2012-07-04 04:53:50 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.TH  "sane\-genesys"  "5"  "4 Jul 2012"  "@PACKAGEVERSION@"  "SANE Scanner Access Now Easy" 
							 
						 
					
						
							
								
									
										
										
										
											2008-07-14 10:49:06 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.IX  sane\-genesys 
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								.SH  "NAME" 
							 
						 
					
						
							
								
									
										
										
										
											2010-12-26 11:08:01 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								sane\- genesys \-  SANE backend for GL646, GL841, GL843, GL847 and GL124 based USB flatbed scanners
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								.SH  "DESCRIPTION" 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								The
							 
						 
					
						
							
								
									
										
										
										
											2008-07-14 10:49:06 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.B  sane\-genesys 
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								library implements a SANE (Scanner Access Now Easy) backend that provides
							 
						 
					
						
							
								
									
										
										
										
											2011-10-21 05:58:31 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								access to USB flatbed scanners based on the Genesys GL646, GL841, GL843, GL847 and GL124 chips.
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								At present, the following scanners are known to work with this backend:
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.PP  
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RS 
							 
						 
					
						
							
								
									
										
										
										
											2015-09-09 19:25:47 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								Canon LiDE 35/40/50/60/100/110/200/210/220/700
							 
						 
					
						
							
								
									
										
										
										
											2010-01-19 20:38:29 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
									
										
										
										
											2011-10-21 05:58:31 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								Hewlett-Packard HP2300C/HP2400/HP3670/HP3690/G4010/G4050
							 
						 
					
						
							
								
									
										
										
										
											2005-11-20 14:38:40 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
									
										
										
										
											2010-12-26 11:08:01 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								Medion MD5345/MD6228/MD6274
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.br  
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								Panasonic KV-SS080
							 
						 
					
						
							
								
									
										
										
										
											2009-10-06 19:52:54 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
									
										
										
										
											2010-12-27 06:08:44 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								Plustek OpticBook 3600
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
									
										
										
										
											2009-10-06 19:52:54 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								Pentax DSmobile 600
							 
						 
					
						
							
								
									
										
										
										
											2010-01-13 05:50:33 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
									
										
										
										
											2010-06-18 04:42:44 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								Syscan/Ambir DocketPORT 467/485/487/665/685
							 
						 
					
						
							
								
									
										
										
										
											2010-01-30 13:21:48 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
									
										
										
										
											2010-12-26 11:08:01 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								Visioneer OneTouch 7100/Strobe XP100 (rev3)/XP200/XP300/Roadwarrior
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
									
										
										
										
											2012-05-31 19:14:23 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								Xerox Travel Scanner 100, OneTouch 2400
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								.RE 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.PP  
							 
						 
					
						
							
								
									
										
										
										
											2007-08-27 04:58:53 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								This is stable software for supported models. But if you test new or untested scanners, keep
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								your hand at the scanner's plug and unplug it, if the head bumps at the end of
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								the scan area.
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.PP  
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								If you own a scanner other than the ones listed above that works with this
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								backend, please let me know this by sending the scanner's exact model name and
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								the USB vendor and device ids (e.g. from
							 
						 
					
						
							
								
									
										
										
										
											2008-05-15 20:16:51 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.IR  /proc/bus/usb/devices  , 
							 
						 
					
						
							
								
									
										
										
										
											2008-07-14 10:49:06 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.I  sane\-find\-scanner 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								or syslog) to the sane\- devel mailing list. Even if the scanner's name is only
							 
						 
					
						
							
								
									
										
										
										
											2005-07-03 13:58:21 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								slightly different from the models mentioned above, please let me know.
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								.PP  
							 
						 
					
						
							
								
									
										
										
										
											2010-06-18 04:42:44 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								If you own a scanner that isn't detected by the genesys backend but has a GL646,
							 
						 
					
						
							
								
									
										
										
										
											2012-07-04 04:53:50 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								GL841, GL843, GL847 or GL124 chipset, you can try to add it to the backend. 
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								.PP  
							 
						 
					
						
							
								
									
										
										
										
											2009-10-06 19:52:54 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.SH  "CALIBRATION" 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								To give correct image quality, sheet fed scanners need to be calibrated using the
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								calibration sheet sold with the scanner. To do calibration, you must insert this target
							 
						 
					
						
							
								
									
										
										
										
											2014-03-02 18:17:07 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								in the feeder then start calibration either by passing the \- \- calibrate option to scanimage
							 
						 
					
						
							
								
									
										
										
