kopia lustrzana https://github.com/peterhinch/micropython-samples
Phase doc updated to match latest firmware.
rodzic
079180be6d
commit
7bcf1e6703
|
@ -1,14 +1,10 @@
|
|||
# Measurement of relative timing and phase of fast analog signals
|
||||
|
||||
With the current MicroPython firmware for the Pyboard it is difficult to
|
||||
measure the relative timing of multiple analog signals. There is a
|
||||
[PR](https://github.com/micropython/micropython/pull/3673) awaiting review
|
||||
which provides a solution. This may be downloaded and the firmware built.
|
||||
|
||||
Alternatively copy `adc.py` from this repo to `ports/stm32/adc.c` and rebuild.
|
||||
|
||||
This provides the static method `ADC.read_timed_multi` which is necessary to
|
||||
apply the techniques described below.
|
||||
As of 11th April 2018 the Pyboard firmware has been enhanced to enable multiple
|
||||
ADC channels to be read in a similar way to the existing `read_timed` method.
|
||||
At each timer tick a reading is taken from each ADC in very quick succession.
|
||||
This enables the relative timing or phase of relatively fast signals to be
|
||||
measured.
|
||||
|
||||
The ability to perform such measurements substantially increases the potential
|
||||
application areas of the Pyboard, supporting precision measurements of signals
|
||||
|
@ -52,6 +48,8 @@ running at the desired sampling frequency.
|
|||
Example reading 3 ADC's:
|
||||
|
||||
```python
|
||||
import pyb
|
||||
import array
|
||||
adc0 = pyb.ADC(pyb.Pin.board.X1) # Create ADC's
|
||||
adc1 = pyb.ADC(pyb.Pin.board.X2)
|
||||
adc2 = pyb.ADC(pyb.Pin.board.X3)
|
||||
|
@ -75,15 +73,14 @@ precision in the sample interval. In extreme cases samples may be missed.
|
|||
|
||||
The maximum rate depends on factors including the data width and the number of
|
||||
ADC's being read. In testing two ADC's were sampled at 12 bit precision and at
|
||||
a timer rate of 140KHz without overrun. Samples were missed at 180KHz. At high
|
||||
sample rates disabling interrupts for the duration can reduce the risk of
|
||||
sporadic data loss.
|
||||
a timer rate of 210KHz without overrun. At high sample rates disabling
|
||||
interrupts for the duration can reduce the risk of sporadic data loss.
|
||||
|
||||
# 2 Applications
|
||||
|
||||
## 2.1 Measurements of relative timing
|
||||
|
||||
In practice `ADC.read_timed_multi` reads each ADC in turn This implies a delay
|
||||
In practice `ADC.read_timed_multi` reads each ADC in turn. This implies a delay
|
||||
between each reading. This was measured at 3.236μs on a Pyboard V1.1 and can be
|
||||
used to compensate any measurements taken.
|
||||
|
||||
|
|