											2008-07-14 10:49:06 +00:00
										 |  |  | .TH sane\-teco1 5 "14 Jul 2008" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy" | 
					
						
							|  |  |  | .IX sane\-teco1 | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | .SH NAME | 
					
						
							| 
									
										
										
										
											2008-07-14 10:49:06 +00:00
										 |  |  | sane\-teco1 \- SANE backend for TECO / RELISYS scanners | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | .SH DESCRIPTION | 
					
						
							|  |  |  | The | 
					
						
							| 
									
										
										
										
											2008-07-14 10:49:06 +00:00
										 |  |  | .B sane\-teco1 | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | library implements a SANE (Scanner Access Now Easy) backend that | 
					
						
							|  |  |  | provides access to some TECO SCSI flatbed scanners. This backend | 
					
						
							|  |  |  | should be considered | 
					
						
							|  |  |  | .B beta-quality | 
					
						
							|  |  |  | software! TECO scanners are sold under | 
					
						
							| 
									
										
										
										
											2002-08-23 01:59:27 +00:00
										 |  |  | various brands like RELISYS, PIOTECH, TRUST. This backend may or | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | may not support yours. | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | The scanners that should work with this backend are: | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | .RS | 
					
						
							| 
									
										
										
										
											2005-04-12 06:01:14 +00:00
										 |  |  | .ft CR | 
					
						
							|  |  |  | .nf | 
					
						
							| 
									
										
										
										
											2002-08-31 02:54:15 +00:00
										 |  |  |    Vendor Model           TECO model      status | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | ----------------------  --------------  ----------- | 
					
						
							|  |  |  |   Relisys AVEC 2400        VM3520        tested   | 
					
						
							| 
									
										
										
										
											2004-02-08 15:27:55 +00:00
										 |  |  |   Relisys AVEC 2412        VM3520+       tested | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  |   Relisys AVEC 4800        VM4530        untested   | 
					
						
							|  |  |  |   Relisys AVEC 4816        VM4530+       untested   | 
					
						
							|  |  |  |   Relisys RELI 2400        VM3530        untested   | 
					
						
							| 
									
										
										
										
											2002-07-07 19:26:26 +00:00
										 |  |  |   Relisys RELI 2412        VM3530+       tested | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  |   Relisys RELI 2412        VM3530+       untested   | 
					
						
							| 
									
										
										
										
											2004-02-08 15:27:55 +00:00
										 |  |  |   Relisys RELI 4816        VM4540        tested   | 
					
						
							| 
									
										
										
										
											2002-08-23 01:59:27 +00:00
										 |  |  |   Relisys RELI 4830        VM4542        tested | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  |   Relisys RELI 9600        VM6530        untested   | 
					
						
							|  |  |  |   Relisys RELI 9612        VM6530*       untested   | 
					
						
							|  |  |  |   Relisys RELI 9624        VM6530+       untested   | 
					
						
							|  |  |  |   Relisys RELI 9630        VM6540        untested   | 
					
						
							| 
									
										
										
										
											2002-07-07 19:26:26 +00:00
										 |  |  |   Relisys RELI DS15        VM3440        untested   | 
					
						
							|  |  |  |   Relisys RELI DS6         VM3420        untested   | 
					
						
							| 
									
										
										
										
											2002-08-31 02:54:15 +00:00
										 |  |  |   Dextra  DF-600P          VM3510        tested | 
					
						
							| 
									
										
										
										
											2002-08-23 01:59:27 +00:00
										 |  |  |   Dextra  DF-4830T         VM4542        untested | 
					
						
							|  |  |  |   Dextra  DF-1200T+        VM3530+       untested | 
					
						
							|  |  |  |   Dextra  DF-9624          VM6530+       untested | 
					
						
							| 
									
										
										
										
											2005-04-12 06:01:14 +00:00
										 |  |  | .fi | 
					
						
							|  |  |  | .ft R | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | .RE | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Note that the untested scanner will not be directly supported. You | 
					
						
							|  |  |  | should contact the author for that. | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2002-07-07 19:26:26 +00:00
										 |  |  | The TECO VM number can usually be found at the back of the scanner. It | 
					
						
							| 
									
										
										
