kopia lustrzana https://gitlab.com/sane-project/backends
genesys: Fix incorrect scan exposure setup on gl841
When sensor exposure values are significantly different from each other the total scan exposure will be too low leading to the device becoming confused and significantlyrelease-1.1.x
rodzic
7b25c36c15
commit
72d0c39656
|
@ -899,9 +899,9 @@ static int gl841_exposure_time(Genesys_Device *dev, const Genesys_Sensor& sensor
|
|||
int led_exposure = 0;
|
||||
if (dev->model->is_cis) {
|
||||
unsigned dummy = dev->reg.find_reg(0x19).value;
|
||||
unsigned min_sensor_exposure = std::min({sensor.exposure.red, sensor.exposure.green,
|
||||
unsigned max_sensor_exposure = std::max({sensor.exposure.red, sensor.exposure.green,
|
||||
sensor.exposure.blue});
|
||||
led_exposure = dummy + min_sensor_exposure;
|
||||
led_exposure = dummy + max_sensor_exposure;
|
||||
}
|
||||
return sanei_genesys_exposure_time2(dev, profile, slope_dpi,
|
||||
start + used_pixels,/*+tgtime? currently done in sanei_genesys_exposure_time2 with tgtime = 32 pixel*/
|
||||
|
|