											2002-12-08 21:00:31 +00:00
										 |  |  | gt68xx.CHANGES -*-text-*- | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2003-02-22 15:34:51 +00:00
										 |  |  | V 1.0-40 (2003-02-22) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Added vid/pid 0x07b3/0x0400 to gt68xx.conf also | 
					
						
							|  |  |  | - Added indormation about Medion 4394. | 
					
						
							|  |  |  | - Mention ma1509 backend. | 
					
						
							|  |  |  | - Fix segfault when calling sane_open with an empty device name. | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2003-02-16 21:31:45 +00:00
										 |  |  | V 1.0-39 (2003-02-16) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Added BearPaw 2400 CS Plus as supported. | 
					
						
							|  |  |  | - Make fast preview the default (otherwise BP 2400 TA Plus wouldn't work with | 
					
						
							|  |  |  |   12/16 bits). | 
					
						
							|  |  |  | - Added vid/pid 0x07b3/0x0400, that's another Plustek OpticPro 1248U. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2003-02-05 16:02:45 +00:00
										 |  |  | V 1.0-38 (2003-02-05) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Fixed resolutions for BearPaw 1200 TA (75 instead of 100). | 
					
						
							|  |  |  | - Increase the lowest black for CCD coarse calibration to avoid too much black. | 
					
						
							|  |  |  | - Adjusted internal gamma correction to avoid getting 0 for high gamma values. | 
					
						
							|  |  |  | - CCD scanners use color mode for coarse+quality cal now. This fixes the | 
					
						
							|  |  |  |   problem with extremly high gains and terrible quality cal in gray mode at | 
					
						
							|  |  |  |   least for the BearPaw 1200 TA. | 
					
						
							|  |  |  | --> Thanks to Alexei V. Mezin for reporting these bugs. | 
					
						
							|  |  |  | - Preview isn't always in 8 bit mode now (can be selected by option). | 
					
						
							|  |  |  | - Upper and lower limits for coarse calibration are unified now. | 
					
						
							|  |  |  | - Added options for adjusting gain and offset. | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2003-01-18 11:46:15 +00:00
										 |  |  | V 1.0-37 (2003-01-18) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Removed untested flag from A3 USB and Lexmark X70/X73. | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2003-01-09 18:05:01 +00:00
										 |  |  | V 1.0-36 (2003-01-09) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Updated manpage and .desc concerning Lexmark X70. | 
					
						
							|  |  |  | - Updated manpage concerning kernel 2.4.21-pre3 containing the 1-endpoint fix. | 
					
						
							|  |  |  | - Fixed A3 USB resolution setting. | 
					
						
							|  |  |  | - Updated A3 USB margins (Pedro Morais <morais@inocam.com>). | 
					
						
							|  |  |  | - Added detection of Genius Colorpage Vivid3x. It's unknown if it works. | 
					
						
							|  |  |  | - Updated .desc file. | 
					
						
							|  |  |  | - Don't print calib line warnings by default. | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2002-12-30 13:05:24 +00:00
										 |  |  | V 1.0-35 (2002-12-23) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Added "afe" option for gt68xx.conf for selecting default afe values. | 
					
						
							|  |  |  | - Removed AFE and exposure SANE options. | 
					
						
							|  |  |  | - Added documentation for afe option in gt68xx.conf. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-34 (2002-12-18) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - fixed gt68xx_gt6801 -> lamp control. | 
					
						
							|  |  |  | - adjusted Plustek 1248U geometry and afe values. | 
					
						
							|  |  |  | - CCD gross calibration changed: start with the default value from module struct. | 
					
						
							|  |  |  |   Is faster now for most cases. | 
					
						
							|  |  |  | - Only 2.5 mm of calibration for GT-6801 scanners. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-33 (2002-12-10) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Updated ScanExpress 2400 USB values (from "Fan Dan" <dan_fancn@hotmail.com>). | 
					
						
							|  |  |  | - Added implementation of gt6801 lamp control for CCD scanners. | 
					
						
							|  |  |  | - Added flag for SE 2400 USB, added some quirks in gt68xx_gt6801.c. | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2002-12-08 21:00:31 +00:00
										 |  |  | V 1.0-32 (2002-12-08) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - "Coarse calibration for first scan only" is off by default now. As at least | 
					
