											2010-02-11 03:38:37 +00:00
										 |  |  | .TH sane\-kodak 5 "10 Feb 2010" "@PACKAGEVERSION@" "SANE Scanner Access Now Easy" | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | .IX sane\-kodak | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH NAME | 
					
						
							|  |  |  | sane\-kodak \- SANE backend for big Kodak flatbed and ADF scanners | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH DESCRIPTION | 
					
						
							| 
									
										
										
										
											2017-05-27 05:27:22 +00:00
										 |  |  | The | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | .B sane\-kodak | 
					
						
							|  |  |  | library implements a SANE (Scanner Access Now Easy) backend which | 
					
						
							|  |  |  | provides access to large Kodak flatbed and ADF scanners. | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2010-02-11 03:38:37 +00:00
										 |  |  | This document describes backend version 7, which shipped with SANE 1.0.21. | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | 
 | 
					
						
							|  |  |  | .SH SUPPORTED HARDWARE | 
					
						
							| 
									
										
										
										
											2017-05-27 05:27:22 +00:00
										 |  |  | This version should support models which speak the Kodak SCSI and Firewire | 
					
						
							|  |  |  | protocols. The i1860 was used to develop the backend, but other models may | 
					
						
							|  |  |  | work with only minimal modifications. Please see the list at | 
					
						
							| 
									
										
										
										
											2021-02-02 20:58:54 +00:00
										 |  |  | .I http://www.sane\-project.org/sane\-supported\-devices.html | 
					
						
							|  |  |  | for an updated list. | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | 
 | 
					
						
							| 
									
										
										
										
											2017-05-27 05:27:22 +00:00
										 |  |  | If you have a machine not on that list, or reported as 'untested': the best way | 
					
						
							|  |  |  | to determine level of support is to test the scanner directly, or to collect a | 
					
						
							|  |  |  | trace of the windows driver in action.  Please contact the author for help or | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | with test results. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH UNSUPPORTED HARDWARE | 
					
						
							| 
									
										
										
										
											2017-05-27 05:27:22 +00:00
										 |  |  | Most of the recent Kodak consumer or workgroup level machines are based on | 
					
						
							|  |  |  | other chipsets and are not supported by this backend. Some of these scanners | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | may be supported by another backend. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH OPTIONS | 
					
						
							|  |  |  | Effort has been made to expose the basic hardware options, including: | 
					
						
							|  |  |  | .PP | 
					
						
							| 
									
										
										
										
											2021-02-02 20:58:54 +00:00
										 |  |  | .B --source s | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | .RS | 
					
						
							|  |  |  | Selects the source for the scan. Options | 
					
						
							|  |  |  | may include "Flatbed", "ADF Front", "ADF Back", "ADF Duplex". | 
					
						
							|  |  |  | .RE | 
					
						
							|  |  |  | .PP | 
					
						
							| 
									
										
										
										
											2021-02-02 20:58:54 +00:00
										 |  |  | .B --mode m | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | .RS | 
					
						
							|  |  |  | Selects the mode for the scan. Options | 
					
						
							|  |  |  | may include "Lineart", "Halftone", "Gray", and "Color". | 
					
						
							|  |  |  | .RE | 
					
						
							|  |  |  | .PP | 
					
						
							| 
									
										
										
										
											2021-02-02 20:58:54 +00:00
										 |  |  | .B --resolution | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | .RS | 
					
						
							|  |  |  | Controls scan resolution. Available choices may be limited by mode. | 
					
						
							|  |  |  | .RE | 
					
						
							|  |  |  | .PP | 
					
						
							| 
									
										
										
										
											2021-02-02 20:58:54 +00:00
										 |  |  | .BR --tl\-x ", " --tl\-y ", " --br\-x ", "  --br\-y | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | .RS | 
					
						
							| 
									
										
										
										
											2017-05-27 05:27:22 +00:00
										 |  |  | Sets scan area upper left and lower right coordinates. These are renamed | 
					
						
							| 
									
										
										
										
											2021-02-02 20:58:54 +00:00
										 |  |  | .BR -t ", " -l ", " -x ", " -y | 
					
						
							|  |  |  | by some frontends. | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | .RE | 
					
						
							|  |  |  | .PP | 
					
						
							| 
									
										
										
										
											2021-02-02 20:58:54 +00:00
										 |  |  | .BR --page\-width ", " --page\-height | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | .RS | 
					
						
							|  |  |  | Sets paper size. Used by scanner to determine centering of scan | 
					
						
							| 
									
										
										
										
											2021-08-29 23:00:23 +00:00
										 |  |  | coordinates when using the ADF (Automatic Document Feeder) and to | 
					
						
							|  |  |  | detect double feed errors. | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | .RE | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | Other options will be available based on the capabilities of the scanner. | 
					
						
							| 
									
										
										
										
											2021-02-13 20:02:54 +00:00
										 |  |  | Use | 
					
						
							|  |  |  | .I scanimage \-\-help | 
					
						
							|  |  |  | to get a list, but be aware that some options may | 
					
						
							| 
									
										
										
										
											2017-05-27 05:27:22 +00:00
										 |  |  | be settable only when another option has been set, and that advanced options | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | may be hidden by some frontend programs. | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | .SH CONFIGURATION FILE | 
					
						
							| 
									
										
										
