@ -48,8 +48,8 @@ SECT5 = sane-abaton.5 sane-agfafocus.5 sane-apple.5 sane-as6e.5 sane-dll.5 \
|
||||||
sane-snapscan.5 sane-canon.5 sane-coolscan.5 sane-bh.5 sane-dc240.5 \
|
sane-snapscan.5 sane-canon.5 sane-coolscan.5 sane-bh.5 sane-dc240.5 \
|
||||||
sane-umax_pp.5 sane-umax1220u.5 sane-sm3600.5 sane-usb.5 \
|
sane-umax_pp.5 sane-umax1220u.5 sane-sm3600.5 sane-usb.5 \
|
||||||
sane-mustek_usb.5 sane-sceptre.5 sane-canon_pp.5 sane-canon630u.5 \
|
sane-mustek_usb.5 sane-sceptre.5 sane-canon_pp.5 sane-canon630u.5 \
|
||||||
sane-teco1.5 sane-teco3.5 sane-test.5 sane-sp15c.5 sane-coolscan2.5 \
|
sane-teco1.5 sane-teco2.5 sane-teco3.5 sane-test.5 sane-sp15c.5 \
|
||||||
sane-hpsj5s.5
|
sane-coolscan2.5 sane-hpsj5s.5
|
||||||
SECT7 = sane.7
|
SECT7 = sane.7
|
||||||
MANPAGES = $(SECT1) $(SECT5) $(SECT7)
|
MANPAGES = $(SECT1) $(SECT5) $(SECT7)
|
||||||
READMES = README AUTHORS COPYING ChangeLog LEVEL2 LICENSE NEWS PROBLEMS \
|
READMES = README AUTHORS COPYING ChangeLog LEVEL2 LICENSE NEWS PROBLEMS \
|
||||||
|
@ -85,8 +85,8 @@ DISTFILES = Makefile.in backend-writing.txt descriptions.txt \
|
||||||
sane-st400.man sane-tamarack.man sane-umax.man sane-umax1220u.man \
|
sane-st400.man sane-tamarack.man sane-umax.man sane-umax1220u.man \
|
||||||
sane-umax_pp.man sane-usb.man sane-v4l.man sane.man sane.png \
|
sane-umax_pp.man sane-usb.man sane-v4l.man sane.man sane.png \
|
||||||
sane.tex saned.man scanimage.man sane-sceptre.man sane-canon_pp.man \
|
sane.tex saned.man scanimage.man sane-sceptre.man sane-canon_pp.man \
|
||||||
sane-teco1.man sane-teco3.man sane-test.man sane-sp15c.man sane-hpsj5s.man \
|
sane-teco1.man sane-teco2.man sane-teco3.man sane-test.man sane-sp15c.man \
|
||||||
gamma4scanimage.man
|
sane-hpsj5s.man gamma4scanimage.man
|
||||||
|
|
||||||
.PHONY: all clean depend dist distclean html html-man install \
|
.PHONY: all clean depend dist distclean html html-man install \
|
||||||
install-mostang sane-html uninstall
|
install-mostang sane-html uninstall
|
||||||
|
|
|
@ -0,0 +1,167 @@
|
||||||
|
.TH sane-teco2 5 "19 March 2002"
|
||||||
|
.IX sane-teco2
|
||||||
|
.SH NAME
|
||||||
|
sane-teco2 - SANE backend for TECO / RELISYS scanners
|
||||||
|
.SH DESCRIPTION
|
||||||
|
The
|
||||||
|
.B sane-teco2
|
||||||
|
library implements a SANE (Scanner Access Now Easy) backend that
|
||||||
|
provides access to some TECO SCSI flatbed scanners. This backend
|
||||||
|
should be considered
|
||||||
|
.B alpha-quality
|
||||||
|
software! TECO scanners are sold under
|
||||||
|
various brands like Relisys, Piotech, TRUST. This backend may or
|
||||||
|
may not support yours.
