2004-10-16 Mattias Ellert <mattias.ellert@tsl.uu.se>
|
||||
|
||||
* ltmain.sh: backport -framework support from libtool 2.0
|
||||
* README.darwin: sane-find-scanner now works for SCSI, so removed
|
||||
statement that said it didn't. More libusb info, and link to libusb
|
||||
patch
|
||||
|
||||
2004-10-16 Henning Meier-Geinitz <henning@meier-geinitz.de>
|
||||
|
||||
* frontend/saned.c: Fixed NULL string crash.
|
||||
* REAME.linux: Added some more details about hotplug and Gentoo
|
||||
* README.linux: Added some more details about hotplug and Gentoo
|
||||
problems.
|
||||
* NEWS: Updated for 1.0.15.
|
||||
|
||||
|
@ -34,7 +37,7 @@
|
|||
2004-10-14 Ullrich Sigwanz <usigwanz@freesurf.ch>
|
||||
|
||||
* backend/niash.c: removing a non-ANSI conform comma.
|
||||
adapting the gammma conversion.
|
||||
adapting the gammma conversion.
|
||||
|
||||
2004-10-14 Gerhard Jaeger <gerhard@gjaeger.de>
|
||||
|
||||
|
|
|
@ -18,7 +18,7 @@ sm3600 backend, disable sm3600 in dll.conf if you don't need it.
|
|||
|
||||
Backends that use the function "fork" may not work at least with USB scanners.
|
||||
That's a limitation of MacOS X (doesn't use file descriptors for USB access).
|
||||
Some backends have been modified to use threads on MAcOS X qand should
|
||||
Most backends have been modified to use threads on MacOS X and should
|
||||
work. Others don't use fork at all. Both types of backends should work with
|
||||
MacOS X. Changing the backends to use threads is an ongoing effort.
|
||||
|
||||
|
@ -29,8 +29,6 @@ testing. Please send failure and success reports to the sane-devel mailing
|
|||
list. At least the Epson Perfection 1640SU and the CANON IX-06015C (CanoScan
|
||||
600) are reported to work.
|
||||
|
||||
sane-find-scanner is not able to find SCSI scanners on MacOS X yet.
|
||||
|
||||
USB-scanners:
|
||||
-------------
|
||||
Work with libusb. Very limited testing until now. Try "sane-find-scanner -v -v"
|
||||
|
@ -40,12 +38,16 @@ and 2450 Photo.
|
|||
|
||||
There are some known problems with libusb:
|
||||
|
||||
- Older libusb versions return a wrong number of bytes written. Most backends
|
||||
- Older libusb versions return the wrong number of bytes written. Most backends
|
||||
will return an error and won't work. Update your version of libusb.
|
||||
|
||||
- Sometimes libusb doesn't detect your scanner. Try setting the environment
|
||||
variable SANE_DEBUG_SANEI_USB to 255 (e.g. "setenv SANE_DEBUG_SANEI_USB 255"
|
||||
or "export SANE_DEBUG_SANEI_USB=255) before running scanimage -L.
|
||||
- Set configuration doesn't reclaim the interface. This is important for the
|
||||
sm3600 backend.
|
||||
|
||||
- Libusb sets only the completion timeouts, but not the no data timeouts.
|
||||
|
||||
A patch for these problems is available at
|
||||
https://sourceforge.net/tracker/?group_id=1674 request ID 1044204
|
||||
|
||||
Parport-scanners:
|
||||
-----------------
|
||||
|
|