<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
|
||
|
<html>
|
||
|
<head>
|
||
|
<meta http-equiv="Content-Type" content="text/html; charset=iso-8859-1">
|
||
|
<meta name="Author" content="Oliver Rauch">
|
||
|
<meta name="Description" content="unix scanner driver for UMAX scanners">
|
||
|
<title>SANE-umax - Configuration</title>
|
||
|
</head>
|
||
|
<body text="#000000" bgcolor="#FFFFFF" link="#0000EF" vlink="#51188E" alink="#FF0000">
|
||
|
|
||
|
|
||
|
<table>
|
||
|
<tr>
|
||
|
<td width=200>
|
||
|
<img SRC="sane-logo.jpg" alt="SANE-logo" hspace=60 align=BOTTOM>
|
||
|
<br>
|
||
|
<img SRC="sane-umax-text.jpg" alt="UMAX-logo" HSPACE=50>
|
||
|
</td>
|
||
|
<td>
|
||
|
<blockquote>
|
||
|
<h1><font color="#009900">Configuration</font></h1>
|
||
|
</blockquote>
|
||
|
</td>
|
||
|
</tr>
|
||
|
</table>
|
||
|
|
||
|
|
||
|
<hr WIDTH="100%">
|
||
|
|
||
|
<table>
|
||
|
<tr>
|
||
|
<td VALIGN=TOP WIDTH="250" BGCOLOR="#E0E0FF">
|
||
|
<br>
|
||
|
<ul>
|
||
|
<li><a href="sane-umax-doc.html">Index</a></li>
|
||
|
|
||
|
<li>
|
||
|
Frontend options:
|
||
|
<ul>
|
||
|
<li><a href="sane-umax-standard-options-doc.html">Standard options</a></li>
|
||
|
<li><a href="sane-umax-advanced-options-doc.html">Advanced options</a></li>
|
||
|
</ul>
|
||
|
</li>
|
||
|
|
||
|
<li>
|
||
|
Supported scanners:
|
||
|
<ul>
|
||
|
<li><a href="sane-umax-powerlook-doc.html">Power Look series</a></li>
|
||
|
<li><a href="sane-umax-mirage-doc.html">Mirage series</a></li>
|
||
|
<li><a href="sane-umax-astra-doc.html">Astra series</a></li>
|
||
|
<li><a href="sane-umax-vista-doc.html">Vista series</a></li>
|
||
|
<li><a href="sane-umax-uc-doc.html">UC series</a></li>
|
||
|
<li><a href="sane-umax-others-doc.html">others</a></li>
|
||
|
<li><a href="sane-umax-not-listed-doc.html">Not listed scanners</a></li>
|
||
|
<li><a href="sane-umax-scanner-clones-doc.html">UMAX scanner clones</a></li>
|
||
|
</ul>
|
||
|
</li>
|
||
|
|
||
|
<li><a href="sane-umax-parport-doc.html">UMAX parallel port scanners</a></li>
|
||
|
<li><a href="sane-umax-config-doc.html">Configuration</a></li>
|
||
|
<li><a href="sane-umax-speed-doc.html">Speed of UMAX scanners</a></li>
|
||
|
<li><a href="http://www.rauch-domain.de/sane-umax">SANE-umax homepage</a></li>
|
||
|
<li><a href="http://www.sane-project.org">SANE homepage</a></li>
|
||
|
<li><a href="http://www.xsane.org/">XSane homepage</a></li>
|
||
|
</ul>
|
||
|
<br>
|
||
|
</td>
|
||
|
|
||
|
|
||
|
<td VALIGN=TOP BGCOLOR="#FFFFFF">
|
||
|
<blockquote>
|
||
|
<br>
|
||
|
<h2>
|
||
|
CONFIGURATION:
|
||
|
</h2>
|
||
|
|
||
|
<blockquote>The configuration file for this backend resides in
|
||
|
<dl>
|
||
|
<dd>
|
||
|
/usr/local/etc/sane.d/umax.conf.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</blockquote>
|
||
|
|
||
|
<blockquote>
|
||
|
Its contents is a list of options and device names that correspond to UMAX
|
||
|
scanners. Empty lines and lines starting with a hash mark (#) are ignored.