										
											2010-01-13 05:50:33 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								or by clicking on the available 'calibrate' button in the 'advanced options' in a graphical
							 
						 
					
						
							
								
									
										
										
										
											2009-10-06 19:52:54 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								frontend. The result of the calibration is stored in a file in the home directory of the user doing it.
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								If you plug the scanner in another machine or use it with another account, calibration
							 
						 
					
						
							
								
									
										
										
										
											2014-02-20 05:51:38 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								will have to be redone, unles you use the \- \- calibration\- file option.
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								If no home directory is defined,
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								USERAPPPROFILE will be used, then TMPDIR or TMP. If none of these directories exist, the backend will try
							 
						 
					
						
							
								
									
										
										
										
											2015-04-12 07:46:26 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								to write in the current working directory. Flatbed scanners also make use of the calibration file as a cache
							 
						 
					
						
							
								
									
										
										
										
											2014-02-20 05:51:38 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								to avoid calibration before each scan. Calibration file name is the name of the scanner model if only
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								one scanner is detected. In the case of several identical model, the file name will be the name
							 
						 
					
						
							
								
									
										
										
										
											2015-04-12 07:46:26 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								of the logical USB device name. The expiration time manages the time a calibration is valid in cache.
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								A value of -1 means forever, 0 means no cache.
							 
						 
					
						
							
								
									
										
										
										
											2009-10-06 19:52:54 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
									
										
										
										
											2010-01-13 05:50:33 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.SH  EXTRAS  SCAN  OPTIONS 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.B  \- \- lamp\-off\-time  number 
							 
						 
					
						
							
								
									
										
										
										
											2010-09-12 19:40:25 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.RS 
							 
						 
					
						
							
								
									
										
										
										
											2010-01-13 05:50:33 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								        The lamp will be turned off after the given time (in minutes). A value of 0 means that the lamp won't be turned off.
							 
						 
					
						
							
								
									
										
										
										
											2010-09-12 19:40:25 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.RE 
							 
						 
					
						
							
								
									
										
										
										
											2010-01-13 05:50:33 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
									
										
										
										
											2013-08-05 19:27:39 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.B  \- \- threshold  percent 
							 
						 
					
						
							
								
									
										
										
										
											2010-09-12 19:40:25 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.RS 
							 
						 
					
						
							
								
									
										
										
										
											2010-01-13 05:50:33 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
									0..100% (in steps of 1). Select minimum brightness to get a white point. Pixels
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								whith brightness below that value will be scanned as black.
							 
						 
					
						
							
								
									
										
										
										
											2010-09-12 19:40:25 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.RE 
							 
						 
					
						
							
								
									
										
										
										
											2010-01-13 05:50:33 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
									
										
										
										
											2013-08-05 19:27:39 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.B  \- \- brightness  value 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RS 
							 
						 
					
						
							
								
									
										
										
										
											2014-03-02 18:17:07 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
									\- 100..100 (in steps of 1). Set the brightness enhancement. 0 for no enhancement, negative
							 
						 
					
						
							
								
									
										
										
										
											2013-08-05 19:27:39 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								values to decrease brigthness, and positive values to increase it.
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RE 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.B  \- \- contrast  value 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RS 
							 
						 
					
						
							
								
									
										
										
										
											2014-03-02 18:17:07 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
									\- 100..100 (in steps of 1). Set the contrast enhancement. 0 for no enhancement, negative
							 
						 
					
						
							
								
									
										
										
										
											2013-08-05 19:27:39 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								values to decrease contrast, and positive values to increase it.
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RE 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
									
										
										
										
											2010-01-13 05:50:33 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.B  \- \- disable-interpolation  yes|no 
							 
						 
					
						
							
								
									
										
										
										
											2010-09-12 19:40:25 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.RS 
							 
						 
					
						
							
								
									
										
										
										
											2010-01-13 05:50:33 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								        When using high resolutions where the horizontal resolution is smaller than vertical resolution,
							 
						 
					
						
							
								
									
										
										
										
											2012-07-31 01:42:52 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								data is expanded by software to preserve picture geometry. This can be disabled by this option to get
							 
						 
					
						
							
								
									
										
										
										
											2010-01-13 05:50:33 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								real scanned data.
							 
