kopia lustrzana https://gitlab.com/sane-project/backends
Include updates from backend version 0.9 (from
karsten.festag@t-online.de (Karsten Festag)). Henning Meier-Geinitz <henning@meier-geinitz.de>DEVEL_2_0_BRANCH-1
rodzic
f6c81bd30c
commit
131aafb1ff
|
@ -1,5 +1,7 @@
|
|||
.TH sane-microtek2 5 "06 Nov 1998"
|
||||
.IX sane-microtek2
|
||||
. .IX sane-microtek2
|
||||
." Process this file with
|
||||
." groff -man -Tascii sane-microtek2
|
||||
.TH sane-microtek2 5 "19 May 2001"
|
||||
.SH NAME
|
||||
sane-microtek2 - SANE backend for Microtek scanners with SCSI-2 command set
|
||||
.SH DESCRIPTION
|
||||
|
@ -7,170 +9,299 @@ The
|
|||
.B sane-microtek2
|
||||
library implements a SANE (Scanner Access Now Easy) backend that
|
||||
provides access to some Microtek scanners with a SCSI-2 command set.
|
||||
This backend should be considered alpha.
|
||||
This backend can be considered alpha. Some scanner models are reported to work
|
||||
well, others not.
|
||||
.PP
|
||||
There exists a different backend for Microtek scanners with SCSI-1
|
||||
command set. Refer to sane-microtek(5) for details.
|
||||
There exists a different backend for Microtek scanners with SCSI-1 command
|
||||
set.
|
||||
Refer to sane-microtek(5) for details.
|
||||
.PP
|
||||
At present, the following
|
||||
scanners are known positively to work with this backend:
|
||||
And there is work in progress for the ScanMaker 3600.
|
||||
See http://sourceforge.net/projects/sm3600
|
||||
.PP
|
||||
.RS
|
||||
Vendor Product id: Remark:
|
||||
At present, the following scanners are known positively to work with this
|
||||
backend:
|
||||
.PP
|
||||
Vendor Product id: Remark
|
||||
.br
|
||||
-------- -------------- -------------
|
||||
.br
|
||||
Microtek E3+ Parport and SCSI
|
||||
.br
|
||||
Microtek X6 SCSI
|
||||
.br
|
||||
Microtek X6EL SCSI
|
||||
.br
|
||||
Microtek X6USB USB
|
||||
.br
|
||||
Microtek ScanMaker V300 Parport and SCSI
|
||||
.br
|
||||
Microtek ScanMaker V310 Parport and SCSI
|
||||
.br
|
||||
Microtek ScanMaker V600 Parport and SCSI
|
||||
.br
|
||||
Microtek ScanMaker 330 SCSI
|
||||
.br
|
||||
Microtek ScanMaker 630 SCSI
|
||||
.br
|
||||
Microtek ScanMaker 636 SCSI
|
||||
.br
|
||||
Microtek ScanMaker 9600XL SCSI; only flatbed mode?
|
||||
.br
|
||||
Microtek Phantom 330CX Parport
|
||||
.br
|
||||
-------- -------------- -----------
|
||||
.br
|
||||
Microtek E3plus all modes ok
|
||||
.br
|
||||
Microtek X6 all modes ok
|
||||
.br
|
||||
Microtek ScanMaker 330 all modes ok
|
||||
.br
|
||||
Microtek ScanMaker 630 all modes ok
|
||||
.br
|
||||
Microtek ScanMaker 636 all modes ok
|
||||
.br
|
||||
Microtek Phantom 636 all modes ok
|
||||
.br
|
||||
Vobis HighScan all modes ok
|
||||
.RE
|
||||
.PP
|
||||
If you own a Microtek scanner with SCSI-2 interface other than the ones
|
||||
listed above, it may or may not work with SANE!
|
||||
Microtek SlimScan C3 Parport
|
||||
.br
|
||||
Microtek Phantom 636 SCSI
|
||||
.br
|
||||
Microtek Phantom 636CX Parport
|
||||
.br
|
||||
Microtek V6USL SCSI (and USB ???)
