|   | # For documentation see sane-mustek_pp(5) | ||
|  | 
 | ||
|   | # Global options: | ||
|  | # =============== | ||
|   | # | ||
|   | # option no_epp | ||
|  | # | ||
|  | #	    Disable parallel port mode EPP: works around a known bug in | ||
|  | #	    the Linux parport code. Enable this option, if the backend | ||
|  | #	    hangs when trying to access the parallel port in EPP mode: | ||
|  | # | ||
|  | #	          # SANE_DEBUG_SANEI_PA4S2=128 scanimage -L | ||
|  | #	          ... | ||
|  | #  hangs here  -> [sanei_pa4s2] sanei_pa4s2_readbyte: read in EPP mode | ||
|  | #	  | ||
|   | # Scanner definition template: | ||
|   | # ============================ | ||
|   | # | ||
|  | #  scanner <name> <port> <type> | ||
|  | #     option <optname> <optval>? | ||
|  | #     option <optname> <optval>? | ||
|  | #     ... | ||
|  | # | ||
|  | #  where: | ||
|  | # | ||
|  | #     <name> is an arbitrary name for the scanner (eg. Mustek-1200CP) | ||
|  | # | ||
|  | #     <port> is the parallel port to which the scanner is connected | ||
|  | #            Possible values are 0x378, 0x278, and 0x3bc. For Linux, the | ||
|  | #            mapping between ports an numbers is different for kernel | ||
|  | #            version 2.2 and 2.4. Port 0x378 corresponds to lp0 on 2.4 kernel. | ||
|   | #            If you are using libieee1284, you can as well use parport0, etc.. | ||
|  | #	     If you use the magic value * the port is probed. | ||
|   | # | ||
|  | #     <type> is an identification of the scanner type. | ||
|  | #            Possible values are: | ||
|  | #              - cis600    (for Mustek 600CP & OEM versions), | ||
|  | #              - cis1200   (for Mustek 1200CP & OEM versions), | ||
|  | #              - cis1200+  (for Mustek 1200CP+ & OEM versions), | ||
|   | #              - ccd300    (for Mustek 600 III EPP & OEM versions) | ||
|  | #	       - ... more types will be added in the future | ||
|   | #      | ||
|  | #     <optname> is a name of an option, and <optval> an optional value | ||
|  | #               for the option. | ||
|  | #               Currently available options for *CIS* type scanners are: | ||
|  | #                 - top_adjust <value>:  | ||
|  | #                      Vertical adjustment of origin, in millimeter. | ||
|  | #                      Values between -5.0 and +5.0 mm are possible  | ||
|  | #                      (floating point). | ||
|  | #                      Default: 0.0 | ||
|  | #                 - slow_skip:  | ||
|  | #                      Boolean option. Disables fast skipping to the start | ||
|  | #                      of the scan region. May be necessary in case fast | ||
|  | #                      skipping results in inaccuracies. | ||
|  | #                      Default: fast skipping enabled              | ||
|  | #                 - bw <value>: | ||
|  | #                      Black/white discrimination value for lineart scans. | ||
|  | #                      Pixel values below that value are considered black, | ||
|  | #                      others are considered white. Range: 0-255. | ||
|  | #                      Default: 127 | ||
|  | # | ||
|   | #		Currently available options for *CCD* type scanners are: | ||
|  | #		  - wait_bank <value> | ||
|  | #		       usecs to wait for a bank change. Positive integer | ||
|  | #		       values are possible. You shouldn't mess with this | ||
|  | #		       parameter. | ||
|  | #		       Default: 700 | ||
|  | #		  - bw <value> | ||
|  | #                      Black/white discrimination value for lineart scans. | ||
|  | #                      Pixel values below that value are considered black, | ||
|  | #                      others are considered white. Range: 0-255. | ||
|  | #                      Default: 127 | ||
|  | #		  - top <value> | ||
|  | #		       Scanlines to skip to the top area. Positive integer | ||
|  | #		       values are possible. 47 and 56 are values I know of. | ||
|  | #		       Default: 47 | ||
|  | # | ||
|   | # | ||
|  | # Example for a LifeTec LT9350 (Mustek 1200CP clone): | ||
|  | # | ||
|  | #    scanner LT9350 0x378 cis1200 | ||
|  | #       option top_adjust 0 | ||
|  | #       option bw 127 | ||
|  | # | ||
|   | # Example for Mustek 6000P | ||
|  | # | ||
|  | #    scanner 6000P 0x378 ccd300 | ||
|  | #        option top 56 | ||
|  | # | ||
|   | # | ||
|  | # Uncomment/customize to your needs | ||
|  | # | ||
|  | # scanner Mustek-600CP 0x378 cis600 | ||
|  | # scanner Mustek-1200CP 0x378 cis1200 | ||
|  | # scanner Mustek-1200CP+ 0x378 cis1200+ | ||
|   | # scanner Mustek-600-IIIEP 0x378 ccd300 | ||
|  | # | ||
|  | # auto probing: | ||
|   | # | ||
|   | # scanner mustek-cis600 * cis600 | ||
|  | # scanner mustek-cis1200 * cis1200 | ||
|  | # scanner mustek-cis1200+ * cis1200+ | ||
|   | # scanner mustek-ccd300 * ccd300 |