c05268a5b4 | ||
---|---|---|
.github | ||
.idea | ||
NanoVNASaver | ||
test | ||
.coveragerc | ||
.gitignore | ||
.pylintrc | ||
CHANGELOG.md | ||
LICENSE | ||
Pipfile | ||
README.md | ||
_config.yml | ||
icon_48x48.png | ||
nanovna-saver.py | ||
requirements.txt | ||
setup.cfg | ||
setup.py |
README.md
NanoVNASaver
A multiplatform tool to save Touchstone files from the NanoVNA, sweep frequency spans in segments to gain more than 101 data points, and generally display and analyze the resulting data.
- Copyright 2019, 2020 Rune B. Broberg
- Copyright 2020 NanoVNA-Saver Authors
Latest Changes
Changes in v0.3.6
- Added bandwidth setting in device manage dialog
Changes in v0.3.5
- Sweep worker now initializes full dataset on setting changes. Therefore no resize of charts when doing multi segment sweep
- Changing datapoints in DeviceSettings are reflected in SweepSettings widget step size
- Simplified calibration code by just using scipy.interp1d with fill_value
- Established Interface class to ease locking and allow non usb connections in future
- Cleaned up VNA code. Added some pause statements to get more robust readings
- Added MagLoopAnalysis
- Touchstone class can now generate interpolated Datapoints for a given frequency Will be usefull in future analysis code
- Fixed a bug in Version comparison
Changes in v0.3.4
- Refactored Analysis
- Add Antenna Analysis
- Fixed bug in Through Calibration
- Fixed bug in s2p saving
- Fixed crash when clicking connect with no device connected
- Fixed module error with source installation if pkg_resources missing
Changes in v0.3.3
- Fixed data acquisition with S-A-A-2 / NanoVNA V2
- Refactored calibration code
- Calibration data between known datapoints is now interpolated using spline interpolation
- Fixed Through Calibration (CH0 -> CH1)
Changes in v0.3.2
- This adds support for the SAA2, a VNA loosely based on the original NanoVNA with frequency range up to 3GHz.
- Added ability to add use an attenuator and add the Antenuation in s11 sweep settings for amplifier measurements.
Introduction
This software connects to a NanoVNA and extracts the data for display on a computer and allows saving the sweep data to Touchstone files.
Current features:
- Reading data from a NanoVNA -- Compatible devices: NanoVNA, NanoVNA-H, NanoVNA-H4, NanoVNA-F, AVNA via Teensy
- Splitting a frequency range into multiple segments to increase resolution (tried up to >10k points)
- Averaging data for better results particularly at higher frequencies
- Displaying data on multiple chart types, such as Smith, LogMag, Phase and VSWR-charts, for both S11 and S21
- Displaying markers, and the impedance, VSWR, Q, equivalent capacitance/inductance etc. at these locations
- Displaying customizable frequency bands as reference, for example amateur radio bands
- Exporting and importing 1-port and 2-port Touchstone files
- TDR function (measurement of cable length) - including impedance display
- Filter analysis functions for low-pass, high-pass, band-pass and band-stop filters
- Display of both an active and a reference trace
- Live updates of data from the NanoVNA, including for multi-segment sweeps
- In-application calibration, including compensation for non-ideal calibration standards
- Customizable display options, including "dark mode"
- Exporting images of plotted values
Running the application
The software was written in Python on Windows, using Pycharm, and the modules PyQT5, numpy, scipy and pyserial.
Binary releases
You can find 64bit binary releases for Windows, Linux and MacOS under https://github.com/NanoVNA-Saver/nanovna-saver/releases/
Windows
Versions older than Windows 7 are not known to work.
Windows 7
It requires Service Pack 1 and [Microsoft VC++ Redistributable] (https://support.microsoft.com/en-us/help/2977003/the-latest-supported-visual-c-downloads). For most users, this would already be installed.
Windows 10
The downloadable executable runs directly, and requires no installation.
Installation and Use with pip
-
Clone repo and cd into the directory
git clone https://github.com/NanoVNA-Saver/nanovna-saver cd nanovna-saver
-
Run the pip installation
pip3 install .
-
Once completed run with the following command
NanoVNASaver
Linux
Ubuntu 18.04 & 19.04
Installation and Use with pip
-
Install python3.7 and pip
sudo apt install python3.7 python3-pip
-
Clone repo and cd into the directory
git clone https://github.com/NanoVNA-Saver/nanovna-saver cd nanovna-saver
-
Update pip and run the pip installation
python3.7 -m pip install -U pip python3.7 -m pip install .
(You may need to install the additional packages python3-distutils, python3-setuptools and python3-wheel for this command to work on some distributions.)