|
||||||
|
.PP
|
||||||
|
The scanners that should work with this backend are:
|
||||||
|
.PP
|
||||||
|
.RS
|
||||||
|
Vendor Model TECO model status
|
||||||
|
.br
|
||||||
|
---------------------- -------------- -----------
|
||||||
|
.br
|
||||||
|
Relisys Scorpio Super 3 VM3575 tested
|
||||||
|
Apollo Express 6 VM656A tested
|
||||||
|
Scorpio Pro-S VM6586 tested
|
||||||
|
|
||||||
|
.RE
|
||||||
|
|
||||||
|
Note that the untested scanner will not be directly supported. You
|
||||||
|
should contact the author for that.
|
||||||
|
|
||||||
|
The TECO VM number can usually be found at the back of the
|
||||||
|
scanner. It is also part of the FCC ID.
|
||||||
|
|
||||||
|
The options the backend supports can either be selected through
|
||||||
|
command line options to programs like scanimage or through GUI
|
||||||
|
elements in xscanimage or xsane.
|
||||||
|
|
||||||
|
.br
|
||||||
|
If you have any success with a scanner not listed here, or if you have
|
||||||
|
any strange behavior, please report to the backend maintainer or to
|
||||||
|
the SANE mailing list.
|
||||||
|
|
||||||
|
Valid command line options and their syntax can be listed by using
|
||||||
|
.RS
|
||||||
|
scanimage --help -d teco2
|
||||||
|
.RE
|
||||||
|
|
||||||
|
.TP
|
||||||
|
.B Scan Mode
|
||||||
|
|
||||||
|
.TP
|
||||||
|
.B --mode
|
||||||
|
selects the basic mode of operation of the scanner valid choices are
|
||||||
|
.I Black & White
|
||||||
|
,
|
||||||
|
.I Grayscale
|
||||||
|
and
|
||||||
|
.I Color
|
||||||
|
The Black & White mode is black and white only (1 bit). Grayscale
|
||||||
|
will produce 256 levels of gray (8 bits). Color will produce a 24 bits
|
||||||
|
color image.
|
||||||
|
|
||||||
|
.TP
|
||||||
|
.B --resolution
|
||||||
|
selects the resolution for a scan. The scanner can do all resolutions
|
||||||
|
between 1 and 600, in increments of 1.
|
||||||
|
|
||||||
|
|
||||||
|
.TP
|
||||||
|
.B Geometry options
|
||||||
|
|
||||||
|
.TP
|
||||||
|
.B -l -t -x -y
|
||||||
|
control the scan area: -l sets the top left x coordinate, -t the top
|
||||||
|
left y coordinate, -x selects the width and -y the height of the scan
|
||||||
|
area. All parameters are specified in millimeters by default.
|
||||||
|
|
||||||
|
|
||||||
|
.TP
|
||||||
|
.B Enhancement options
|
||||||
|
|
||||||
|
.TP
|
||||||
|
.B --custom-gamma
|
||||||
|
(color mode only) allows the user to specify a gamma table (see the
|
||||||
|
next 3 parameters).
|
||||||
|
|
||||||
|
.TP
|
||||||
|
.B --red-gamma-table
|
||||||
|
(color mode only) can be used to download a user defined
|
||||||
|
gamma table for the red channel. The table must be 256 bytes long.
|
||||||
|
|
||||||
|
.TP
|
||||||
|
.B --green-gamma-table
|
||||||
|
(color mode only) can be used to download a user defined
|
||||||
|
gamma table for the green channel. The table must be 256 bytes long.
|
||||||
|
|
||||||
|
.TP
|
||||||
|
.B --blue-gamma-table
|
||||||
|
(color mode only) can be used to download a user defined gamma table
|
||||||
|
for the blue channel. The table must be 256 bytes long.
|
||||||
|
|
||||||
|
|
||||||
|
.TP
|
||||||
|
.B --preview
|
||||||
|
requests a preview scan. The resolution used for that scan is 22 dpi
|
||||||
|
and the scan area is the maximum allowed. The scan mode is user
|
||||||
|
selected. The default is "no".
