NanoVNASaver
============
A multiplatform tool to save Touchstone files from the NanoVNA, sweep frequency spans in segments to gain more than
101 data points, and generally display and analyze the resulting data.
NanoVNASaver ============ A multiplatform tool to save Touchstone files from
the NanoVNA, sweep frequency spans in segments to gain more than 101 data
points, and generally display and analyze the resulting data.
Copyright 2019, 2020 Rune B. Broberg
## Changes in this fork
This fork adds support for the saa2, a vna loosely based on the original nanovna with frequency range up to 3Ghz.
## Changes in this fork
- This fork adds support for the saa2, a vna loosely
based on the original nanovna with frequency range up to 3Ghz.
- Added ability to add attenutor values in s11 sweep settings
for amplifier measuremnts
## Introduction
This software connects to a NanoVNA and extracts the data for display on a computer, and for saving to Touchstone files.
## Introduction This software connects to a NanoVNA and extracts the data for
display on a computer, and for saving to Touchstone files.
Current features:
- Reading data from a NanoVNA
-- Compatible devices: NanoVNA, NanoVNA-H, NanoVNA-H4, NanoVNA-F, AVNA via Teensy
- Splitting a frequency range into multiple segments to increase resolution (tried up to >10k points)
- Reading data from a NanoVNA -- Compatible devices: NanoVNA, NanoVNA-H,
NanoVNA-H4, NanoVNA-F, AVNA via Teensy
- Splitting a frequency range into multiple segments to increase resolution
(tried up to >10k points)
- Averaging data for better results particularly at higher frequencies
- Displaying data on multiple chart types, such as Smith, LogMag, Phase and VSWR-charts, for both S11 and S21
- Displaying markers, and the impedance, VSWR, Q, equivalent capacitance/inductance etc. at these locations
- Displaying customizable frequency bands as reference, for example amateur radio bands
- Displaying data on multiple chart types, such as Smith, LogMag, Phase and
VSWR-charts, for both S11 and S21
- Displaying markers, and the impedance, VSWR, Q, equivalent
capacitance/inductance etc. at these locations
- Displaying customizable frequency bands as reference, for example amateur
radio bands
- Exporting and importing 1-port and 2-port Touchstone files
- TDR function (measurement of cable length) - including impedance display
- Filter analysis functions for low-pass, high-pass, band-pass and band-stop filters
- Filter analysis functions for low-pass, high-pass, band-pass and band-stop
filters
- Display of both an active and a reference trace
- Live updates of data from the NanoVNA, including for multi-segment sweeps
- In-application calibration, including compensation for non-ideal calibration standards
- In-application calibration, including compensation for non-ideal calibration
standards
- Customizable display options, including "dark mode"
- Exporting images of plotted values
@ -41,17 +50,20 @@ Current features:
### Windows
The software was written in Python on Windows, using Pycharm, and the modules PyQT5, numpy, scipy and pyserial.
The software was written in Python on Windows, using Pycharm, and the modules
PyQT5, numpy, scipy and pyserial.
#### Binary releases
You can find the latest binary (.exe) release for Windows at https://github.com/mihtjel/nanovna-saver/releases/latest
You can find the latest binary (.exe) release for Windows at
https://github.com/mihtjel/nanovna-saver/releases/latest
The downloadable executable runs directly, and requires no installation. For Windows 7, it does require Service Pack 1
and [Microsoft VC++ Redistributable](https://support.microsoft.com/en-us/help/2977003/the-latest-supported-visual-c-downloads).
The downloadable executable runs directly, and requires no installation. For
Windows 7, it does require Service Pack 1 and [Microsoft VC++
Redistributable](https://support.microsoft.com/en-us/help/2977003/the-latest-supported-visual-c-downloads).
For most users, this is already installed.
Windows versions older than Windows 7 are not known to work.
It may be possible to run on those directly from the python code:
Windows versions older than Windows 7 are not known to work. It may be
possible to run on those directly from the python code:
#### Installation and Use with pip
@ -80,11 +92,14 @@ It may be possible to run on those directly from the python code:
git clone https://github.com/mihtjel/nanovna-saver
cd nanovna-saver
4. Run the pip installation
4. Update pip and run the pip installation
python3.7 -m pip install -U pip
python3.7 -m pip install .
(You may need to install the additional packages python3-distutils, python3-setuptools and python3-wheel for this command to work on some distributions.)
(You may need to install the additional packages python3-distutils,
python3-setuptools and python3-wheel for this command to work on some
distributions.)
5. Once completed run with the following command
@ -114,58 +129,76 @@ It may be possible to run on those directly from the python code:
## Using the software
Connect your NanoVNA to a serial port, and enter this serial port in the serial port box. If the NanoVNA is
connected before the application starts, it should be automatically detected. Otherwise, click "Rescan". Click
"Connect to device" to connect.
Connect your NanoVNA to a serial port, and enter this serial port in the serial
port box. If the NanoVNA is connected before the application starts, it should
be automatically detected. Otherwise, click "Rescan". Click "Connect to device"
to connect.
The app can collect multiple segments to get more accurate measurements. Enter the number of segments to be done in the
"Segments" box. Each segment is 101 data points, and takes about 1.5 seconds to complete.
The app can collect multiple segments to get more accurate measurements. Enter
the number of segments to be done in the "Segments" box. Each segment is 101
data points, and takes about 1.5 seconds to complete.
Frequencies are entered in Hz, or suffixed with k or M. Scientific notation (6.5e6 for 6.5MHz) also works.
Frequencies are entered in Hz, or suffixed with k or M. Scientific notation
(6.5e6 for 6.5MHz) also works.
