kopia lustrzana https://github.com/NanoVNA-Saver/nanovna-saver
Merge pull request #7 from MZachmann/speedup_scan
speed up sweep by not resetting limits on end of sweeppull/193/head
commit
befcc32db7
|
@ -96,7 +96,7 @@ class SweepWorker(QtCore.QRunnable):
|
|||
return
|
||||
|
||||
span = sweep_to - sweep_from
|
||||
stepsize = int(span / (self.vna.datapoints-1 + (self.noSweeps-1)*self.vna.datapoints))
|
||||
stepsize = int(span / (self.noSweeps * self.vna.datapoints - 1))
|
||||
|
||||
# Setup complete
|
||||
|
||||
|
@ -172,7 +172,8 @@ class SweepWorker(QtCore.QRunnable):
|
|||
self.running = False
|
||||
self.signals.sweepFatalError.emit()
|
||||
|
||||
# Reset the device to show the full range
|
||||
# Reset the device to show the full range if we were multisegment
|
||||
if self.noSweeps > 1 :
|
||||
logger.debug("Resetting NanoVNA sweep to full range: %d to %d",
|
||||
RFTools.parseFrequency(self.app.sweepStartInput.text()),
|
||||
RFTools.parseFrequency(self.app.sweepEndInput.text()))
|
||||
|
|
Ładowanie…
Reference in New Issue