						
							|  |  |  |   CIS calibration is faster now, it doesn't seem to be necessary and produces | 
					
						
							|  |  |  |   wrong images sometimes. | 
					
						
							|  |  |  | - Added gamma table. | 
					
						
							|  |  |  | - Setup gamma to 2.0 by default. | 
					
						
							|  |  |  | - Fixed (hopefully) sigpipe when cancelling. | 
					
						
							|  |  |  | - No geometry quantization anymore (not necessary). That should fix scanimage | 
					
						
							|  |  |  |   warnings. | 
					
						
							|  |  |  | - Plustek 1248U: do linemode for every resolution, fix color correction. | 
					
						
							|  |  |  | - Set SANE_CAP_EMULATED for gamma value. | 
					
						
							|  |  |  | - Added comments for every Model member in gt68xx_devices. | 
					
						
							|  |  |  | - Added Plustek UT16B and Genius Vivid3x to .desc. | 
					
						
							|  |  |  | - Added implementation for inverted offset for CCD scanners. | 
					
						
							|  |  |  | - Added Mustek ScanExpress 2400 USB. Well, at least it's detected. | 
					
						
							|  |  |  | - Added NEW marker to .desc. | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2002-11-21 22:09:16 +00:00
										 |  |  | V 1.0-31 (2002-11-21) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Changed 150 to 200 dpi for Mustek BearPaw 2400 TA. | 
					
						
							|  |  |  | - Fixed warnings in gt68xx_low.c | 
					
						
							| 
									
										
										
										
											2002-12-30 13:05:24 +00:00
										 |  |  | - Used DBG instead of XDBG in gt68xx_low.c | 
					
						
							| 
									
										
										
										
											2002-11-21 22:09:16 +00:00
										 |  |  | - Minor manpage fixes. Added man page links to other backends. | 
					
						
							|  |  |  | - gt68xx_low.h: Fixed __FUNCTION__ bug on non-gcc compilers. | 
					
						
							|  |  |  | - Added more details about the BSDs in the manpage. | 
					
						
							|  |  |  | - Fixed color order for ScanExpress A3 USB. | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2002-11-13 17:45:24 +00:00
										 |  |  | V 1.0-30 (2002-11-13) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Added basic support for Plustek OpticPro 1248U (from Gerhard Jaeger | 
					
						
							|  |  |  |   <gerhard@gjaeger.de>). Only gray mode without calib seems to work until | 
					
						
							|  |  |  |    now. | 
					
						
							|  |  |  | - Removed 50 and 1200 dpi from Lexmark X73 (doesn't seem to work). Decreased | 
					
						
							|  |  |  |   height. | 
					
						
							|  |  |  | - Backend status is BETA now. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-29 (2002-11-07) | 
					
						
							| 
									
										
										
										
											2002-11-07 12:50:19 +00:00
										 |  |  | 
 | 
					
						
							|  |  |  | - Changed option titles and descriptions to make them better readable. | 
					
						
							|  |  |  | - Added translation markers for all options. | 
					
						
							|  |  |  | - Added German translation for backend options. | 
					
						
							|  |  |  | - Updated manpage and .desc file concerning scanner status. | 
					
						
							|  |  |  | - Added untested flag for Mustek ScanEpress A3 USB and Lexmark X73. | 
					
						
							|  |  |  | 
 | 
					
						
							| 
									
										
										
										
											2002-10-31 19:50:44 +00:00
										 |  |  | V 1.0-28 (2002-10-31) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Reduce scan width of 2400 TA Plus: otherwise the black mark would create | 
					
						
							|  |  |  |   light vertical stripes. | 
					
						
							|  |  |  | - Removed default parameters. Set AFE and exposure in every model struct. | 
					
						
							|  |  |  | - Faster automatic gain setting for the CIS scanners. The default values from | 
					
						
							|  |  |  |   the model struct and the last values are used for calculation. | 
					
						
							|  |  |  | - Set default AFE values for ScanExpress 1200 UB Plus, BearPaw 1200 CU, BearPaw | 
					
						
							|  |  |  |   2400 CU Plus. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-27 (2002-10-25) | 
					
						
							| 
									
										
										