|
||
|
A sample configuration file is shown below:
|
||
|
<br>
|
||
|
<dl>
|
||
|
<dd>option scsi-buffer-size-min 65536</dd>
|
||
|
<dd>option scsi-buffer-size-max 131072</dd>
|
||
|
<dd>option scan-lines 40</dd>
|
||
|
<dd>option preview-lines 10</dd>
|
||
|
<dd>option scsi-maxqueue 2</dd>
|
||
|
<dd>option handle-bad-sense-error 0</dd>
|
||
|
<dd>option execute-request-sense 0</dd>
|
||
|
<dd>option force-preview-bit-rgb 0</dd>
|
||
|
<dd>option slow-speed -1</dd>
|
||
|
<dd>option care-about-smearing -1</dd>
|
||
|
<dd>option calibration-full-ccd -1</dd>
|
||
|
<dd>option calibration-width-offset -1</dd>
|
||
|
<dd>option calibration-bytes-pixel -1</dd>
|
||
|
<dd>option invert-shading-data -1</dd>
|
||
|
<dd>option lamp-control-available 0</dd>
|
||
|
<dd>#scsi Vendor Model Type Bus Channel ID LUN</dd>
|
||
|
<dd>scsi UMAX * Scanner * * * * *</dd>
|
||
|
<dd>/dev/scanner</dd>
|
||
|
<dd># this is a comment</dd>
|
||
|
<dd>/dev/sge</dd>
|
||
|
</dl>
|
||
|
</blockquote>
|
||
|
|
||
|
<blockquote>
|
||
|
The special device name must be a generic SCSI device or a
|
||
|
symlink to such a device. To find out to which device your scanner is assigned
|
||
|
and how you have to set the permissions of that device, have a look at
|
||
|
<a href="http://www.sane-project.org/man/sane-scsi.5.html">sane-scsi</a>.
|
||
|
</blockquote>
|
||
|
|
||
|
<blockquote>
|
||
|
When the generic scsi driver of the system supports selection
|
||
|
of scsi buffer sizes the umax backend calculates the scsi buffer
|
||
|
sizes in dependance of the numbers of bytes per scanline.
|
||
|
With <i>scsi-buffer-size-min</i> and <i>scsi-buffer-size-max</i>
|
||
|
the scsi buffer size can be defined in a range between 4KB and 1MB.
|
||
|
Especially the minimum value is very important. If this value is
|
||
|
set too small the backend is not able to send gamma tables to the
|
||
|
scanner or to do a correct color calibration. This may result in
|
||
|
strange color effects. If the minimum value is set too large then
|
||
|
the backend is not able to allocate the requested scsi buffer size
|
||
|
and aborts with out of memory error. The default is 32KB, for
|
||
|
some scanners it should be increased to 64KB.
|
||
|
|
||
|
<p>
|
||
|
The option <i>scan-lines</i> defines the the number of lines that
|
||
|
shall be scanned with one scsi read command for a real scan.
|
||
|
The number of lines that are read with one scsi command for
|
||
|
preview scans are defined by the option <i>preview-lines</i>.
|
||
|
Both have to be in the range between 1 and 65536.
|
||
|
<p>
|
||
|
With the option <i>scsi-maxqueue</i> you can define the number
|
||
|
of scsi commands that shall be queued. UMAX scanners do not
|
||
|
support command queueing - as far as I know. But some scsi controller
|
||
|
drivers do support queueing in the kernel. In this case it does not
|
||
|
make sense to queue more than 2 commands.
