kopia lustrzana https://gitlab.com/sane-project/backends
Initial revision
rodzic
885e39f30e
commit
64a6bf656c
|
@ -0,0 +1,27 @@
|
|||
:backend "microtek2" ; name of backend
|
||||
:version "0.6" ; version of backend
|
||||
:status :alpha ; :alpha, :beta, :stable, :new
|
||||
:manpage "sane-microtek2" ; name of manpage (if it exists)
|
||||
|
||||
:devicetype :scanner ; start of a list of devices....
|
||||
|
||||
:mfg "Microtek" ; name a manufacturer
|
||||
:url "http://www.microtek.com/"
|
||||
:model "parallel models unsupported"
|
||||
:model "ScanMaker V300"
|
||||
:model "ScanMaker V310"
|
||||
:model "ScanMaker V600"
|
||||
:model "ScanMaker E3plus" ; name models for above-specified mfg.
|
||||
:model "ScanMaker X6"
|
||||
:model "ScanMaker X6EL"
|
||||
:model "ScanMaker 330"
|
||||
:model "ScanMaker 630"
|
||||
:model "ScanMaker 636"
|
||||
:model "ScanMaker 9600XL"
|
||||
:comment "only flatbed mode ?"
|
||||
:model "Phantom 636"
|
||||
|
||||
:mfg "Vobis"
|
||||
:url "http://www.vobis.de/"
|
||||
:model "HighScan" ; name models for above-specified mfg.
|
||||
:comment "only E3plus based models"
|
Plik diff jest za duży
Load Diff
|
@ -0,0 +1,176 @@
|
|||
.TH sane-microtek2 5 "06 Nov 1998"
|
||||
.IX sane-microtek2
|
||||
.SH NAME
|
||||
sane-microtek2 - SANE backend for Microtek scanners with SCSI-2 command set
|
||||
.SH DESCRIPTION
|
||||
The
|
||||
.B sane-microtek2
|
||||
library implements a SANE (Scanner Access Now Easy) backend that
|
||||
provides access to some Microtek scanners with a SCSI-2 command set.
|
||||
This backend should be considered alpha.
|
||||
.PP
|
||||
There exists a different backend for Microtek scanners with SCSI-1
|
||||
command set. Refer to sane-microtek(5) for details.
|
||||
.PP
|
||||
At present, the following
|
||||
scanners are known positively to work with this backend:
|
||||
.PP
|
||||
.RS
|
||||
Vendor Product id: Remark:
|
||||
.br
|
||||
-------- -------------- -----------
|
||||
.br
|
||||
Microtek E3plus all modes ok
|
||||
.br
|
||||
Microtek X6 all modes ok
|
||||
.br
|
||||
Microtek ScanMaker 330 all modes ok
|
||||
.br
|
||||
Microtek ScanMaker 630 all modes ok
|
||||
.br
|
||||
Microtek ScanMaker 636 all modes ok
|
||||
.br
|
||||
Microtek Phantom 636 all modes ok
|
||||
.br
|
||||
Vobis HighScan all modes ok
|
||||
.RE
|
||||
.PP
|
||||
If you own a Microtek scanner with SCSI-2 interface other than the ones
|
||||
listed above, it may or may not work with SANE!
|
||||
|
||||
.SH "FRONTEND OPTIONS"
|
||||
This backend dynamically enables the options for the frontend,
|
||||
that are supported by the scanner in dependence of the scanning-mode
|
||||
and other options. Not supported options are disabled.
|
||||
.PP
|
||||
The following options are supported by the Microtek2-driver:
|
||||
.PP
|
||||
Color, grayscale, halftone and lineart scans.
|
||||
.PP
|
||||
Highlight, midtone, shadow, contrast, brightness, exposure time control,
|
||||
gamma correction, threshold (dependent of the scan mode)
|
||||
.PP
|
||||
Transparency media adapter, automatic document feeder
|
||||
|
||||
.SH "DEVICE NAMES"
|
||||
This backend expects device names of the form:
|
||||
.PP
|
||||
.RS
|
||||
.IR special
|
||||
.RE
|
||||
.PP
|
||||
Where
|
||||
.I special
|
||||
is the UNIX path-name for the special device that corresponds to the
|
||||
scanner. The special device name must be a generic SCSI device or a
|
||||
symlink to such a device. Under Linux, such a device name could be
|
||||
.IR /dev/sga
|
||||
or
|
||||
.IR /dev/sge ,
|
||||
for example.