										
											2002-10-25 12:22:32 +00:00
										 |  |  | 
 | 
					
						
							|  |  |  | - Bugfix: override applies to all devices found by the last usb line. | 
					
						
							|  |  |  | - Individual resolutions + depth values for every scanner. | 
					
						
							|  |  |  | - Bugfix: Mirroring code had an off-by-one error (garbage in the first column). | 
					
						
							|  |  |  | - Artec Ultima 2000, MD 9385: Removed 1200 dpi mode (doesn't seem to work?), | 
					
						
							|  |  |  |   added 100 and 200 dpi modes. Renamed model to Artec Ultima 2000, because | 
					
						
							|  |  |  |   that's probably the "father" of all the clones. | 
					
						
							|  |  |  | - Mustek BearPaw 1200 CU: Added 200 dpi mode. | 
					
						
							|  |  |  | - Added manual page. | 
					
						
							|  |  |  | - Removed override for Packard Bell (seems to be exact Bearpaw 1200 CU Plus | 
					
						
							|  |  |  |   clone). | 
					
						
							|  |  |  | - Removed override for Trust Copmact Scan and Medion/Tevion/Lifetec LT 9452 | 
					
						
							|  |  |  |   (Mustek ScanExpress 1200 UB Plus clones). | 
					
						
							|  |  |  | - Removed override for Tevion MD 9458 (seems to be an Artec Ultima 2000 (e +?) | 
					
						
							|  |  |  |   clone).  | 
					
						
							|  |  |  |    | 
					
						
							|  |  |  | V 1.0-26 (2002-10-22) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Several fixes for Medion MD-9385 and Artec Ultima 2000 based scanners. The | 
					
						
							|  |  |  |   Cytron MD 9385 works now. | 
					
						
							|  |  |  | - Diabled Plustek-like firmware check again, didn't work for MD 9385. | 
					
						
							|  |  |  | - Splitted flags for mirror_x and sset_home. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-25 (2002-10-20) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Fixed segfault for GT-6801 based scanners. | 
					
						
							|  |  |  | - Added override for Medion MD9385. | 
					
						
							|  |  |  | - Changed firmware detection code for Plustek scanners. | 
					
						
							|  |  |  | - CIS autogain seraches max white and min black now (removed segment code). | 
					
						
							|  |  |  |   Hopefully no more vertical stripes. | 
					
						
							|  |  |  | - Adjusted ScanExpress 1200 UB Plus and BearPaw 1200 CU geometry and white | 
					
						
							|  |  |  |   strip. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-24 (2002-10-12) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Added "override" keyword for gt68xx.conf. So model settings can be changed | 
					
						
							|  |  |  |   at run-time. If set up correctly, firmware lines aren't necessary any more. | 
					
						
							|  |  |  | - Added support for the Mustek BearPaw 2400 CU. | 
					
						
							|  |  |  | - Tevion hack (now enabled by override option) also mirrors coordinates. | 
					
						
							|  |  |  | - Mustek BearPaw 1200 TA 1200 dpi is set up for the Windows firmware again. | 
					
						
							|  |  |  | - Added some basic I18N markers. | 
					
						
							|  |  |  | - Removed option backtrack (setup automatically now). | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-23 (2002-10-10), | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Added detection of Mustek BearPaw A3 USB. | 
					
						
							|  |  |  | - Added auto-detection of lamp status for CCD scanners (from David Stevenson). | 
					
						
							|  |  |  |   No wait for the fixed time of 40 seconds any more. | 
					
						
							|  |  |  | - The scan slider of the GT-6816 bsed scanners don't move home after | 
					
						
							|  |  |  |   calibration/gain. TA mode is faster therefore. | 
					
						
							|  |  |  | - Added hack for Tevion MD 9458 to solve the mirror and "scan-slider doesn't | 
					
						
							|  |  |  |   come home" problems. | 
					
						
							|  |  |  | - Fixed BearPaw 1200 TA 1200 dpi problem. | 
					
						
							|  |  |  | - Fixed manual firmware selection in gt68xx.conf. | 
					
						
							|  |  |  | - Added warning if power supply isn't ok. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-22 (2002-10-07), | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Mustek Bearpaw 2400 CU Plus works in gray mode again | 
					
						
							|  |  |  | - Line calibration uses the bit depth of the main scan now. | 
					
						
							|  |  |  | - Vendor, product ids and other information is printed when debugging is active | 
					