|
||||
.br
|
||||
Vobis HighScan SCSI (E3+ based models)
|
||||
.br
|
||||
Scanport? SQ300 Parport?
|
||||
.br
|
||||
Scanpaq SQ2030 Parport
|
||||
.PP
|
||||
Additional information can be found at
|
||||
.B www.mostang.com/sane/
|
||||
.
|
||||
If you own a Microtek scanner with SCSI-2 interface other than the ones
|
||||
listed
|
||||
above, it may or may not work with SANE! Because equal scanners are sold under
|
||||
different names in different countries your model may be equivalent to one of
|
||||
the above.
|
||||
.PP
|
||||
The parport scanners work with the ppscsi + onscsi kernel modules.
|
||||
.PP
|
||||
If you try your scanner for the first time keep an eye on it. If it gets
|
||||
commands that it doesn't understand the scanhead may go beyond the scan area.
|
||||
The scanner then makes strange noises. In this case immedieately switch off
|
||||
the scanner or disconnect its power cable to prevent damages!
|
||||
.PP
|
||||
If your scanner is a different one than the models mentioned above and it is
|
||||
working please tell the author about it. It would be nice if you add a logfile
|
||||
to this information (creation of the logfile: see below).
|
||||
.PP
|
||||
If your scanner is not working properly you also should create a logfile and
|
||||
send it to the author. He will use the information to improve the backend and
|
||||
possibly make your scanner work.
|
||||
.PP
|
||||
.br
|
||||
How to create the logfile?
|
||||
.TP
|
||||
- put the line
|
||||
.br
|
||||
"option dump 2" into your
|
||||
.I microtek2.conf
|
||||
file or change the existing "option dump" to "2"
|
||||
.TP
|
||||
- in a terminal (bash) type
|
||||
.br
|
||||
"export SANE_DEBUG_MICROTEK2=30" and then
|
||||
.br
|
||||
"scanimage -l0 -t0 -x100 -y20 2>scan.log >sout.pnm"
|
||||
.br
|
||||
You get two files: scan.log contains the logfile and sout.pnm the scanned
|
||||
image (if there was scanned something). Zip them before sending.
|
||||
|
||||
.SH "FRONTEND OPTIONS"
|
||||
This backend dynamically enables the options for the frontend,
|
||||
that are supported by the scanner in dependence of the scanning-mode
|
||||
and other options. Not supported options are disabled.
|
||||
.PP
|
||||
This backend dynamically enables the options for the frontend, that are
|
||||
supported by the scanner in dependence of the scanning-mode and other
|
||||
options.
|
||||
Not supported options are disabled.
|
||||
.PP
|
||||
The following options are supported by the Microtek2-driver:
|
||||
.PP
|
||||
.PP
|
||||
Color, grayscale, halftone and lineart scans.
|
||||
.PP
|
||||
.PP
|
||||
Highlight, midtone, shadow, contrast, brightness, exposure time control,
|
||||
gamma correction, threshold (dependent of the scan mode)
|
||||
.PP
|
||||
gamma correction, threshold (dependent of the scan mode and the scanner
|
||||
capabilities)
|
||||
.PP
|
||||
Transparency media adapter, automatic document feeder
|
||||
.PP
|
||||
Additional options can be enabled or disabled in the
|
||||
.I microtek2.conf
|
||||
file. See the configuration section of this manpage.
|
||||
|
||||
.SH "DEVICE NAMES"
|
||||
This backend expects device names of the form:
|
||||
.PP
|
||||
.PP
|
||||
.RS
|
||||
.IR special
|
||||
.I special
|
||||
.RE
|
||||
.PP
|
||||
.PP
|
||||
Where
|
||||
.I special
|
||||
is the UNIX path-name for the special device that corresponds to the
|
||||
scanner. The special device name must be a generic SCSI device or a
|
||||
symlink to such a device. Under Linux, such a device name could be
|
||||
.IR /dev/sga
|
||||
.I /dev/sga
|
||||
or
|
||||
.IR /dev/sge ,
|
||||
.I /dev/sge
|
||||
for example.
|
||||
.SH CONFIGURATION
|
||||
.SH "CONFIGURATION"
|
||||
The configuration file for this backend resides in
|
||||
.IR @CONFIGDIR@/microtek2.conf .
