@ -430,17 +430,36 @@ def clean_task_list():
|
|||
autorx.task_list["SCAN"]["task"].add_temporary_block(_key)
|
||||
|
||||
if _exit_state == "FAILED SDR":
|
||||
# The SDR was not able to be recovered after many attempts.
|
||||
# Remove it from the SDR list and flag an error.
|
||||
autorx.sdr_list.pop(_task_sdr)
|
||||
_error_msg = (
|
||||
"Task Manager - Removed SDR %s from SDR list due to repeated failures."
|
||||
% (str(_task_sdr))
|
||||
)
|
||||
logging.error(_error_msg)
|
||||
# The SDR was not able to be recovered after many (usually 5) attempts.
|
||||
|
||||
if config["sdr_type"] == "RTLSDR":
|
||||
# If we are using RTLSDRs, then if we're at this point there's nothing more we can do
|
||||
# to recover them, so we remove it from our SDR list.
|
||||
autorx.sdr_list.pop(_task_sdr)
|
||||
_error_msg = (
|
||||
"Task Manager - Removed SDR %s from SDR list due to repeated failures."
|
||||
% (str(_task_sdr))
|
||||
)
|
||||
|
||||
logging.error(_error_msg)
|
||||
|
||||
# Send email if configured.
|
||||
email_error(_error_msg)
|
||||
|
||||
else:
|
||||
# If we're using either KA9Q-Radio or a Spyserver, then we shouldn't remove the 'pseudo'-SDR
|
||||
# entries from our list, and instead wait for the server to come back.
|
||||
_error_msg = f"Task Manager - Ongoing issue with {config['sdr_type']} server connection ({str(_task_sdr)}). Please check the logs."
|
||||
logging.error(_error_msg)
|
||||
# Don't send an email for this one yet... need to think about error email rate limiting.
|
||||
|
||||
# Shutdown the SDR, if required for the particular SDR type.
|
||||
if _key != 'SCAN':
|
||||
shutdown_sdr(config["sdr_type"], _task_sdr, sdr_hostname=config["sdr_hostname"], frequency=_key)
|
||||
# Release its associated SDR.
|
||||
autorx.sdr_list[_task_sdr]["in_use"] = False
|
||||
autorx.sdr_list[_task_sdr]["task"] = None
|
||||
|
||||
# Send email if configured.
|
||||
email_error(_error_msg)
|
||||
|
||||
else:
|
||||
# Shutdown the SDR, if required for the particular SDR type.
|
||||
|
|
|
|||
|
|
@ -12,7 +12,7 @@ from queue import Queue
|
|||
# MINOR - New sonde type support, other fairly big changes that may result in telemetry or config file incompatability issus.
|
||||
# PATCH - Small changes, or minor feature additions.
|
||||
|
||||
__version__ = "1.8.2-beta2"
|
||||
__version__ = "1.8.2-beta3"
|
||||
|
||||
# Global Variables
|
||||
|
||||
|
|
|
|||
|
|
@ -840,7 +840,7 @@ class SondeScanner(object):
|
|||
# If we have hit the maximum number of permissable errors, quit.
|
||||
if self.error_retries > self.SONDE_SCANNER_MAX_ERRORS:
|
||||
self.log_error(
|
||||
"Exceeded maximum number of consecutive RTLSDR errors. Closing scan thread."
|
||||
"Exceeded maximum number of consecutive SDR errors. Closing scan thread."
|
||||
)
|
||||
break
|
||||
|
||||
|
|
|
|||