|
||||
.SH CONFIGURATION
|
||||
The configuration file for this backend resides in
|
||||
.IR @CONFIGDIR@/microtek2.conf .
|
||||
Its contents is a list of device names that correspond to Microtek
|
||||
scanners with SCSI-2 interface. Empty lines and lines starting with
|
||||
a hash mark (#) are ignored.
|
||||
.PP
|
||||
The configuration file may also contain options. Currently two options are
|
||||
supported:
|
||||
.PP
|
||||
.RS
|
||||
option dump <n>
|
||||
.br
|
||||
option strip-height <n>
|
||||
.RE
|
||||
.PP
|
||||
If
|
||||
.I option dump <n>
|
||||
is enabled additional informations about the SCSI
|
||||
commands that are sent to the scanner are printed to stderr. This option
|
||||
is primarily useful for debugging purpose.
|
||||
.PP
|
||||
If n=1 the contents of the command blocks
|
||||
and the results for the INQUIRY and READ SCANNER ATTRIBUTES command are
|
||||
printed to stderr.
|
||||
.PP
|
||||
If n=2 the contents of the command blocks for all other SCSI commands are
|
||||
printed to stderr, too. If n=3 the contents of the gamma table is
|
||||
printed, too. If n=4 all scan data is additionally printed to stderr.
|
||||
.PP
|
||||
The default is n=1.
|
||||
.PP
|
||||
The
|
||||
.I option strip-height <n>
|
||||
, where <n> is a floating point number, limits the amount of data that is
|
||||
read from the scanner with one read command.
|
||||
The unit is inch and <n> defaults to 1.0,
|
||||
if this option is not set in the configuration file. If less than <n> inch
|
||||
of data fit into the SCSI buffer, then the smaller value is used and this
|
||||
option has no effect.
|
||||
.PP
|
||||
If your system has a big SCSI buffer and you want to make use of the whole
|
||||
buffer, increase the value for <n>. For example, if <n> is set to 14.0,
|
||||
no restrictions apply for scanners with a letter, legal or A4 sized
|
||||
scan area.
|
||||
.PP
|
||||
At present the options apply to all devices in the configuration file and
|
||||
cannnot be set on a per device basis.
|
||||
.PP
|
||||
A sample configuration file is shown below:
|
||||
.PP
|
||||
.RS
|
||||
option dump 1
|
||||
.br
|
||||
option strip-height 1.0
|
||||
.br
|
||||
/dev/scanner
|
||||
.br
|
||||
# this is a comment
|
||||
.br
|
||||
/dev/sge
|
||||
.RE
|
||||
|
||||
This backend also supports the new configuration file format which makes
|
||||
it easier to detect scanners under Linux. If you have only one scanner it
|
||||
would be best to use the configuration file for this backend, that
|
||||
is distributed with SANE. This file is shown below:
|
||||
.PP
|
||||
.RS
|
||||
option dump 1
|
||||
.br
|
||||
option strip-height 14.0
|
||||
.br
|
||||
scsi * * Scanner
|
||||
.RE
|
||||
|
||||
In this case all SCSI-Scanners should be detected automatically.
|
||||
|
||||
.SH FILES
|
||||
.TP
|
||||
.I @CONFIGDIR@/microtek2.conf
|
||||
The backend configuration file.
|
||||
.TP
|
||||
.I @LIBDIR@/libsane-microtek2.a
|
||||
The static library implementing this backend.
|
||||
.TP
|
||||
.I @LIBDIR@/libsane-microtek2.so
|
||||
The shared library implementing this backend (present on systems that
|
||||
support dynamic loading).
|
||||
.SH ENVIRONMENT
|
||||
.TP
|
||||
.B SANE_DEBUG_MICROTEK2
|
||||
If the library was compiled with debug support enabled, this
|
||||
environment variable controls the debug level for this backend. E.g.,
|
||||
a value of 128 requests all debug output to be printed. Smaller
|
||||
levels reduce verbosity. To see error messages on stderr set
|
||||
SANE_DEBUG_MICROTEK2 to 1 (Remark: The whole debugging levels should
|
||||
be better revised).
|
||||
.br
|
||||
E.g. just say:
|
||||
.br
|
||||
export SANE_DEBUG_MICROTEK2=128
|
||||
.SH "SEE ALSO"
|
||||
sane-scsi(5)
|
||||
.SH AUTHOR
|
||||
Bernd Schroeder
|
Ładowanie…