|
||||
.I @CONFIGDIR@/microtek2.conf
|
||||
.
|
||||
Its contents is a list of device names that correspond to Microtek
|
||||
scanners with SCSI-2 interface. Empty lines and lines starting with
|
||||
a hash mark (#) are ignored.
|
||||
.PP
|
||||
The configuration file may also contain options. Currently two options are
|
||||
supported:
|
||||
.PP
|
||||
.PP
|
||||
The configuration file may also contain options. Global options that are valid
|
||||
for all devices are placed above the device names. Device-specific options
|
||||
are
|
||||
placed under the device name. Currently the following options are supported:
|
||||
.PP
|
||||
.RS
|
||||
option dump <n>
|
||||
.br
|
||||
.br
|
||||
option strip-height <n>
|
||||
.br
|
||||
option no-backtrack-option <on/off>
|
||||
.br
|
||||
option lightlid-35 <on/off>
|
||||
.br
|
||||
option toggle-lamp <on/off>
|
||||
.br
|
||||
option lineart-autoadjust <on/off>
|
||||
.br
|
||||
option backend-calibration <on/off>
|
||||
.RE
|
||||
.PP
|
||||
If
|
||||
.PP
|
||||
.I option dump <n>
|
||||
is enabled additional informations about the SCSI
|
||||
commands that are sent to the scanner are printed to stderr. This option
|
||||
is primarily useful for debugging purpose.
|
||||
.PP
|
||||
enables printing of additional information about the SCSI commands that are sent to
|
||||
the scanner to stderr. This option is primarily useful for debugging purpose.
|
||||
This option has to be a global option and is best placed at the top of the
|
||||
.I microtek2.conf
|
||||
file.
|
||||
.PP
|
||||
If n=1 the contents of the command blocks
|
||||
and the results for the INQUIRY and READ SCANNER ATTRIBUTES command are
|
||||
printed to stderr.
|
||||
.PP
|
||||
.PP
|
||||
If n=2 the contents of the command blocks for all other SCSI commands are
|
||||
printed to stderr, too. If n=3 the contents of the gamma table is
|
||||
printed, too. If n=4 all scan data is additionally printed to stderr.
|
||||
.PP
|
||||
.PP
|
||||
The default is n=1.
|
||||
.PP
|
||||
The
|
||||
.PP
|
||||
.I option strip-height <n>
|
||||
, where <n> is a floating point number, limits the amount of data that is
|
||||
read from the scanner with one read command.
|
||||
The unit is inch and <n> defaults to 1.0,
|
||||
if this option is not set in the configuration file. If less than <n> inch
|
||||
of data fit into the SCSI buffer, then the smaller value is used and this
|
||||
option has no effect.
|
||||
.PP
|
||||
The unit is inch and <n> defaults to 1.0, if this option is not set in the
|
||||
configuration file. If less than <n> inch of data fit into the SCSI buffer,
|
||||
then the smaller value is used and this option has no effect.
|
||||
.PP
|
||||
If your system has a big SCSI buffer and you want to make use of the whole
|
||||
buffer, increase the value for <n>. For example, if <n> is set to 14.0,
|
||||
no restrictions apply for scanners with a letter, legal or A4 sized
|
||||
scan area.
|
||||
.PP
|
||||
At present the options apply to all devices in the configuration file and
|
||||
cannnot be set on a per device basis.
|
||||
.PP
|
||||
no restrictions apply for scanners with a letter, legal or A4 sized scan area.
|
||||
.PP
|
||||
.PP
|
||||
The following options enable or disable additional frontend options. If an
|
||||
option is set to <on> an appropriate option will appear in the frontend.
|
||||
.PP
|
||||
.I option no-backtrack-option <on/off>
|
||||
prevents the scanner head from moving backwards between the read commands.
|
||||
This
|
||||
speeds up scanning. Try it.
|
||||
.PP
|
||||
.I option lightlid-35 <on/off>
|
||||
If you use the LightLid-35 transparency adapter this option switches off the
|
||||
flatbed lamp during the scan.