						
							|  |  |  | - Fixed segfault in attach (). | 
					
						
							|  |  |  | - Fixed endianess issues (untested). | 
					
						
							|  |  |  | - Code cleanup. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-21 (2002-10-07), | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Added 12 bit modes for all scanners (Sergey Vlasov). | 
					
						
							|  |  |  | - Fixed 2400 TA Plus in 12/16 bit modes in 1200/2400 dpi. | 
					
						
							|  |  |  | - Disable depth option in lineart mode and for some scanners in gray mode. | 
					
						
							|  |  |  | - Scan preview in 8 bit. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-20 (2002-10-06) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Calibration of the CCD scanners in gray mode should work better now. | 
					
						
							|  |  |  | - Added 50 dpi mode for BearPaw 2400 TA Plus. Faster preview. | 
					
						
							|  |  |  | - By default, /usr/local/share/sane/gt68xx/ is checked for firmware files. | 
					
						
							|  |  |  |   Manual adjustment is only necessary if the firmware name is different from | 
					
						
							|  |  |  |   default or at a different path. | 
					
						
							|  |  |  | - Mixed and lower-case is tried when loading the firmware. | 
					
						
							|  |  |  | - Adjusted geometry of BearPaw 1200 TA and 2400 TA. | 
					
						
							|  |  |  | - Automatic gain fixes for TA mode. | 
					
						
							|  |  |  | - Don't show "lamp off" option for CIS scanners. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-19 (2002-10-01) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Various minor fixes and adjustments concerning calibration. | 
					
						
							|  |  |  | - Fixed sane_open detection of already known devices. | 
					
						
							|  |  |  | - Added missing usleep for 2400 CU Plus. | 
					
						
							|  |  |  | - Adjusted scan area for 1200 TA. | 
					
						
							|  |  |  | - Removed detection of Artec Umltima 2000 (product id 0x4001) as this is not | 
					
						
							|  |  |  |   a GT-68xx based scanner. | 
					
						
							|  |  |  | - Fixed some compilation warnings. | 
					
						
							|  |  |  | - Minor misc fixes. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-18 (2002-10-01) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Added detection of Artec Ultima 2000. | 
					
						
							|  |  |  | - Updated Lexmark X70 settings. | 
					
						
							|  |  |  | - Fixed segfault that occured when no device was detected. | 
					
						
							|  |  |  | - Changed test for loaded firmware for GT-6801 scanners. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-17 (2002-10-01) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Added support for the Lexmark X70 and X73 scanners | 
					
						
							|  |  |  | - Fixed shifted columns problem for BearPaw 2400 TA Plus and maybe 2400 TA. | 
					
						
							|  |  |  | - Fixed y-margin for the BearPaw 1200 TA (at least I hope so) | 
					
						
							|  |  |  | - Fixed BearPaw 2400 CU Plus firmware name | 
					
						
							|  |  |  | - Removed gt68xx_test program from distribution. Didn't work anymore anyway. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-16 (2002-09-29) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Added calibration and auto-gain support for transparency adapter mode. | 
					
						
							|  |  |  | - In transparency adapter mode, only the usable scan area is shown. | 
					
						
							|  |  |  | - Autogain is repeated when source was change.d | 
					
						
							|  |  |  | - Fixed geometry of ScanExpress 1200 UB Plus. | 
					
						
							|  |  |  | - Fixed freeze at the end of scan for GT-6801-based scanners. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-15 (2002-09-27) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Low level reading is done in a separate process now (shm is back). Some | 
					
						
							|  |  |  |   scanners should be faster therefore. | 
					
						
							|  |  |  | - Added option "force backtracking". If disabled, no backtracking occurs | 
					
						
							|  |  |  |   (->faster, but lines are lost). | 
					
						
							|  |  |  | - Fixed hang in reader_process. | 
					
						
							|  |  |  | - Fixed "auto gain once" (which really worked only once :-/) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-14 (2002-09-25) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Added basic transaprency adapter support for the Mustek Bearpaw 2400 TA | 
					
						
							|  |  |  |   Plus. Other TA models may work also. No calibration or other nice features, | 
					
						
							|  |  |  |   just pure external lamp on, internal lamp of. | 
					
						
							|  |  |  | - Support for the Mustek BearPaw 1200 Cu Plus (hopefully). | 
					
						
							|  |  |  | - Added Lineart (black/white) mode. | 
					
						
							|  |  |  | - Added warming-up for CCD lamps and an option to disable shutting off the | 
					