						 
					
						
							
								
									
										
										
										
											2010-09-12 19:40:25 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.RE 
							 
						 
					
						
							
								
									
										
										
										
											2010-01-13 05:50:33 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
									
										
										
										
											2012-08-08 05:39:36 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.B  \- \- disable-dynamic-lineart  yes|no 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RS 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								        Disable use of a software adaptive algorithm to generate lineart and rely on hardware lineart.
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RE 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
									
										
										
										
											2010-01-13 05:50:33 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.B  \- \- color-filter  None|Red|Green|Blue 
							 
						 
					
						
							
								
									
										
										
										
											2010-09-12 19:40:25 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.RS 
							 
						 
					
						
							
								
									
										
										
										
											2010-01-13 05:50:33 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								        When using gray or lineart this option selects the used color. Using a color filter
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								will give a monochrome scan. CIS based scanners can to true gray when no filter (None value) is
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								selected.
							 
						 
					
						
							
								
									
										
										
										
											2010-09-12 19:40:25 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.RE 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
									
										
										
										
											2012-07-04 04:53:50 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.B  \- \- lamp\-off\-scan 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RS 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								        The lamp will be turned off during the scan. Calibration is still done with lamp on.
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RE 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
									
										
										
										
											2013-08-07 04:42:14 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.B  \- \- clear\-calibration 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RS 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								        Clear calibration cache data, triggering a new calibration for the device when the
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								next scan will happen.
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RE 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.B  \- \- calibration\-file 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RS 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								        Specify the calibration file name to use. At least the directory containing the file
							 
						 
					
						
							
								
									
										
										
										
											2014-02-20 05:51:38 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								must exist, since it won't be created. This option is disabled if the backend is ran
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								as root. It maybe used in case of sheet-fed scanners to share a calibration file for several
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								users.
							 
						 
					
						
							
								
									
										
										
										
											2013-08-07 04:42:14 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.RE 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
									
										
										
										
											2015-04-12 07:46:26 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.B  \- \- expiration\-time 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RS 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								        Specify the time (in minutes) a cached calibration is considered valid. If older than the given value, a new
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								calibration is done. A value of -1 means no expiration and cached value are kept forever unless cleared by
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								userwith the calibration clear option. A value of 0 means cache is disabled.
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RE 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
									
										
										
										
											2010-09-12 19:40:25 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.PP 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								Additionally, several 'software' options are exposed by the backend. These
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								are reimplementations of features provided natively by larger scanners, but
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								running on the host computer. This enables smaller machines to have similar
							 
						 
					
						
							
								
									
										
										
										
											2012-07-31 01:42:52 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								capabilities. Please note that these features are somewhat simplistic, and 
							 
						 
					
						
							
								
									
										
										
										
											2010-09-12 19:40:25 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								may not perform as well as the native implementations. Note also that these 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								features all require that the driver cache the entire image in memory. This 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								will almost certainly result in a reduction of scanning speed.
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.PP 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.B  \- \- swcrop  
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RS 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
									Requests the driver to detect the extremities of the paper within the larger 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								image, and crop the empty edges. 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RE 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.PP 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.B  \- \- swdeskew  
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RS 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
									Requests the driver to detect the rotation of the paper within the larger 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								image, and counter the rotation.
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RE 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.PP 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.B  \- \- swdespeck   \- \- despeck  X 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RS 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
									Requests the driver to find and remove dots of X diameter or smaller from the 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								image, and fill the space with the average surrounding color.
							 
						 
					
						
							
								
									
										
										
										
											2011-06-07 19:17:28 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.RE 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.PP 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.B  \- \- swskip  0 ..100%  (in  steps  of  1 )  [0] 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RS 
							 
						 
					
						
							
								
									
										
										
										
											2011-06-08 19:55:59 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								        Request driver to discard pages with low numbers of dark pixels.
							 
						 
					
						
							
								
									
										
										
										
											2011-06-07 19:17:28 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.RE 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.PP 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.B  \- \- swderotate[=(yes|no)]  [no] 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RS 
							 
						 
					
						
							
								
									
										
										
										
											2011-06-08 19:55:59 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								        Request driver to detect and correct 90 degree image rotation.
							 
						 
					
						
							
								
									
										
										
										
											2010-01-13 05:50:33 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
									
										
										
										
											2009-10-06 19:52:54 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.PP 
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								.SH  "SYSTEM ISSUES" 
							 
						 
					
						
							
								
									
										
										
										
											2005-11-24 20:17:43 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								This backend needs libusb-0.1.6 or later installed, and hasn't tested in other
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								configuration than a linux kernel 2.6.9 or higher. However, it should work any
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								system with libusb where the SANE package can be compiled. For
							 
						 
					
						
							
								
									
										
										
										
											2005-07-03 13:58:21 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								setting permissions and general USB information look at
							 
						 
					
						
							
								
									
										
										
										
											2008-07-14 10:49:06 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.BR  sane\-usb  (5). 
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.SH  "CONFIGURATION" 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								The contents of the
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.I  genesys.conf 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								file is a list of usb lines containing vendor and product ids that correspond
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								to USB scanners. The file can also contain option lines.  Empty lines and
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								lines starting with a hash mark (#) are ignored.  The scanners are
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								autodetected by
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.B  usb  vendor_id  product_id 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								statements which are already included into
							 
						 
					
						
							
								
									
										
										
										
											2005-11-24 20:17:43 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.IR  genesys.conf  . 
							 