|
||
|
<p>
|
||
|
When you are able to do color previews but color scans do not
|
||
|
work you can set the option <i>force-preview-bit-rgb 1</i>.
|
||
|
This always sets the preview bit when acquiring a color scan.
|
||
|
The image quality may be reduced.
|
||
|
<p>
|
||
|
Some scanners (especally very old scanners) may need the options
|
||
|
<i>slow-speed</i> and/or <i>care-about-smearing</i>. The value
|
||
|
-1 uses the value defined by the driver, 0 disables the feature,
|
||
|
1 enables the feature. <b>Do not change these options unless
|
||
|
you really know what you do, you can destroy your scanner
|
||
|
by setting wrong values for this options!!!</b>
|
||
|
<p>
|
||
|
Some scsi drivers (or may be some scanners) do return an invalid
|
||
|
error code when a scsi command is executed. There are different
|
||
|
ways to handle such bad error codes. You can define the behaviour
|
||
|
of the umax-backend by setting the option <i>handle-bad-sense-error</i>
|
||
|
in umax.conf. You can set the following values:<br>
|
||
|
<dl>
|
||
|
<dd>0 : handle as device busy</dd>
|
||
|
<dd>1 : handle as ok</dd>
|
||
|
<dd>2 : handle as i/o error</dd>
|
||
|
<dd>3 : ignore bad error code, continue sense handler</dd>
|
||
|
</dl>
|
||
|
In most cases it does work when this condition is handled as a
|
||
|
device busy state so this is the default (0).
|
||
|
<p>
|
||
|
The option <i>execute-request-sense</i> disables(0) or enables(1)
|
||
|
the scsi command REQUEST_SENSE. The command can be called when the
|
||
|
scanner asks the driver to do calibration. The driver does
|
||
|
not know the required calibration parameters for all scanners.
|
||
|
Some scanners return the needed parameters when the driver
|
||
|
executes the REQUEST_SENSE command. But there is a problem
|
||
|
with the REQUEST_SENSE command on some systems with some
|
||
|
scsi controller drivers. This can cause a system hang.
|
||
|
So the safe way is to disable the REQUEST_SENSE command,
|
||
|
but the driver may not be able to do correct calibration
|
||
|
in this case.
|
||
|
<p>
|
||
|
For some scanners the calibration has to be done by the driver.
|
||
|
For this the driver has to know some values about the calibration
|
||
|
data. When the REQUEST_SENSE command is disabled or the scanner
|
||
|
does not return the correct data the driver needs to know the
|
||
|
correct parameters. For some scanners the parameters are stored
|
||
|
in the driver. When these values are not set correct the image
|
||
|
might look very strange. To be sure that you have a problem
|
||
|
with the calibration please enable debug output.
|
||
|
<p>
|
||
|
<i>calibration-full-ccd</i>:<br>
|
||
|
The calibration can be done for each element of the CCD (1)
|
||
|
or for each pixel of the requested image(0).
|
||
|
The value -1 enables the value defined in the driver.
|
||
|
<p>
|
||
|
<i>calibration-width-offset</i>:<br>
|
||
|
Some scanners use more pixels than calculated by image/CCD
|
||
|
parameters. A value larger or equal 0 defines the offset.
|
||
|
The value -1 enables the value defined in the driver.
|
||
|
<p>
|
||
|
<i>calibration-bytes-pixel</i>:<br>
|
||
|
Some scanners use 1 byte calibration data although the
|
||
|
scanner supports more than 8 bits/pixel. You can define
|
||
|
1 or 2 bytes per pixel calinration data.
|
||
|
The value -1 enables the value defined in the driver.
|
||
|
<p>
|
||
|
<i>invert-shading-data</i>:<br>
|
||
|
Some scanners need inverted shading data (1), others
|
||
|
need original shading data (0).
|
||
|
The value -1 enables the value defined in the driver.