						
							|  |  |  |   lamp. | 
					
						
							|  |  |  | - Print scanning time (debug level 3). | 
					
						
							|  |  |  | - Removed "safe preview". Not longer necessary. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-13 (2002-09-25) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Major rewrite of the low level scan setup functions. Probably has broken | 
					
						
							|  |  |  |   some of the supported scanners. | 
					
						
							|  |  |  | - Geometry in the model struct is in mm now. Values for most scanners are | 
					
						
							|  |  |  |   untested. | 
					
						
							|  |  |  | - Added support for Mustek Bearpaw 2400 CU Plus. | 
					
						
							|  |  |  | - CCD lamp is turned on when opening the frontend and turned off when leaving. | 
					
						
							|  |  |  | - Auto gain is done only for the first scan. | 
					
						
							|  |  |  | - Manual gain etc. options don't show up in automatic mode. | 
					
						
							|  |  |  | - Faster automatic gain. | 
					
						
							|  |  |  | - Bugfixes: gain/offset options, moving top-margin and exposure control. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-12 (2002-09-23) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Fixed bug concerning too little data transferred in sane_read. | 
					
						
							|  |  |  | - Added detection of the Packard Bell Diamond 1200. | 
					
						
							|  |  |  | - Changed some scanner names and added support for custom names in config file. | 
					
						
							|  |  |  | - Use the size of the scan area in the model struct. This value may need | 
					
						
							|  |  |  |   some tweaking for the gt6816 scanners. | 
					
						
							|  |  |  | - Fixed the size of scanarea for the BearPaw 1200 CU/ScanEpress 1200 UB Plus | 
					
						
							|  |  |  | - Disabled 16 bit mode for GT-6801 scanners. This isn't even supported by the | 
					
						
							|  |  |  |   Windows driver. | 
					
						
							|  |  |  | - General code cleanup. Removed gt68xx_mustek.c and SHM support. | 
					
						
							|  |  |  | - Made the .tar.gz file size smaller. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-11 (2002-09-22) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - 1200 dpi works now at least for the BearPaw 1200 CU. Maybe also for the | 
					
						
							|  |  |  |   other scanners. | 
					
						
							|  |  |  | - Added manual and automatic offset/gain/exposure control for the CIS | 
					
						
							|  |  |  |   scanners. The image should be better now. | 
					
						
							|  |  |  | - Added debug option to scan the full scan area including the calibration | 
					
						
							|  |  |  |   strip. | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-10 (2002-09-18) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - 50, 75, 150, 300, 600 work now for the GT6801 scanners | 
					
						
							|  |  |  | - Preview is fast again (can be set to safe/slow mode) | 
					
						
							|  |  |  | - Calibration can be disabled by option | 
					
						
							|  |  |  | - Added some more safety checks for USB commands | 
					
						
							|  |  |  | - The gt68xx_test program can be used again | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-9 (2002-09-17) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Added option to disable automatic gain (->less ugly colors for GT-6801 | 
					
						
							|  |  |  |   based models) | 
					
						
							|  |  |  | - Fixed segfault that occured when a scan was cancelled | 
					
						
							|  |  |  | - Preview uses slow but safe (?) 300 dpi 8 bit modes now | 
					
						
							|  |  |  | - Fixed bug concerning X0/Y0 coordinates | 
					
						
							|  |  |  | - Started implementing dpeth option (doesn't work yet) | 
					
						
							|  |  |  | - Internal changes (use high_scan's wait_for_positioning) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-8 (2002-09-16) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Fixed distortion problem in color mode | 
					
						
							|  |  |  | - Selected safer default option values | 
					
						
							|  |  |  | - Changed file names to be more appropriate for SANE | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | V 1.0-7 (2002-09-16) | 
					
						
							|  |  |  | 
 | 
					
						
							|  |  |  | - Initial version based on Sergey Vlasov's gt68xx backend v 0.0.6 | 
					
						
							|  |  |  | - Added basic SANE interface in gt68xx.c | 
					
						
							|  |  |  | - Added SANE options and SANE variables to gt68xx_high.h | 
					
						
							|  |  |  | - Minor adjustments to gt68xx_low.h | 
					
						
							|  |  |  | - Added support for Mustek BearPaw 2400 TA Plus |