-
Once completed run with the following command
python3.7 nanovna-saver.py
Mac OS:
MacPorts
Via a MacPorts distribution maintained by @ra1nb0w.
-
Install MacPorts following the install guide
-
Install NanoVNASaver :
sudo port install NanoVNASaver
-
Now you can run the software from shell
NanoVNASaver
or run as app/Applications/MacPorts/NanoVNASaver.app
Homebrew
-
Install Homebrew From : https://brew.sh/
/usr/bin/ruby -e "$(curl -fsSL https://raw.githubusercontent.com/Homebrew/install/master/install)"
-
Python :
brew install python
-
NanoVNASaver Installation
git clone git clone https://github.com/NanoVNA-Saver/nanovna-saver cd nanovna-saver
-
Install local pip packages
python3 -m pip install . NanoVNASaver
Using the software
Connect your NanoVNA to a serial port, and enter this serial port in the serial port box. If the NanoVNA is connected before the application starts, it should be automatically detected. Otherwise, click "Rescan". Click "Connect to device" to connect.
The app can collect multiple segments to get more accurate measurements. Enter the number of segments to be done in the "Segments" box. Each segment is 101 data points, and takes about 1.5 seconds to complete.
Frequencies are entered in Hz, or suffixed with k or M. Scientific notation (6.5e6 for 6.5MHz) also works.
Markers can be manually entered, or controlled using the mouse. For mouse control, select the active marker using the radio buttons, or hold "shift" while clicking to drag the nearest marker. The marker readout boxes show the actual frequency where values are measured. Marker readouts can be hidden using the "hide data" button when not needed.
Display settings are available under "Display setup". These allow changing the chart colours, the application font size and which graphs are displayed. The settings are saved between program starts.
Calibration
Before using NanoVNA-Saver, please ensure that the device itself is in a reasonable calibration state. A calibration of both ports across the entire frequency span, saved to save slot 0, is sufficient. If the NanoVNA is completely uncalibrated, its readings may be outside the range accepted by the application.
In-application calibration is available, either assuming ideal standards or with relevant standard correction. To manually calibrate, sweep each standard in turn and press the relevant button in the calibration window. For assisted calibration, press the "Calibration Assistant" button. If desired, enter a note in the provided field describing the conditions under which the calibration was performed.
Calibration results may be saved and loaded using the provided buttons at the bottom of the window. Notes are saved and loaded along with the calibration data.
Users of known characterized calibration standard sets can enter the data for these, and save the sets.
After pressing Apply, the calibration is immediately applied to the latest sweep data.
Currently, load capacitance is unsupported
TDR
To get accurate TDR measurements, calibrate the device, and attach the cable to be measured at the calibration plane - i.e. at the same position where the calibration load would be attached. Open the "Time Domain Reflectometry" window, and select the correct cable type, or manually enter a propagation factor.
Frequency bands
Open the "Display setup" window to configure the display of frequency bands. By clicking "show bands", predefined frequency bands will be shown on the frequency-based charts. Click manage bands to change which bands are shown, and the frequency limits of each. Bands default and reset to European amateur radio band frequencies.
License
This software is licensed under version 3 of the GNU General Public License. It comes with NO WARRANTY.
You can use it, commercially as well. You may make changes to the code, but I (and the license) ask that you give these changes back to the community.
Links
- Ohan Smit wrote an introduction to using the application: [https://zs1sci.com/blog/nanovnasaver/]
- HexAndFlex wrote a 3-part (thus far) series on Getting Started with the NanoVNA: [https://hexandflex.com/2019/08/31/getting-started-with-the-nanovna-part-1/] - Part 3 is dedicated to NanoVNASaver: [https://hexandflex.com/2019/09/15/getting-started-with-the-nanovna-part-3-pc-software/]
- Gunthard Kraus did documentation in English and German: [http://www.gunthard-kraus.de/fertig_NanoVNA/English/] [http://www.gunthard-kraus.de/fertig_NanoVNA/Deutsch/]
Credits
Original application by Rune B. Broberg (5Q5R)
Contributions and changes by Holger Müller, David Hunt and others.
TDR inspiration shamelessly stolen from the work of Salil (VU2CWA) at https://nuclearrambo.com/wordpress/accurately-measuring-cable-length-with-nanovna/
TDR cable types by Larry Goga.
Bugfixes and Python installation work by Ohan Smit.
Thanks to everyone who have tested, commented and inspired. Particular thanks go to the alpha testing crew who suffer the early instability of new versions.
This software is available free of charge. If you read all this way, and you still want to support it, you may donate to the developer using the button below: