Also fixed Bugs #300288 and #300196, removed the conflicting Option_Value

now present in sanei_backend.h and made requested clarifications (Bugs #300290,
#300291)
merge-requests/1/head
Rene Rebe 2003-10-28 11:24:21 +00:00
rodzic 8425846c8e
commit 023f7c1e7a
5 zmienionych plików z 60 dodań i 45 usunięć

Wyświetl plik

@ -5,8 +5,11 @@
revision of SANE/Avision. The fixes include: endianess fixes, revision of SANE/Avision. The fixes include: endianess fixes,
calibration code, ADF detection, correct lamp warmup, gamma table calibration code, ADF detection, correct lamp warmup, gamma table
for new ASICs, some workarounds for ASIC variations and the for new ASICs, some workarounds for ASIC variations and the
convertion to use OPT_SOURCE insteat of seperate OPT_ADF and convertion to use OPT_SOURCE instead of seperate OPT_ADF and
OPT_TRANS. OPT_TRANS. Also fixed Bugs #300288 and #300196 and removed
the conflicting Option_Valu now present in sanei_backend.h
* doc/sane-avision.man: made requested clarifications (Bugs #300290,
#300291)
2003-10-28 Gerhard Jaeger <gerhard@gjaeger.de> 2003-10-28 Gerhard Jaeger <gerhard@gjaeger.de>
* doc/sane-plustek.man backend/plustek.conf backend/plustek.c: * doc/sane-plustek.man backend/plustek.conf backend/plustek.c:

Wyświetl plik

@ -48,14 +48,14 @@
command set. command set.
Copyright 2003 by Copyright 2003 by
"René Rebe" <rene.rebe@gmx.net> "René Rebe" <rene@rocklinux.org>
Copyright 2002 by Copyright 2002 by
"René Rebe" <rene.rebe@gmx.net> "René Rebe" <rene@rocklinux.org>
"Jose Paulo Moitinho de Almeida" <moitinho@civil.ist.utl.pt> "Jose Paulo Moitinho de Almeida" <moitinho@civil.ist.utl.pt>
Copyright 1999, 2000, 2001 by Copyright 1999, 2000, 2001 by
"René Rebe" <rene.rebe@gmx.net> "René Rebe" <rene@rocklinux.org>
"Meino Christian Cramer" <mccramer@s.netic.de> "Meino Christian Cramer" <mccramer@s.netic.de>
Additional Contributers: Additional Contributers:
@ -85,7 +85,13 @@
2003-10-28: René Rebe 2003-10-28: René Rebe
* merging with the new SANE CVS, converted the .desc to the new * merging with the new SANE CVS, converted the .desc to the new
format format (Bug #300146)
* some textual changes incl. a rewrite of the sane-avision man-page
(Bugs #300290 and #300291)
* added another name overwrite for the Minolta Dimage Scan Dual II
(Bug #300288)
* fixed config file reading for non-terminated options (Bug #300196)
* removed Option_Value since it is now included in sanei_backend.h
2003-10-04: René Rebe 2003-10-04: René Rebe
* fixed adf model detection bug - could even crash (not functional * fixed adf model detection bug - could even crash (not functional
@ -785,7 +791,7 @@ static Avision_HWEntry Avision_Device_List [] =
{ "MINOLTA", "FS-V1", { "MINOLTA", "FS-V1",
0x0638, 0x026a, 0x0638, 0x026a,
"Minolta", "FS-V1", "Minolta", "Dimage Scan Dual II",
AV_USB, AV_FILM, AV_ONE_CALIB_CMD}, AV_USB, AV_FILM, AV_ONE_CALIB_CMD},
/* comment="1 pass, film-scanner" */ /* comment="1 pass, film-scanner" */
/* status="basic" */ /* status="basic" */
@ -2130,7 +2136,7 @@ attach (SANE_String_Const devname, Avision_ConnectionType con_type,
memcpy (&rev, result + 32, 4); memcpy (&rev, result + 32, 4);
rev [4] = 0; rev [4] = 0;
/* shorten strings ( -1 for last index /* shorten strings (-1 for last index
-1 for last 0; >0 because one char at least) */ -1 for last 0; >0 because one char at least) */
for (i = sizeof (mfg) - 2; i > 0; i--) { for (i = sizeof (mfg) - 2; i > 0; i--) {
if (mfg[i] == 0x20) if (mfg[i] == 0x20)
@ -2163,7 +2169,7 @@ attach (SANE_String_Const devname, Avision_ConnectionType con_type,
if (!found) { if (!found) {
DBG (1, "attach: model is not in the list of supported models!\n"); DBG (1, "attach: model is not in the list of supported models!\n");
DBG (1, "attach: You might want to report this output. To:\n"); DBG (1, "attach: You might want to report this output. To:\n");
DBG (1, "attach: rene@rocklinux.org (Backend author)\n"); DBG (1, "attach: rene@rocklinux.org (the Avision backend author)\n");
status = SANE_STATUS_INVAL; status = SANE_STATUS_INVAL;
goto close_scanner_and_return; goto close_scanner_and_return;
@ -4435,14 +4441,23 @@ sane_init (SANE_Int* version_code, SANE_Auth_Callback authorize)
line); line);
cp = sanei_config_get_string (line, &word); cp = sanei_config_get_string (line, &word);
if (!word || cp == line) { if (!word || cp == line) {
DBG(5, "sane_init: config file line %d: ignoring empty line\n", DBG(5, "sane_init: config file line %d: ignoring empty line\n",
linenumber); linenumber);
free (word); if (word) {
word = NULL; free (word);
word = NULL;
}
continue; continue;
} }
if (!word) {
DBG(1, "sane_init: config file line %d: could not be parsed\n",
linenumber);
continue;
}
if (word[0] == '#') { if (word[0] == '#') {
DBG(5, "sane_init: config file line %d: ignoring comment line\n", DBG(5, "sane_init: config file line %d: ignoring comment line\n",
linenumber); linenumber);