Markers can be manually entered, or controlled using the mouse. For mouse control, select the active marker using the
radio buttons, or hold "shift" while clicking to drag the nearest marker. The marker readout boxes show the actual
frequency where values are measured. Marker readouts can be hidden using the "hide data" button when not needed.
Markers can be manually entered, or controlled using the mouse. For mouse
control, select the active marker using the radio buttons, or hold "shift"
while clicking to drag the nearest marker. The marker readout boxes show the
actual frequency where values are measured. Marker readouts can be hidden
using the "hide data" button when not needed.
Display settings are available under "Display setup". These allow changing the chart colours, the application font size
and which graphs are displayed. The settings are saved between program starts.
Display settings are available under "Display setup". These allow changing the
chart colours, the application font size and which graphs are displayed. The
settings are saved between program starts.
### Calibration
_Before using NanoVNA-Saver, please ensure that the device itself is in a reasonable calibration state._ A calibration
of both ports across the entire frequency span, saved to save slot 0, is sufficient. If the NanoVNA is completely
uncalibrated, its readings may be outside the range accepted by the application.
_Before using NanoVNA-Saver, please ensure that the device itself is in a
reasonable calibration state._ A calibration of both ports across the entire
frequency span, saved to save slot 0, is sufficient. If the NanoVNA is
completely uncalibrated, its readings may be outside the range accepted by the
application.
In-application calibration is available, either assuming ideal standards, or with relevant standard correction. To
manually calibrate, sweep each standard in turn, and press the relevant button in the calibration window. For assisted
calibration, press the "Calibration assistant" button. If desired, enter a note in the provided field describing the
conditions under which the calibration was performed.
In-application calibration is available, either assuming ideal standards, or
with relevant standard correction. To manually calibrate, sweep each standard
in turn, and press the relevant button in the calibration window. For assisted
calibration, press the "Calibration assistant" button. If desired, enter a
note in the provided field describing the conditions under which the
calibration was performed.
Calibration results may be saved and loaded using the provided buttons at the bottom of the window. Notes are saved
and loaded along with the calibration data.
Calibration results may be saved and loaded using the provided buttons at the
bottom of the window. Notes are saved and loaded along with the calibration
data.
![Screenshot of Calibration Window](https://i.imgur.com/p94cxOX.png)
Users of known characterized calibration standard sets can enter the data for these, and save the sets.
Users of known characterized calibration standard sets can enter the data for
these, and save the sets.
After pressing _Apply_, the calibration is immediately applied to the latest sweep data.
After pressing _Apply_, the calibration is immediately applied to the latest
sweep data.
_Currently, load capacitance is unsupported_
### TDR
To get accurate TDR measurements, calibrate the device, and attach the cable to be measured at the calibration plane -
ie. at the same position where the calibration load would be attached. Open the "Time Domain Reflectometry" window, and
select the correct cable type, or manually enter a propagation factor.
To get accurate TDR measurements, calibrate the device, and attach the cable to
be measured at the calibration plane - ie. at the same position where the
calibration load would be attached. Open the "Time Domain Reflectometry"
window, and select the correct cable type, or manually enter a propagation
factor.
### Frequency bands
Open the "Display setup" window to configure the display of frequency bands. By clicking "show bands", predefined
frequency bands will be shown on the frequency-based charts. Click manage bands to change which bands are shown, and
the frequency limits of each. Bands default and reset to European amateur radio band frequencies.
Open the "Display setup" window to configure the display of frequency bands. By
clicking "show bands", predefined frequency bands will be shown on the
frequency-based charts. Click manage bands to change which bands are shown,
and the frequency limits of each. Bands default and reset to European amateur
radio band frequencies.
## License
This software is licensed under version 3 of the GNU General Public License. It comes with NO WARRANTY.
This software is licensed under version 3 of the GNU General Public License. It
comes with NO WARRANTY.
You can use it, commercially as well. You may make changes to the code, but I (and the license) ask that you give these
changes back to the community.
You can use it, commercially as well. You may make changes to the code, but I
(and the license) ask that you give these changes back to the community.
## Links
* Ohan Smit wrote an introduction to using the application: [https://zs1sci.com/blog/nanovnasaver/]
@ -178,15 +211,18 @@ Original application by Rune B. Broberg (5Q5R)
Contributions and changes by Holger Müller, David Hunt and others.
TDR inspiration shamelessly stolen from the work of Salil (VU2CWA) at https://nuclearrambo.com/wordpress/accurately-measuring-cable-length-with-nanovna/
TDR inspiration shamelessly stolen from the work of Salil (VU2CWA) at
https://nuclearrambo.com/wordpress/accurately-measuring-cable-length-with-nanovna/
TDR cable types by Larry Goga.
Bugfixes and Python installation work by Ohan Smit.
Thanks to everyone who have tested, commented and inspired. Particular thanks go to the alpha testing crew who suffer
the early instability of new versions.
Thanks to everyone who have tested, commented and inspired. Particular thanks
go to the alpha testing crew who suffer the early instability of new versions.
This software is available free of charge. If you read all this way, and you *still* want to support it, you may donate to the developer using the button below:
This software is available free of charge. If you read all this way, and you
*still* want to support it, you may donate to the developer using the button
below:
[![Paypal](https://www.paypalobjects.com/en_US/i/btn/btn_donate_LG.gif)](https://www.paypal.com/cgi-bin/webscr?cmd=_donations&business=T8KTGVDQF5K6E&item_name=NanoVNASaver+Development&currency_code=EUR&source=url)