the library was compiled with debug support enabled, this
|
||||
environment variable controls the debug level for this backend. E.g.,
|
||||
a value of 128 requests all debug output to be printed. Smaller
|
||||
levels reduce verbosity.
|
||||
|
||||
.PP
|
||||
.PP
|
||||
.RS
|
||||
level debug output
|
||||
.br
|
||||
------- ------------------------------
|
||||
.br
|
||||
.br
|
||||
\-\-\-\-\-\-\- \-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-
|
||||
.br
|
||||
0 nothing
|
||||
.br
|
||||
.br
|
||||
1 errors
|
||||
.br
|
||||
.br
|
||||
2 warnings & minor errors
|
||||
.br
|
||||
.br
|
||||
3 additional information
|
||||
.br
|
||||
.br
|
||||
4 debug information
|
||||
.br
|
||||
.br
|
||||
5 code flow (not supported yet)
|
||||
.br
|
||||
.br
|
||||
6 special debug information
|
||||
.RE
|
||||
.PP
|
||||
.TP
|
||||
.PP
|
||||
.TP
|
||||
.B SANE_DEBUG_UMAX_PP_LOW
|
||||
This variable sets the debug level for the SANE interface for the Umax
|
||||
ASIC. Note that enabling this will spam your terminal with some
|
||||
million lines of debug output.
|
||||
|
||||
.PP
|
||||
.PP
|
||||
.RS
|
||||
level debug output
|
||||
.br
|
||||
------- -------------------------------
|
||||
.br
|
||||
.br
|
||||
\-\-\-\-\-\-\- \-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-\-
|
||||
.br
|
||||
0 nothing
|
||||
.br
|
||||
.br
|
||||
1 errors
|
||||
.br
|
||||
.br
|
||||
8 command blocks
|
||||
.br
|
||||
.br
|
||||
16 detailed code flow
|
||||
.br
|
||||
.br
|
||||
32 dump datafiles
|
||||
.br
|
||||
.br
|
||||
255 everything
|
||||
.RE
|
||||
.PP
|
||||
.PP
|
||||
|
||||
.PP
|
||||
.PP
|
||||
.SH "SEE ALSO"
|
||||
sane(7), sane\-net(5), saned(1)
|
||||
|
||||
.TP
|
||||
.TP
|
||||
For latest bug fixes and information see
|
||||
.I http://umax1220p.sourceforge.net/
|
||||
|
||||
.SH AUTHOR
|
||||
.SH "AUTHOR"
|
||||
Stéphane VOLTZ <svoltz@wanadoo.fr>, man page derived from mustek_pp man page
|
||||
by Jochen Eisinger <jochen.eisinger@gmx.net>
|
||||
|
||||
|
||||
|
||||
.SH BUG REPORTS
|
||||
.SH "BUG REPORTS"
|
||||
If something doesn't work, please contact me. But I need some information about
|
||||
your scanner to be able to help you...
|
||||
|
||||
.TP
|
||||
.TP
|
||||
.I SANE version
|
||||
run "scanimage -V" to determine this
|
||||
.TP
|
||||
run "scanimage \-V" to determine this
|
||||
.TP
|
||||
.I the backend version and your scanner hardware
|
||||
run "SANE_DEBUG_UMAX=255 scanimage -L 2>log" as root. If you don't get any output
|
||||
run "SANE_DEBUG_UMAX=255 scanimage \-L 2>log" as root. If you don't get any output
|
||||
from the umax_pp backend, make sure a line "umax_pp" is included into
|
||||
your @CONFIGDIR@/dll.conf.
|
||||
If your scanner isn't detected, make sure you've defined the right port address
|
||||
If your scanner isn't detected, make sure you've defined the right port address, or the
|
||||
correct device
|
||||
in your umax_pp.conf.
|
||||
.TP
|
||||
.TP
|
||||
.I the name of your scanner/vendor
|
||||
also a worthy information. Please also include the optical resolution and lamp type of your scanner, both can be found in the manual of your scanner.
|
||||
.TP
|
||||
.TP
|
||||
.I any further comments
|
||||
if you have comments about the documentation (what could be done better), or you
|
||||
think I should know something, please include it.
|
||||
|
|
Ładowanie…
Reference in New Issue