										
											2008-07-14 10:49:06 +00:00
										 |  |  | is also part of the FCC ID. "sane\-find\-scanner \-v" will also show the | 
					
						
							| 
									
										
										
										
											2002-07-07 19:26:26 +00:00
										 |  |  | scsi inquiry, and if it is a TECO scanner, the name will be there too. | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | 
 | 
					
						
							|  |  |  | The options the backend supports can either be selected through | 
					
						
							|  |  |  | command line options to programs like scanimage or through GUI | 
					
						
							|  |  |  | elements in xscanimage or xsane. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .br | 
					
						
							|  |  |  | If you have any success with a scanner not listed here, or if you have | 
					
						
							|  |  |  | any strange behavior, please report to the backend maintainer or to | 
					
						
							|  |  |  | the SANE mailing list. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Valid command line options and their syntax can be listed by using  | 
					
						
							|  |  |  | .RS | 
					
						
							| 
									
										
										
										
											2008-07-14 10:49:06 +00:00
										 |  |  | scanimage \-\-help \-d teco1 | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | .RE | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .TP | 
					
						
							|  |  |  | .B Scan Mode | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .TP | 
					
						
							| 
									
										
										
										
											2008-07-14 10:49:06 +00:00
										 |  |  | .B \-\-mode | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | selects the basic mode of operation of the scanner valid choices are  | 
					
						
							|  |  |  | .I Black & White | 
					
						
							|  |  |  | , | 
					
						
							|  |  |  | .I Grayscale | 
					
						
							|  |  |  | and | 
					
						
							|  |  |  | .I Color | 
					
						
							|  |  |  | The Black & White mode is black and white only (1 bit). Grayscale | 
					
						
							|  |  |  | will produce 256 levels of gray (8 bits). Color will produce a 24 bits | 
					
						
							|  |  |  | color image. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .TP | 
					
						
							| 
									
										
										
										
											2008-07-14 10:49:06 +00:00
										 |  |  | .B \-\-resolution | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | selects the resolution for a scan. The scanner can do all resolutions | 
					
						
							|  |  |  | between 1 and 600, in increments of 1. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .TP | 
					
						
							|  |  |  | .B Geometry options | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .TP | 
					
						
							| 
									
										
										
										
											2008-07-14 10:49:06 +00:00
										 |  |  | .B \-l \-t \-x \-y  | 
					
						
							|  |  |  | control the scan area: \-l sets the top left x coordinate, \-t the top | 
					
						
							|  |  |  | left y coordinate, \-x selects the width and \-y the height of the scan | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | area. All parameters are specified in millimeters by default. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .TP | 
					
						
							|  |  |  | .B Enhancement options | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .TP | 
					
						
							| 
									
										
										
										
											2008-07-14 10:49:06 +00:00
										 |  |  | .B \-\-custom\-gamma | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | (color mode only) allows the user to specify a gamma table (see the | 
					
						
							|  |  |  | next 3 parameters). | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .TP  | 
					
						
							| 
									
										
										
										
											2008-07-14 10:49:06 +00:00
										 |  |  | .B \-\-red\-gamma\-table  | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | (color mode only) can be used to download a user defined | 
					
						
							|  |  |  | gamma table for the red channel. The table must be 256 bytes long. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .TP  | 
					
						
							| 
									
										
										
										
											2008-07-14 10:49:06 +00:00
										 |  |  | .B \-\-green\-gamma\-table  | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | (color mode only) can be used to download a user defined | 
					
						
							|  |  |  | gamma table for the green channel. The table must be 256 bytes long. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .TP | 
					
						
							| 
									
										
										
										
											2008-07-14 10:49:06 +00:00
										 |  |  | .B \-\-blue\-gamma\-table  | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | (color mode only) can be used to download a user defined gamma table | 
					
						
							|  |  |  | for the blue channel. The table must be 256 bytes long. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .TP | 
					
						
							| 
									
										
										
