sane-project-backends/doc/sane-mustek_usb.man

193 wiersze
6.1 KiB
Groff
Czysty Zwykły widok Historia

.TH sane-mustek 5 "12 Jan 2002"
.IX sane-mustek_usb
.SH NAME
sane-mustek_usb - SANE backend for Mustek USB flatbed scanners
.SH DESCRIPTION
The
.B sane-mustek_usb
library implements a SANE (Scanner Access Now Easy) backend that
provides access to Mustek (and some relabeled Trust) USB flatbed scanners.
At present, the following scanners are known to work more or less with
this backend:
.PP
.RS
Mustek 600 CU
.br
Mustek 1200 UB
.br
Mustek 1200 CU
.br
Mustek 1200 CU Plus
.br
Trust Compact Scan USB 19200
.br
.RE
.PP
More details can be found on the Mustek backend homepage
.IR http://www.meier-geinitz.de/sane/ .
.PP
The Mustek BearPaw 1200 and 2400 scanners are supported by the plustek
backend. See sane-plustek(5) for details.
.PP
This backend is based on the 1200ub backend provided by Mustek. It was
modified to fit into the SANE distribution, some bugs were fixed, support
for the 600 CU was added, and some features added.
.PP
This is BETA software. It currently only works on Linux and FreeBSD. Other
systems are untested. See BUGS for more information.
.PP
This backend can only work with scanners that are already detected by the
operating system. For Linux, it may be necessary to load the scanner module
with additional vendor/product parameters /see
/usr/src/linux/Documentation/usb/scanner.txt for details). With FreeBSD upto
4.4 only the 1200 CU will work out-of-the box. For other scanners, their ids
must be added to the FreeBSD uscanner.c file and a new kernel must be
compiled.
.PP
If you own a Mustek (or Trust) scanner other than the ones listed above that
works with this backend, please let me know this by sending the scanner's exact
model name and the USB vendor and device ids (e.g. from /proc/bus/usb/devices
or syslog) to me.
.SH "DEVICE NAMES"
This backend expects device names of the form:
.PP
.RS
.I special
.RE
.PP
Where
.I special
is a path-name for the special device that corresponds to a USB scanner.
With Linux, such a device name could be
.I /dev/usb/scanner0
or
.IR /dev/usbscanner1 ,
for example.
.PP
For FreeBSD use
.IR /dev/uscanner0 .
.SH CONFIGURATION
The contents of the
.I mustek_usb.conf
file is a list of options and device names that correspond to Mustek
USB scanners. Empty lines and lines starting with a hash mark (#) are
ignored. If a device name is placed in
.IR mustek_usb.conf ,
it must be followed by a line containing the keyword
.I option
and an option specifying the scanner type. The following options can be used:
.IR 600cu ,
.IR 1200cu ,
.IR 1200cu_plus ,
.IR 1200ub .
For the Trust Compact Scan USB 19200 use `option 1200ub'.
.PP
Instead of using the device name, the scanner can be autodetected by
.I "usb vendor_id product_id"
statements which are already included into
.IR mustek_usb.conf .
This is only supported with Linux 2.4.8 and higher. "vendor_id" and
"product_id" are hexadecimal numbers that identfy the scanner. If this doesn't
work, a device name and the option specifying the scanner type must be placed
in
.IR mustek_usb.conf .
.PP
The global
.I option max_block_size
can be used to limit the amount of data acquired in one turn from the USB
system. It may be woth trying, if USB errors occur.
.PP
A sample configuration file is shown below:
.PP
.RS
# Comment
.br
option max_block_size 1024
.br
usb 0x055f 0x0001
.br
/dev/usb/scanner0
.br
option 600cu
.RE
.PP
The first line is ignored. The second line sets the buffer size to a maximum of
1024 bytes. The third line tries to autodetect a scanner with vendor id 0x055f
and product id 0x0001 (Mustek 1200 CU). The fourth line tells the backend to
attach to /dev/usb/scanner0 and the fifth line specifies that
/dev/usb/scanner0 is a Mustek 600 CU.
.SH FILES
.TP
.I @CONFIGDIR@/mustek_usb.conf
The backend configuration file (see also description of
.B SANE_CONFIG_DIR
below).
.TP
.I @LIBDIR@/libsane-mustek_usb.a
The static library implementing this backend.
.TP
.I @LIBDIR@/libsane-mustek_usb.so
The shared library implementing this backend (present on systems that
support dynamic loading).
.SH ENVIRONMENT
.TP
.B SANE_CONFIG_DIR
This environment variable specifies the list of directories that may
contain the configuration file. Under UNIX, the directories are
separated by a colon (`:'), under OS/2, they are separated by a
semi-colon (`;'). If this variable is not set, the configuration file
is searched in two default directories: first, the current working
directory (".") and then in @CONFIGDIR@. If the value of the
environment variable ends with the directory separator character, then
the default directories are searched after the explicitly specified
directories. For example, setting
.B SANE_CONFIG_DIR
to "/tmp/config:" would result in directories "tmp/config", ".", and
"@CONFIGDIR@" being searched (in this order).
.TP
.B SANE_DEBUG_MUSTEK_USB
If the library was compiled with debug support enabled, this
environment variable controls the debug level for this backend. Higher
debug levels increase the verbosity of the output.
.nf
Value Descsription
0 no output
1 print fatal errors
2 print important messages
3 print non-fatal errors and less important messages
4 print all but debugging messages
5 print high level debugging messages
6 print medium level debugging messages
7 print low level debugging messages
Example:
export SANE_DEBUG_MUSTEK_USB=4
.SH "SEE ALSO"
sane(7), sane-usb(5), sane\-mustek(5), sane\-mustek_pp(5), sane-plustek(5)
.br
@DOCDIR@/mustek_usb/mustek_usb.CHANGES,
@DOCDIR@/mustek_usb/mustek_usb.TODO
.SH AUTHOR
Tom Wang (Mustek, original 1200ub backend), Henning Meier-Geinitz
<henning@meier-geinitz.de>
.SH BUGS
This is BETA software. That means that it may contain bugs.
.PP
FreeBSD support is shaky. Most of the time, scanning will work only in the
first xscanimage/xsane session. After closing the frontend, the scanner will
freeze. The reason is unknown until now.
.PP
More detailed bug information is
available at the Mustek backend homepage
.IR http://www.meier-geinitz.de/sane/ .
See also the CHANGES and TODO files.
Please contact me if you find a bug or missing feature:
<henning@meier-geinitz.de>