sane-project-backends/backend/snapscan-sources.h

114 wiersze
4.0 KiB
C
Czysty Zwykły widok Historia

2000-08-12 15:11:46 +00:00
/* sane - Scanner Access Now Easy.
Copyright (C) 1997, 1998 Franck Schnefra, Michel Roelofs,
Emmanuel Blot, Mikko Tyolajarvi, David Mosberger-Tang, Wolfgang Goeller,
Petter Reinholdtsen, Gary Plewa, Sebastien Sable and Kevin Charter
2000-08-12 15:11:46 +00:00
This file is part of the SANE package.
This program is free software; you can redistribute it and/or
modify it under the terms of the GNU General Public License as
published by the Free Software Foundation; either version 2 of the
License, or (at your option) any later version.
This program is distributed in the hope that it will be useful, but
WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
General Public License for more details.
You should have received a copy of the GNU General Public License
along with this program; if not, write to the Free Software
Foundation, Inc., 59 Temple Place - Suite 330, Boston,
MA 02111-1307, USA.
As a special exception, the authors of SANE give permission for
additional uses of the libraries contained in this release of SANE.
The exception is that, if you link a SANE library with other files
to produce an executable, this does not by itself cause the
resulting executable to be covered by the GNU General Public
License. Your use of that executable is in no way restricted on
account of linking the SANE library code into it.
This exception does not, however, invalidate any other reasons why
the executable file might be covered by the GNU General Public
License.
If you submit changes to SANE to the maintainers to be included in
a subsequent release, you agree by submitting the changes that
those changes may be distributed with this exception intact.
If you write modifications of your own for SANE, it is your choice
whether to permit this exception to apply to your modifications.
If you do not wish that, delete this exception notice.
This file is a component of the implementation of a backend for many
of the the AGFA SnapScan and Acer Vuego/Prisa flatbed scanners. */
/* $Id$
SnapScan backend scan data sources */
#ifndef SNAPSCAN_SOURCES_H
#define SNAPSCAN_SOURCES_H
typedef struct source Source;
typedef SANE_Int (*SourceRemaining) (Source *ps);
typedef SANE_Int (*SourceBytesPerLine) (Source *ps);
typedef SANE_Int (*SourcePixelsPerLine) (Source *ps);
typedef SANE_Status (*SourceGet) (Source *ps, SANE_Byte *pbuf, SANE_Int *plen);
typedef SANE_Status (*SourceDone) (Source *ps);
#define SOURCE_GUTS \
2000-08-12 15:11:46 +00:00
SnapScan_Scanner *pss;\
SourceRemaining remaining;\
SourceBytesPerLine bytesPerLine;\
SourcePixelsPerLine pixelsPerLine;\
SourceGet get;\
SourceDone done
2000-08-12 15:11:46 +00:00
struct source
{
SOURCE_GUTS;
};
2000-08-12 15:11:46 +00:00
static SANE_Status Source_init (Source *pself,
SnapScan_Scanner *pss,
SourceRemaining remaining,
SourceBytesPerLine bytesPerLine,
SourcePixelsPerLine pixelsPerLine,
SourceGet get,
SourceDone done);
/* base sources */
#endif
2000-08-12 15:11:46 +00:00
/*
* $Log$
* Revision 1.3 2001/05/26 12:47:31 hmg
* Updated snapscan backend to version 1.2 (from
* Sebastien Sable <Sebastien.Sable@snv.jussieu.fr>).
* Henning Meier-Geinitz <henning@meier-geinitz.de>
*
* Revision 1.3 2001/03/17 22:53:21 sable
* Applying Mikael Magnusson patch concerning Gamma correction
* Support for 1212U_2
*
* Revision 1.1.1.1 2001/02/10 17:09:29 mikael
* Imported from snapscan-11282000.tar.gz
*
* Revision 1.2 2000/10/13 03:50:27 cbagwell
* Updating to source from SANE 1.0.3. Calling this versin 1.1
*
2000-08-12 15:11:46 +00:00
* Revision 1.2 2000/08/12 15:09:35 pere
* Merge devel (v1.0.3) into head branch.
*
* Revision 1.1.2.1 2000/07/13 04:47:46 pere
* New snapscan backend version dated 20000514 from Steve Underwood.
*
* Revision 1.1.1 2000/05/14 13:30:20 coppice
* Added history log to pre-existing code. Some reformatting.
* */