										
											2021-02-02 20:58:54 +00:00
										 |  |  | The configuration file | 
					
						
							|  |  |  | .I kodak.conf | 
					
						
							|  |  |  | is used to tell the backend how to look | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | for scanners, and provide options controlling the operation of the backend. | 
					
						
							| 
									
										
										
										
											2017-05-27 05:27:22 +00:00
										 |  |  | This file is read each time the frontend asks the backend for a list | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | of scanners, generally only when the frontend starts. If the configuration | 
					
						
							|  |  |  | file is missing, the backend will use a set of compiled defaults, which | 
					
						
							|  |  |  | are identical to the default configuration file shipped with SANE. | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | Scanners can be specified in the configuration file in 2 ways: | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | "scsi KODAK" | 
					
						
							|  |  |  | .RS | 
					
						
							| 
									
										
										
										
											2020-08-29 06:33:32 +00:00
										 |  |  | Requests backend to search all scsi buses in the system for a device | 
					
						
							| 
									
										
										
										
											2017-05-27 05:27:22 +00:00
										 |  |  | which reports itself to be a scanner made by 'KODAK'. | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | .RE | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | "scsi /dev/sg0" (or other scsi device file) | 
					
						
							|  |  |  | .RS | 
					
						
							|  |  |  | Requests backend to open the named scsi device. Only useful if you have | 
					
						
							|  |  |  | multiple compatible scanners connected to your system, and need to | 
					
						
							|  |  |  | specify one. Probably should not be used with the other "scsi" line above. | 
					
						
							|  |  |  | .RE | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | The only configuration option supported is "buffer\-size=xxx", allowing you | 
					
						
							| 
									
										
										
										
											2017-05-27 05:27:22 +00:00
										 |  |  | to set the number of bytes in the data buffer to something other than the | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | compiled\-in default, 32768 (32K). Some users report that their scanner will | 
					
						
							|  |  |  | "hang" mid\-page, or fail to transmit the image if the buffer is not large | 
					
						
							|  |  |  | enough. | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | Note: This option may appear multiple times in the configuration file. It only | 
					
						
							|  |  |  | applies to scanners discovered by 'scsi/usb' lines that follow this option. | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | Note: The backend does not place an upper bound on this value, as some users | 
					
						
							|  |  |  | required it to be quite large. Values above the default are not recommended, | 
					
						
							|  |  |  | and may crash your OS or lockup your scsi card driver. You have been | 
					
						
							|  |  |  | warned. | 
					
						
							|  |  |  | .PP | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH ENVIRONMENT | 
					
						
							| 
									
										
										
										
											2021-02-13 20:02:54 +00:00
										 |  |  | The backend uses a single environment variable, | 
					
						
							|  |  |  | .BR SANE_DEBUG_KODAK , | 
					
						
							|  |  |  | which enables debugging output to stderr. Valid values are: | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | .PP | 
					
						
							|  |  |  | .RS | 
					
						
							|  |  |  | 5  Errors | 
					
						
							|  |  |  | .br | 
					
						
							|  |  |  | 10 Function trace | 
					
						
							|  |  |  | .br | 
					
						
							|  |  |  | 15 Function detail | 
					
						
							|  |  |  | .br | 
					
						
							|  |  |  | 20 Option commands | 
					
						
							|  |  |  | .br | 
					
						
							|  |  |  | 25 SCSI trace | 
					
						
							|  |  |  | .br | 
					
						
							|  |  |  | 30 SCSI detail | 
					
						
							|  |  |  | .br | 
					
						
							|  |  |  | 35 Useless noise | 
					
						
							|  |  |  | .RE | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH KNOWN ISSUES | 
					
						
							| 
									
										
										
										
											2017-05-27 05:27:22 +00:00
										 |  |  | Most hardware options are either not supported or not exposed for control by | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | the user, including: multifeed detection, image compression, autocropping, | 
					
						
							| 
									
										
										
										
											2021-08-29 23:00:23 +00:00
										 |  |  | endorser, thresholding, multi\-stream, etc. | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | .PP | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | .SH CREDITS | 
					
						
							| 
									
										
										
										
											2021-02-02 20:58:54 +00:00
										 |  |  | The various authors of the | 
					
						
							|  |  |  | .BR sane\-fujitsu (5) | 
					
						
							|  |  |  | backend provided useful code. | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | .br | 
					
						
							|  |  |  | Kodak provided access to hardware, documentation and personnel. | 
					
						
							| 
									
										
										
										
											2017-05-27 05:27:22 +00:00
										 |  |  | 
 | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | .SH "SEE ALSO" | 
					
						
							| 
									
										
										
										
											2021-02-02 20:58:54 +00:00
										 |  |  | .BR sane (7), | 
					
						
							|  |  |  | .BR sane\-scsi (5), | 
					
						
							|  |  |  | .BR scanimage (1) | 
					
						
							| 
									
										
										
										
											2009-06-23 03:06:22 +00:00
										 |  |  | 
 | 
					
						
							|  |  |  | .SH AUTHOR | 
					
						
							| 
									
										
										
										
											2021-02-13 20:02:54 +00:00
										 |  |  | m. allan noah: | 
					
						
							|  |  |  | .RI < "kitno455 a t gmail d o t com" > |