										
											2008-07-14 10:49:06 +00:00
										 |  |  | .B \-\-dither | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | (Black & White only) select the dither mask to use. Possible values are  | 
					
						
							|  |  |  | .I Line art | 
					
						
							|  |  |  | , | 
					
						
							|  |  |  | .I 2x2 | 
					
						
							|  |  |  | , | 
					
						
							|  |  |  | .I 3x3 | 
					
						
							|  |  |  | , | 
					
						
							|  |  |  | .I 4x4 bayer | 
					
						
							|  |  |  | , | 
					
						
							|  |  |  | .I 4x4 smooth | 
					
						
							|  |  |  | , | 
					
						
							|  |  |  | .I 8x8 bayer | 
					
						
							|  |  |  | , | 
					
						
							|  |  |  | .I 8x8 smooth | 
					
						
							|  |  |  | , | 
					
						
							|  |  |  | .I 8x8 horizontal | 
					
						
							|  |  |  | and | 
					
						
							|  |  |  | .I 8x8 vertical | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .TP  | 
					
						
							| 
									
										
										
										
											2008-07-14 10:49:06 +00:00
										 |  |  | .B \-\-preview | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | requests a preview scan. The resolution used for that scan is 22 dpi | 
					
						
							|  |  |  | and the scan area is the maximum allowed. The scan mode is user | 
					
						
							|  |  |  | selected. The default is "no". | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH CONFIGURATION FILE | 
					
						
							|  |  |  | The configuration file @CONFIGDIR@/teco1.conf supports only one information: the device name to use (eg /dev/scanner). | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH FILES | 
					
						
							|  |  |  | .TP | 
					
						
							| 
									
										
										
										
											2008-07-14 10:49:06 +00:00
										 |  |  | .I @LIBDIR@/libsane\-teco1.a | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | The static library implementing this backend. | 
					
						
							|  |  |  | .TP | 
					
						
							| 
									
										
										
										
											2008-07-14 10:49:06 +00:00
										 |  |  | .I @LIBDIR@/libsane\-teco1.so | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | The shared library implementing this backend (present on systems that | 
					
						
							|  |  |  | support dynamic loading). | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH ENVIRONMENT | 
					
						
							|  |  |  | .TP | 
					
						
							|  |  |  | .B SANE_DEBUG_TECO1 | 
					
						
							|  |  |  | If the library was compiled with debug support enabled, this | 
					
						
							|  |  |  | environment variable controls the debug level for this backend. E.g., | 
					
						
							|  |  |  | a value of 128 requests all debug output to be printed. Smaller levels | 
					
						
							|  |  |  | reduce verbosity. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH LIMITATIONS | 
					
						
							|  |  |  | The windows TWAIN driver has many more options than this SANE | 
					
						
							|  |  |  | backend. However they are only software adjustments. This backend only | 
					
						
							|  |  |  | implements what the scanner can support. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH BUGS | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | None known. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH "SEE ALSO" | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2008-07-14 10:49:06 +00:00
										 |  |  | sane\-scsi(5), scanimage(1), xscanimage(1), xsane(1), sane(7) | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | 
 | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH AUTHOR | 
					
						
							| 
									
										
										
										
											2005-04-12 06:01:14 +00:00
										 |  |  | .TP | 
					
						
							| 
									
										
										
										
											2002-04-08 23:44:16 +00:00
										 |  |  | The package is actively maintained by Frank Zago. | 
					
						
							| 
									
										
										
										
											2005-04-12 06:01:14 +00:00
										 |  |  | .I http://www.zago.net/sane/#teco | 
					
						
							| 
									
										
										
										
											2002-07-07 19:26:26 +00:00
										 |  |  | 
 | 
					
						
							|  |  |  | .SH CREDITS | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | Thanks to Gerard Delafond for the VM4542 support. | 
					
						
							| 
									
										
										
										
											2002-08-31 02:54:15 +00:00
										 |  |  | Thanks to Jean-Yves Simon for the VM3510 support. |