						 
					
						
							
								
									
										
										
										
											2006-03-21 13:51:18 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								"vendor_id" and "product_id" are hexadecimal numbers that identify the
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								scanner. 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.PP  
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.SH  "FILES" 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.TP  
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.I  @CONFIGDIR@/genesys.conf 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								The backend configuration file (see also description of
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.B  SANE_CONFIG_DIR 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								below).
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.TP  
							 
						 
					
						
							
								
									
										
										
										
											2008-07-14 10:49:06 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.I  @LIBDIR@/libsane\-genesys.a 
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								The static library implementing this backend.
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.TP  
							 
						 
					
						
							
								
									
										
										
										
											2008-07-14 10:49:06 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.I  @LIBDIR@/libsane\-genesys.so 
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								The shared library implementing this backend (present on systems that
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								support dynamic loading).
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.SH  "ENVIRONMENT" 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.TP  
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.B  SANE_CONFIG_DIR 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								This environment variable specifies the list of directories that may
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								contain the configuration file.  Under UNIX, the directories are
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								separated by a colon (`:'), under OS/2, they are separated by a
							 
						 
					
						
							
								
									
										
										
										
											2005-11-24 20:17:43 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								semi-colon (`;').  If this variable is not set, the configuration file
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								is searched in two default directories: first, the current working
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								directory (".") and then in @CONFIGDIR@.  If the value of the
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								environment variable ends with the directory separator character, then
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								the default directories are searched after the explicitly specified
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								directories.  For example, setting
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.B  SANE_CONFIG_DIR 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								to "/tmp/config:" would result in directories "tmp/config", ".", and
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								"@CONFIGDIR@" being searched (in this order).
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.TP  
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.B  SANE_DEBUG_GENESYS 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								If the library was compiled with debug support enabled, this environment
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								variable controls the debug level for this backend.  Higher debug levels
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								increase the verbosity of the output. If the debug level is set to 1 or higher,
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								some debug options become available that are normally hidden. Handle them with
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								care. This will print messages related to core genesys functions.
							 
						 
					
						
							
								
									
										
										
										
											2010-12-26 11:08:01 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.TP 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.B  SANE_DEBUG_GENESYS_LOW 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								This environment variable controls the debug level for low level functions
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								common to all genesys ASICs.
							 
						 
					
						
							
								
									
										
										
										
											2005-11-20 14:38:40 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.TP  
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								.B  SANE_DEBUG_GENESYS_GL646 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								This environment variable controls the debug level for the specific GL646 code
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								part.
							 
						 
					
						
							
								
									
										
										
										
											2005-11-20 14:38:40 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.TP  
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.B  SANE_DEBUG_GENESYS_GL841 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								This environment variable controls the debug level for the specific GL841 code
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								part.
							 
						 
					
						
							
								
									
										
										
										
											2010-06-18 04:42:44 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.TP  
							 
						 
					
						
							
								
									
										
										
										
											2010-09-12 19:40:25 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.B  SANE_DEBUG_GENESYS_GL843 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								This environment variable controls the debug level for the specific GL843 code
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								part.
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.TP  
							 
						 
					
						
							
								
									
										
										
										
											2010-06-18 04:42:44 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.B  SANE_DEBUG_GENESYS_GL847 
							 
						 
					
						
							
								
									
										
										
										
											2010-09-12 19:40:25 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								This environment variable controls the debug level for the specific GL847 code
							 
						 
					
						
							
								
									
										
										
										
											2010-06-18 04:42:44 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								part.
							 
