kopia lustrzana https://gitlab.com/sane-project/backends
initialize clear and need claibration options
rodzic
03ac144ac8
commit
5d1ebac8e3
|
@ -754,12 +754,29 @@ init_options (GT68xx_Scanner * s)
|
|||
* for now */
|
||||
if (s->dev->model->flags & GT68XX_FLAG_HAS_CALIBRATE)
|
||||
{
|
||||
/* sensor/button group */
|
||||
/* sensor group */
|
||||
s->opt[OPT_SENSOR_GROUP].name = SANE_NAME_SENSORS;
|
||||
s->opt[OPT_SENSOR_GROUP].title = SANE_TITLE_SENSORS;
|
||||
s->opt[OPT_SENSOR_GROUP].desc = SANE_DESC_SENSORS;
|
||||
s->opt[OPT_SENSOR_GROUP].type = SANE_TYPE_GROUP;
|
||||
s->opt[OPT_SENSOR_GROUP].constraint_type = SANE_CONSTRAINT_NONE;
|
||||
|
||||
/* calibration needed */
|
||||
s->opt[OPT_NEED_CALIBRATION_SW].name = "need-calibration";
|
||||
s->opt[OPT_NEED_CALIBRATION_SW].title = SANE_I18N ("Need calibration");
|
||||
s->opt[OPT_NEED_CALIBRATION_SW].desc = SANE_I18N ("The scanner needs calibration for the current settings");
|
||||
s->opt[OPT_NEED_CALIBRATION_SW].type = SANE_TYPE_BOOL;
|
||||
s->opt[OPT_NEED_CALIBRATION_SW].unit = SANE_UNIT_NONE;
|
||||
s->opt[OPT_NEED_CALIBRATION_SW].cap =
|
||||
SANE_CAP_SOFT_DETECT | SANE_CAP_HARD_SELECT | SANE_CAP_ADVANCED;
|
||||
s->val[OPT_NEED_CALIBRATION_SW].b = 0;
|
||||
|
||||
/* button group */
|
||||
s->opt[OPT_BUTTON_GROUP].name = "Buttons";
|
||||
s->opt[OPT_BUTTON_GROUP].title = SANE_I18N ("Buttons");
|
||||
s->opt[OPT_BUTTON_GROUP].desc = SANE_I18N ("Buttons");
|
||||
s->opt[OPT_BUTTON_GROUP].type = SANE_TYPE_GROUP;
|
||||
s->opt[OPT_BUTTON_GROUP].constraint_type = SANE_CONSTRAINT_NONE;
|
||||
|
||||
/* calibrate button */
|
||||
s->opt[OPT_CALIBRATE].name = "calibrate";
|
||||
|
@ -772,6 +789,17 @@ init_options (GT68xx_Scanner * s)
|
|||
SANE_CAP_SOFT_DETECT | SANE_CAP_SOFT_SELECT | SANE_CAP_ADVANCED |
|
||||
SANE_CAP_AUTOMATIC;
|
||||
s->val[OPT_CALIBRATE].b = 0;
|
||||
|
||||
/* clear calibration cache button */
|
||||
s->opt[OPT_CLEAR_CALIBRATION].name = "clear";
|
||||
s->opt[OPT_CLEAR_CALIBRATION].title = SANE_I18N ("Clear calibration");
|
||||
s->opt[OPT_CLEAR_CALIBRATION].desc = SANE_I18N ("Clear calibration cache");
|
||||
s->opt[OPT_CLEAR_CALIBRATION].type = SANE_TYPE_BUTTON;
|
||||
s->opt[OPT_CLEAR_CALIBRATION].unit = SANE_UNIT_NONE;
|
||||
s->opt[OPT_CLEAR_CALIBRATION].cap =
|
||||
SANE_CAP_SOFT_DETECT | SANE_CAP_SOFT_SELECT | SANE_CAP_ADVANCED |
|
||||
SANE_CAP_AUTOMATIC;
|
||||
s->val[OPT_CLEAR_CALIBRATION].b = 0;
|
||||
}
|
||||
|
||||
|
||||
|
@ -1773,7 +1801,7 @@ sane_control_option (SANE_Handle handle, SANE_Int option,
|
|||
break;
|
||||
|
||||
case OPT_NEED_CALIBRATION_SW:
|
||||
*(SANE_Bool *) val = s->calibrated;
|
||||
*(SANE_Bool *) val = !s->calibrated;
|
||||
break;
|
||||
|
||||
default:
|
||||
|
|
Ładowanie…
Reference in New Issue