|
||||
.PP
|
||||
.I option toggle-lamp <on/off>
|
||||
You get a button in the frontend where you can switch on and off the flatbed
|
||||
lamp.
|
||||
.PP
|
||||
.I option lineart-autoadjust <on/off>
|
||||
You can tell the backend to try to determine a good value for the lineart
|
||||
threshold.
|
||||
.PP
|
||||
.I option backend-calibration <on/off>
|
||||
Some scanners (e.g. Phantom 330CX and 636CX) need to have calibrated the data
|
||||
by the backend. Try this option if you see vertical stripes in your pictures.
|
||||
.PP
|
||||
A sample configuration file is shown below:
|
||||
.PP
|
||||
.PP
|
||||
.RS
|
||||
option dump 1
|
||||
.br
|
||||
.br
|
||||
option strip-height 1.0
|
||||
.br
|
||||
.br
|
||||
/dev/scanner
|
||||
.br
|
||||
.br
|
||||
option no-backtrack-option on
|
||||
.br
|
||||
# this is a comment
|
||||
.br
|
||||
.br
|
||||
/dev/sge
|
||||
.br
|
||||
option lightlid-35 on
|
||||
.RE
|
||||
|
||||
This backend also supports the new configuration file format which makes
|
||||
it easier to detect scanners under Linux. If you have only one scanner it
|
||||
would be best to use the configuration file for this backend, that
|
||||
is distributed with SANE. This file is shown below:
|
||||
.PP
|
||||
would be best to use the following configuration file for this backend:
|
||||
.PP
|
||||
.RS
|
||||
option dump 1
|
||||
.br
|
||||
.br
|
||||
option strip-height 14.0
|
||||
.br
|
||||
.br
|
||||
option no-backtrack-option on
|
||||
.br
|
||||
option backend-calibration on
|
||||
.br
|
||||
option lightlid-35 on
|
||||
.br
|
||||
option toggle-lamp on
|
||||
.br
|
||||
option lineart-autoadjust on
|
||||
.br
|
||||
scsi * * Scanner
|
||||
.RE
|
||||
|
||||
In this case all SCSI-Scanners should be detected automatically.
|
||||
In this case all SCSI-Scanners should be detected automatically because of the
|
||||
.PP
|
||||
scsi * * Scanner
|
||||
.PP
|
||||
line.
|
||||
|
||||
.SH FILES
|
||||
.TP
|
||||
.SH "FILES"
|
||||
.TP
|
||||
.I @CONFIGDIR@/microtek2.conf
|
||||
The backend configuration file.
|
||||
.TP
|
||||
.TP
|
||||
.I @LIBDIR@/libsane-microtek2.a
|
||||
The static library implementing this backend.
|
||||
.TP
|
||||
.TP
|
||||
.I @LIBDIR@/libsane-microtek2.so
|
||||
The shared library implementing this backend (present on systems that
|
||||
support dynamic loading).
|
||||
.SH ENVIRONMENT
|
||||
.TP
|
||||
.SH "ENVIRONMENT"
|
||||
.TP
|
||||
.B SANE_DEBUG_MICROTEK2
|
||||
If the library was compiled with debug support enabled, this
|
||||
environment variable controls the debug level for this backend. E.g.,
|
||||
a value of 128 requests all debug output to be printed. Smaller
|
||||
a value of 255 requests all debug output to be printed. Smaller
|
||||
levels reduce verbosity. To see error messages on stderr set
|
||||
SANE_DEBUG_MICROTEK2 to 1 (Remark: The whole debugging levels should
|
||||
be better revised).
|
||||
.br
|
||||
.br
|
||||
E.g. just say:
|
||||
.br
|
||||
.br
|
||||
export SANE_DEBUG_MICROTEK2=128
|
||||
.SH "SEE ALSO"
|
||||
sane-scsi(5)
|
||||
.SH AUTHOR
|
||||
Bernd Schroeder
|
||||
sane-scsi(5), sane(7)
|
||||
.SH "AUTHORS"
|
||||
Bernd Schroeder (not active anymore)
|
||||
.br
|
||||
Karsten Festag karsten.festag@t-online.de
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
|
|