avision.c: Add "skip-adf" option

The code which tries aggressively to reset/initialize HP 82xx/83xx
Automatic Document Feeders doesn't work well if there's no ADF attached,
because the scanner reports a non-zero ADF model type in this case.
The retry code makes several attempts to initialize the ADF, and then
bails out with an "Operation not supported" error.

Add a new "option skip-adf" which will cause the backend to believe
the "ADF not present" status if that's what the scanner reports.

Fixes #313751
merge-requests/1/head
Dave Platt 2016-12-15 22:29:16 -08:00
rodzic f58ce8f920
commit 6585b6f60d
2 zmienionych plików z 22 dodań i 2 usunięć

Wyświetl plik

@ -1277,6 +1277,9 @@ static SANE_Bool force_calibration = SANE_FALSE;
static SANE_Bool force_a4 = SANE_FALSE;
static SANE_Bool force_a3 = SANE_FALSE;
/* trust ADF-presence flag, even if ADF model is nonzero */
static SANE_Bool skip_adf = SANE_FALSE;
/* hardware resolutions to interpolate from */
static const int hw_res_list_c5[] =
{
@ -3218,11 +3221,13 @@ get_accessories_info (Avision_Scanner* s)
{
dev->inquiry_duplex = 1;
dev->inquiry_duplex_interlaced = 0;
} else if (result[0] == 0 && result[2] != 0) {
} else if (result[0] == 0 && result[2] != 0 && !skip_adf) {
/* Sometimes the scanner will report that there is no ADF attached, yet
* an ADF model number will still be reported. This happens on the
* HP8200 series and possibly others. In this case we need to reset the
* the adf and try reading it again.
* the adf and try reading it again. Skip this if the configuration says
* to do so, so that we don't fail out the scanner as being broken and
* unsupported if there isn't actually an ADF present.
*/
DBG (3, "get_accessories_info: Found ADF model number but the ADF-present flag is not set. Trying to recover...\n");
status = adf_reset (s);
@ -7627,6 +7632,11 @@ sane_reload_devices (void)
linenumber);
force_a3 = SANE_TRUE;
}
else if (strcmp (word, "skip-adf") == 0) {
DBG (3, "sane_reload_devices: config file line %d: enabling skip-adf\n",
linenumber);
skip_adf = SANE_TRUE;
}
else if (strcmp (word, "static-red-calib") == 0) {
DBG (3, "sane_reload_devices: config file line %d: static red calibration\n",
linenumber);

Wyświetl plik

@ -36,6 +36,7 @@ a hash mark (#) are ignored. A sample configuration file is shown below:
\
option force\-a4
option force\-a3
option skip\-adf
option disable\-gamma\-table
option disable\-calibration
\
@ -61,6 +62,15 @@ known to return bogus data are marked in the backend
so if you need this option please report this to the
backend maintainer. USE WITH CARE!
.TP
skip\-adf:
Forces the backend to ignore an inconsistent ADF
status returned by the scanner (ADF not present, but
ADF model number non-zero). Without this option, the
backend will make several attempts to reset the ADF
and retry the query in this situation, and will fail
with a "not supported" error if the ADF still doesn't
respond.
.TP
disable\-gamma\-table:
Disables the usage of the scanner's gamma-table. You
might try this if your scans hang or only produces