|
||
|
|
||
|
</blockquote>
|
||
|
|
||
|
<h2>
|
||
|
SCSI ADAPTER TIPS:</h2>
|
||
|
|
||
|
<blockquote>
|
||
|
The UMAX-scanners do block the scsi-bus for a few seconds while
|
||
|
scanning. It is not necessary to connect the scanner to its own SCSI-adapter.
|
||
|
But if you need short response time for your SCSI-harddisk (e.g. if your
|
||
|
computer is a file-server), I suggest you use an own SCSI-adapter for your
|
||
|
UMAX-scanner.
|
||
|
</blockquote>
|
||
|
|
||
|
<blockquote>
|
||
|
The SCSI-adapters that are shipped with some Umax-scanners
|
||
|
are very simple ones. I suggest not to use them. If you really want to
|
||
|
try: the UDS-IS11 uses a DTC3181E chip (compatible to NCR5380). On linux
|
||
|
you may have the chance to get it work with the recent g_NCR5380-driver.
|
||
|
The card does not have IRQ/DMA. Try the following option for kernel boot
|
||
|
option:
|
||
|
<p> dtc_3181e=0x280,255
|
||
|
<p> or use the following command:
|
||
|
<p> insmod g_NCR5380 ncr_irq=255
|
||
|
ncr_addr=0x280 dtc_3181e=1
|
||
|
<p> - ncr_irq=255 : no IRQ, no DMA
|
||
|
<br> - ncr_irq=254 : autoprobe IRQ
|
||
|
<br> - ncr_addr : can be: 0x220 0x240 0x280 0x2A0 0x2C0 0x300 0x320 0x340
|
||
|
<br>
|
||
|
<p>
|
||
|
For
|
||
|
<a href="http://support.umax.co.uk/technotes/f096B.htm">information about the umax-scsi-cards</a>
|
||
|
take a look here.
|
||
|
</blockquote>
|
||
|
|
||
|
<blockquote>
|
||
|
See the relevant hardware FAQs and HOWTOs for your platform
|
||
|
for more information.
|
||
|
<br>See also: <a href="http://www.sane-project.org/man/sane-scsi.5.html">sane-scsi</a>
|
||
|
</blockquote>
|
||
|
|
||
|
<h2>FILES:</h2>
|
||
|
|
||
|
<blockquote>
|
||
|
<ul>
|
||
|
<li>The backend configuration file: /usr/local/etc/sane.d/umax.conf</li>
|
||
|
<li>The static library implementing this backend: /usr/local/lib/sane/libsane-umax.a</li>
|
||
|
<li>
|
||
|
The shared library implementing this backend : /usr/local/lib/sane/libsane-umax.so<br>
|
||
|
(present on systems that support dynamic loading)
|
||
|
</li>
|
||
|
</ul>
|
||
|
</blockquote>
|
||
|
|
||
|
<h2>ENVIRONMENT:</h2>
|
||
|
|
||
|
<blockquote>
|
||
|
<ul>
|
||
|
<li>SANE_DEBUG_UMAX</li>
|
||
|
</ul>
|
||
|
</blockquote>
|
||
|
|
||
|
<blockquote>
|
||
|
If the library was compiled with debug support enabled, this
|
||
|
environment variable controls the debug level for this backend. E.g., a
|
||
|
value of 128 requests all debug output to be printed. Smaller levels reduce
|
||
|
verbosity:
|
||
|
</blockquote>
|
||
|
|
||
|
<center>
|
||
|
<table BORDER>