|
||||||
|
|
||||||
|
|
||||||
|
.SH CONFIGURATION FILE
|
||||||
|
The configuration file @CONFIGDIR@/teco2.conf supports only one information: the device name to use (eg /dev/scanner).
|
||||||
|
|
||||||
|
|
||||||
|
.SH FILES
|
||||||
|
.TP
|
||||||
|
.I @LIBDIR@/libsane-teco2.a
|
||||||
|
The static library implementing this backend.
|
||||||
|
.TP
|
||||||
|
.I @LIBDIR@/libsane-teco2.so
|
||||||
|
The shared library implementing this backend (present on systems that
|
||||||
|
support dynamic loading).
|
||||||
|
|
||||||
|
|
||||||
|
.SH ENVIRONMENT
|
||||||
|
.TP
|
||||||
|
.B SANE_DEBUG_TECO2
|
||||||
|
If the library was compiled with debug support enabled, this
|
||||||
|
environment variable controls the debug level for this backend. E.g.,
|
||||||
|
a value of 128 requests all debug output to be printed. Smaller levels
|
||||||
|
reduce verbosity.
|
||||||
|
|
||||||
|
|
||||||
|
.SH LIMITATIONS
|
||||||
|
The windows TWAIN driver has many more options than this SANE
|
||||||
|
backend. However they are only software adjustments. This backend only
|
||||||
|
implements what the scanner can support.
|
||||||
|
|
||||||
|
|
||||||
|
.SH BUGS
|
||||||
|
|
||||||
|
Plenty. Parts of this backend are still under development.
|
||||||
|
|
||||||
|
|
||||||
|
.SH "SEE ALSO"
|
||||||
|
|
||||||
|
sane\-scsi(5), scanimage(1), xscanimage(1), xsane(1), sane(7)
|
||||||
|
|
||||||
|
|
||||||
|
.SH AUTHOR
|
||||||
|
|
||||||
|
The package is actively maintained by Frank Zago.
|
||||||
|
http://fz.eryx.net/sane/#teco2
|
||||||
|
|
||||||
|
.SH CREDITS
|
||||||
|
|
||||||
|
Thanks to:
|
||||||
|
.TP
|
||||||
|
Gerard Klaver for his relentless VM3575 testings.
|
||||||
|
.TP
|
||||||
|
Mark Plowman for providing the first SCSI traces from a VM3575.
|
||||||
|
.TP
|
||||||
|
Andreas Klaedtke for providing the first SCSI traces from a VM6586 and for his testing, and to Stefan von Dombrowski for his testing.
|
||||||
|
.TP
|
||||||
|
Nicolas Peyresaubes for providing the first SCSI traces from a VM656A and for his testing.
|
||||||
|
.TP
|
||||||
|
Dave Parker for testing the support for the VM6575.
|
|
@ -262,9 +262,10 @@ sane-st400(5) for details.
|
||||||
The SANE tamarack backend supports Tamarack Artiscan flatbed scanners. See
|
The SANE tamarack backend supports Tamarack Artiscan flatbed scanners. See
|
||||||
sane-tamarack(5) for details.
|
sane-tamarack(5) for details.
|
||||||
.TP
|
.TP
|
||||||
.B teco1 teco3
|
.B teco1 teco2 teco3
|
||||||
The SANE teco1 and teco3 backends support some TECO scanners, usually
|
The SANE teco1, teco2 and teco3 backends support some TECO scanners,
|
||||||
sold under the RELISYS name. See sane-teco1(5) and sane-teco3(5) for details.
|
usually sold under the Relisys, Trust, Primax, Piotech, Dextra
|
||||||
|
names. See sane-teco1(5), sane-teco2(5) and sane-teco3(5) for details.
|
||||||
.TP
|
.TP
|
||||||
.B umax
|
.B umax
|
||||||
The sane-umax backend provides access to several UMAX-SCSI-scanners and some
|
The sane-umax backend provides access to several UMAX-SCSI-scanners and some
|
||||||
|
|
Ładowanie…
Reference in New Issue