						 
					
						
							
								
									
										
										
										
											2010-12-26 11:08:01 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.TP  
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.B  SANE_DEBUG_GENESYS_GL124 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								This environment variable controls the debug level for the specific GL124 code
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								part.
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
									
										
										
										
											2005-11-20 14:38:40 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								Example (full and highly verbose output for gl646): 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								export SANE_DEBUG_GENESYS=255
							 
						 
					
						
							
								
									
										
										
										
											2005-11-20 14:38:40 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
									
										
										
										
											2010-12-26 11:08:01 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								export SANE_DEBUG_GENESYS_LOW=255
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								export SANE_DEBUG_GENESYS_GL646=255
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
									
										
										
										
											2009-04-29 04:40:58 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.SH  CREDITS 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								  
							 
						 
					
						
							
								
									
										
										
										
											2010-12-26 11:08:01 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								Jack McGill for donating several sheetfed and flatbed scanners, which made possible to add support
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								for them in the genesys backend:
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.RS 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								Hewlett-Packard HP3670
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.br  
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								Visioneer Strobe XP100 (rev3)/XP200/XP300/Roadwarrior
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								Canon LiDE 200
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								Pentax DSmobile 600
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								Syscan/Ambir DocketPORT 467/485/487/665/685
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
									
										
										
										
											2012-05-31 19:14:23 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								Xerox Travel Scanner 100, Onetouch 2400
							 
						 
					
						
							
								
									
										
										
										
											2010-12-26 11:08:01 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.RE 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.TP 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								cncsolutions (http://www.cncsolutions.com.br) sponsored and supported the work on the Panasonic KV-SS080.
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
									
										
										
										
											2012-05-28 06:24:12 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.TP 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								Brian Paavo from Benthic Science Limited for donating a Canoscan LiDE 700F.
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
									
										
										
										
											2015-02-26 21:22:34 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.TP 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								Dany Qumsiyeh for donating a Canoscan LiDE 210 and a LiDE 220.
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
									
										
										
										
											2009-04-29 04:40:58 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								.SH  "SEE ALSO" 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.BR  sane  (7), 
							 
						 
					
						
							
								
									
										
										
										
											2008-07-14 10:49:06 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.BR  sane\-usb  (5) 
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								.br  
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.SH  "AUTHOR" 
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								Oliver Rauch
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.br  
							 
						 
					
						
							
								
									
										
										
										
											2008-07-14 10:49:06 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								Henning Meier-Geinitz <henning@meier\- geinitz.de>
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								.br  
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								Gerhard Jaeger <gerhard@gjaeger.de>
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.br  
							 
						 
					
						
							
								
									
										
										
										
											2007-08-27 04:58:53 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								St\[ 'e]phane Voltz <stef.dev@free.fr>
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								.br  
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								Philipp Schmid <philipp8288@web.de>
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.br  
							 
						 
					
						
							
								
									
										
										
										
											2007-08-27 04:58:53 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								Pierre Willenbrock <pierre@pirsoft.dnsalias.org>
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
									
										
										
										
											2011-06-13 19:52:05 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								Alexey Osipov <simba@lerlan.ru> for HP2400 final support
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
									
										
										
										
											2007-08-27 04:58:53 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.SH  "LIMITATIONS" 
							 
						 
					
						
							
								
									
										
										
										
											2009-04-29 04:40:58 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
									
										
										
										
											2012-08-08 05:39:36 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								Powersaving isn't implemented for gl646 based scanner. Dynamic (emulated from gray data and with dithering) isn't enabled for gl646 scanners. Hardware lineart is limited up to 600 dpi for gl847 based scanners, due to the way image sensors are built.
							 
						 
					
						
							
								
									
										
										
										
											2007-08-27 04:58:53 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
									
										
										
										
											2010-12-26 11:08:01 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.TP 
							 
						 
					
						
							
								
									
										
										
										
											2014-03-02 18:17:07 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								This backend will be much slower if not using libusb\- 1.0. So be sure that sane\- backends is built with the \- \- enable-libusb_1_0 option.
							 
						 
					
						
							
								
									
										
										
										
											2010-12-26 11:08:01 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								.br 
							 
						 
					
						
							
								
									
										
										
										
											2007-08-27 04:58:53 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								.SH  "BUGS" 
							 
						 
					
						
							
								
									
										
										
										
											2011-07-06 19:50:35 +00:00 
										
									 
								 
							 
							
								
									
										 
								
							 
							
								 
							
							
								For the LiDE 200, the scanned data at 4800 dpi is obtained "as is" from sensor. It seems the windows driver does some digital processing
							 
						 
					
						
							
								
							 
							
								
							 
							
								 
							
							
								to improve it, which is not implemented in the backend.
							 
						 
					
						
							
								
									
										
										
										
											2005-06-27 20:07:45 +00:00 
										
									 
								 
							 
							
								
							 
							
								 
							
							
								.PP