|
||
|
<tr BGCOLOR="#40E0D0">
|
||
|
<td VALIGN=TOP COLSPAN="2"><b><font face="Arial">SANE_DEBUG_UMAX values</font></b></td>
|
||
|
</tr>
|
||
|
|
||
|
<tr>
|
||
|
<td WIDTH="10%">
|
||
|
<address>
|
||
|
<b>Number</b></address>
|
||
|
</td>
|
||
|
|
||
|
<td WIDTH="90%">
|
||
|
<address>
|
||
|
<b>Remark</b></address>
|
||
|
</td>
|
||
|
</tr>
|
||
|
|
||
|
<tr>
|
||
|
<td>
|
||
|
<address>
|
||
|
0</address>
|
||
|
</td>
|
||
|
|
||
|
<td>print important errors (printed each time)</td>
|
||
|
</tr>
|
||
|
|
||
|
<tr>
|
||
|
<td>
|
||
|
<address>
|
||
|
1</address>
|
||
|
</td>
|
||
|
|
||
|
<td>print errors</td>
|
||
|
</tr>
|
||
|
|
||
|
<tr>
|
||
|
<td>2</td>
|
||
|
|
||
|
<td>print sense</td>
|
||
|
</tr>
|
||
|
|
||
|
<tr>
|
||
|
<td>
|
||
|
<address>
|
||
|
3</address>
|
||
|
</td>
|
||
|
|
||
|
<td>print warnings</td>
|
||
|
</tr>
|
||
|
|
||
|
<tr>
|
||
|
<td>4</td>
|
||
|
|
||
|
<td>print scanner-inquiry</td>
|
||
|
</tr>
|
||
|
|
||
|
<tr>
|
||
|
<td>
|
||
|
<address>
|
||
|
5</address>
|
||
|
</td>
|
||
|
|
||
|
<td>print information</td>
|
||
|
</tr>
|
||
|
|
||
|
<tr>
|
||
|
<td>6</td>
|
||
|
|
||
|
<td>print less important information</td>
|
||
|
</tr>
|
||
|
|
||
|
<tr>
|
||
|
<td>7</td>
|
||
|
|
||
|
<td>print called procedures</td>
|
||
|
</tr>
|
||
|
|
||
|
<tr>
|
||
|
<td>8</td>
|
||
|
|
||
|
<td>print reader_process messages</td>
|
||
|
</tr>
|
||
|
|
||
|
<tr>
|
||
|
<td>
|
||
|
<address>
|
||
|
10</address>
|
||
|
</td>
|
||
|
|
||
|
<td>print called sane-init-routines</td>
|
||
|
</tr>
|
||
|
|
||
|
<tr>
|
||
|
<td>
|
||
|
<address>
|
||
|
11</address>
|
||
|
</td>
|
||
|
|
||
|
<td>print called sane-procedures</td>
|
||
|
</tr>
|
||
|
|
||
|
<tr>
|
||
|
<td>
|
||
|
<address>
|
||
|
12</address>
|
||
|
</td>
|
||
|
|
||
|
<td>print sane-infos</td>
|
||
|
</tr>
|
||
|
|
||
|
<tr>
|
||
|
<td>
|
||
|
<address>
|
||
|
13</address>
|
||
|
</td>
|
||
|
|
||
|
<td>print sane option control messages</td>
|
||
|
</tr>
|
||
|
</table></center>
|
||
|
|
||
|
<h4>Example:</h4>
|
||
|
|
||
|
<blockquote>
|
||
|
export SANE_DEBUG_UMAX=8
|
||
|
</blockquote>
|
||
|
|
||
|
<center>
|
||
|
<hr WIDTH="100%">
|
||
|
<br>
|
||
|
<font color="#009900">This page has been changed on 27th. feburary 2001</font>
|
||
|
<br>
|
||
|
<br>
|
||
|
</center>
|
||
|
</blockquote>
|
||
|
|
||
|
</td>
|
||
|
</tr>
|
||
|
</table>
|
||
|
|
||
|
<hr WIDTH="100%">
|
||
|
|
||
|
<blockquote>
|
||
|
Author: <a href="mailto:Oliver.Rauch@rauch-domain.de">Oliver Rauch</a>
|
||
|
</blockquote>
|
||
|
|
||
|
</body>
|
||
|
</html>
|