Wyświetl plik

@ -21,6 +21,6 @@ scsi HP
scsi hp scsi hp
scsi /dev/scanner scsi /dev/scanner
usb /dev/usbscanner # usb libusb:002:003
usb /dev/usb/scanner # usb 0x03f0 0x0701

Wyświetl plik

@ -174,13 +174,6 @@ enum Avision_Option
NUM_OPTIONS /* must come last */ NUM_OPTIONS /* must come last */
}; };
typedef union Option_Value
{
SANE_Word w;
SANE_Word *wa; /* word array */
SANE_String s;
} Option_Value;
typedef struct Avision_Dimensions typedef struct Avision_Dimensions
{ {
/* in dpi */ /* in dpi */

Wyświetl plik

@ -3,11 +3,11 @@
.SH NAME .SH NAME
sane-avision \- SANE backend for original Avision and Avision OEM scanners sane-avision \- SANE backend for original Avision and Avision OEM scanners
(HP, Minolta, Mitsubishi, UMAX and possibly more) flatbed scanners (HP, Minolta, Mitsubishi, UMAX and possibly more) flatbed scanners.
.SH ABOUT THIS FILE .SH ABOUT THIS FILE
This file only is a short descripton of the avision-backend for sane! This file is a short descripton for the avision-backend shipped with SANE.
.SH DESCRIPTION .SH DESCRIPTION
The The
@ -16,6 +16,9 @@ library implements a SANE (Scanner Access Now Easy) backend that
provides access to various Avision scanners and the Avision OEM provides access to various Avision scanners and the Avision OEM
scanners labelled by HP, Minolta, Mitsubishi or Fujitsu. scanners labelled by HP, Minolta, Mitsubishi or Fujitsu.
.B I suggest you hold one hand on the power-button of the scanner while you try
the first scans!
.SH CONFIGURATION .SH CONFIGURATION
The configuration file for this backend resides in The configuration file for this backend resides in
@ -25,9 +28,6 @@ Its contents is a list of device names that correspond to Avision and Avision
compatible scanners and backend-options. Empty lines and lines starting with compatible scanners and backend-options. Empty lines and lines starting with
a hash mark (#) are ignored. A sample configuration file is shown below: a hash mark (#) are ignored. A sample configuration file is shown below:
.B I suggest you hold one hand on the power-button of the scanner while you try
the first scans!
# this is a comment # this is a comment
option force-a4 option force-a4
@ -82,32 +82,36 @@ the first scans!
This backend expects device names of the form: This backend expects device names of the form:
.PP .PP
.RS .RS
.I scsi special .I scsi scsi-spec
.I usb special
.I usb usb-sec
.RE .RE
.PP .PP
Where Where
.I special .I scsi-spec
is the path-name for the device that corresponds to a SCSI scanner or is the path-name to a special device or a device ID for the device that
the USB vendor/product ID pair corresponding to the USB scanner. The corresponds to a SCSI scanner. The special device name must be a generic
special device name must be a generic SCSI device or a SCSI device or a symlink to such a device, for example on Linux "/dev/sga"
symlink to such a device. The program or "/dev/sg0". The device ID is the ID returned by the scanner, for example
.IR sane-find-scanner "HP" or "AVISION". See sane-scsi(5) for details.
helps to find out the correct device. Under Linux, such a device name
could be
.I /dev/sg0
or
.IR /dev/sga ,
for example. See sane-scsi(5) for details.
Note: Since the backend now includes native USB access, Note: Since the backend now includes native USB access,
it is no longer needed - even considered obsolete - it is no longer needed - even considered obsolete -
to access the scanner via the SCSI emulation (named to access USB scanner via the SCSI emulation (named
hpusbscsi on Linux) for Avision USB devices such as hpusbscsi on Linux) for Avision USB devices such as
the HP 53xx, HP 74xx or Minolta film-scanners. the HP 53xx, HP 74xx or Minolta film-scanners.
A list with supported devices is built into the avision backend so .I usb-spec
normally specifying an ID should not be necessary. is the USB device name, the vendor/product ID pair or the name used by
libusb corresponding to the USB scanner. For example "0x03f0 0x0701" or
"libusb:002:003". See sane-usb(5) for details.
The program
.IR sane-find-scanner
helps to find out the correct scsi or usb device name.
A list with supported devices is built into the avision backend so
normally specifying an ID should not be necessary.
.SH FILES .SH FILES
.TP .TP
@ -149,9 +153,9 @@ Example:
export SANE_DEBUG_AVISION=7 export SANE_DEBUG_AVISION=7
.SH "SEE ALSO" .SH "SEE ALSO"
sane(7), sane\-scsi(5) sane(7), sane\-scsi(5), sane\-usb(5)
.br .br
http://drocklinux.dyndns.org/rene/avision/index.html http://www.rocklinux-consulting.de/oss/avision/
.SH AUTHOR .SH AUTHOR
René Rebe and Meino Christian Cramer René Rebe and Meino Christian Cramer