2020-11-28 02:40:47 +00:00
|
|
|
syntax = "proto3";
|
|
|
|
|
2020-12-07 11:49:43 +00:00
|
|
|
option java_package = "com.geeksville.mesh";
|
|
|
|
option java_outer_classname = "Portnums";
|
|
|
|
option optimize_for = LITE_RUNTIME;
|
|
|
|
|
2021-01-29 02:11:10 +00:00
|
|
|
/*
|
|
|
|
* For any new 'apps' that run on the device or via sister apps on phones/PCs they should pick and use a
|
|
|
|
* unique 'portnum' for their application.
|
|
|
|
*
|
|
|
|
* If you are making a new app using meshtastic, please send in a pull request to add your 'portnum' to this
|
|
|
|
* master table. PortNums should be assigned in the following range:
|
|
|
|
*
|
|
|
|
* 0-63 Core Meshtastic use, do not use for third party apps
|
|
|
|
* 64-127 Registered 3rd party apps, send in a pull request that adds a new entry to portnums.proto to register your application
|
|
|
|
* 256-511 Use one of these portnums for your private applications that you don't want to register publically
|
|
|
|
*
|
|
|
|
* All other values are reserved.
|
|
|
|
*
|
|
|
|
* Note: This was formerly a Type enum named 'typ' with the same id #
|
|
|
|
*
|
|
|
|
* We have change to this 'portnum' based scheme for specifying app handlers for particular payloads.
|
|
|
|
* This change is backwards compatible by treating the legacy OPAQUE/CLEAR_TEXT values identically.
|
|
|
|
*/
|
2020-11-28 02:40:47 +00:00
|
|
|
enum PortNum {
|
2021-01-29 02:11:10 +00:00
|
|
|
|
|
|
|
/*
|
|
|
|
* Deprecated: do not use in new code (formerly called OPAQUE)
|
|
|
|
* A message sent from a device outside of the mesh, in a form the mesh does not understand
|
|
|
|
* NOTE: This must be 0, because it is documented in IMeshService.aidl to be so
|
|
|
|
*/
|
2020-12-04 10:32:18 +00:00
|
|
|
UNKNOWN_APP = 0;
|
2020-11-28 02:40:47 +00:00
|
|
|
|
2021-01-29 02:11:10 +00:00
|
|
|
/*
|
|
|
|
* A simple UTF-8 text message, which even the little micros in the mesh
|
|
|
|
* can understand and show on their screen eventually in some circumstances
|
|
|
|
* even signal might send messages in this form (see below)
|
|
|
|
* Formerly called CLEAR_TEXT
|
|
|
|
*/
|
2020-11-28 02:40:47 +00:00
|
|
|
TEXT_MESSAGE_APP = 1;
|
|
|
|
|
2021-01-29 02:11:10 +00:00
|
|
|
/*
|
|
|
|
* A message receive acknowledgement, sent in cleartext - allows radio to
|
|
|
|
* show user that a message has been read by the recipient, optional
|
|
|
|
*
|
|
|
|
* Note: this concept has been removed for now. Once READACK is implemented, use the
|
|
|
|
* new packet type/port number stuff?
|
|
|
|
*
|
|
|
|
* @exclude
|
|
|
|
*
|
|
|
|
* CLEAR_READACK = 2;
|
|
|
|
*
|
|
|
|
* Reserved for built-in GPIO/example app.
|
|
|
|
* See remote_hardware.proto/HardwareMessage for details on the message sent/received to this port number
|
|
|
|
*/
|
2020-12-06 10:32:39 +00:00
|
|
|
REMOTE_HARDWARE_APP = 2;
|
2020-12-05 00:47:06 +00:00
|
|
|
|
2021-01-29 02:11:10 +00:00
|
|
|
/*
|
|
|
|
* The built-in position messaging app.
|
|
|
|
* See Position for details on the message sent to this port number.
|
|
|
|
*/
|
2020-11-28 10:10:11 +00:00
|
|
|
POSITION_APP = 3;
|
2020-12-04 10:32:18 +00:00
|
|
|
|
2021-01-29 02:11:10 +00:00
|
|
|
/*
|
|
|
|
* The built-in user info app.
|
|
|
|
* See User for details on the message sent to this port number.
|
|
|
|
*/
|
2020-12-05 01:23:57 +00:00
|
|
|
NODEINFO_APP = 4;
|
2020-11-28 04:09:11 +00:00
|
|
|
|
2021-01-29 02:11:10 +00:00
|
|
|
/*
|
|
|
|
* Provides a 'ping' service that replies to any packet it receives. Also this serves as a small example plugin.
|
|
|
|
*/
|
2020-12-11 00:32:16 +00:00
|
|
|
REPLY_APP = 32;
|
|
|
|
|
2021-01-29 02:11:10 +00:00
|
|
|
/*
|
|
|
|
* Used for the python IP tunnel feature
|
|
|
|
*/
|
2020-12-23 09:45:28 +00:00
|
|
|
IP_TUNNEL_APP = 33;
|
|
|
|
|
2021-01-29 02:11:10 +00:00
|
|
|
/*
|
|
|
|
* Provides a hardware serial interface to send and receive from the Meshtastic network.
|
|
|
|
* Connect to the RX/TX pins of a device with 38400 8N1. Packets received from the Meshtastic
|
|
|
|
* network is forwarded to the RX pin while sending a packet to TX will go out to the Mesh
|
|
|
|
* network. Maximum packet size of 240 bytes.
|
|
|
|
*
|
|
|
|
* Maintained by Jm Casler (MC Hamster) : jm@casler.org
|
|
|
|
*/
|
2021-01-13 05:53:16 +00:00
|
|
|
SERIAL_APP = 64;
|
|
|
|
|
2021-01-29 02:11:10 +00:00
|
|
|
/*
|
2021-02-06 01:56:17 +00:00
|
|
|
* STORE_FORWARD_APP (Work in Progress)
|
2021-01-29 02:11:10 +00:00
|
|
|
*
|
|
|
|
* Maintained by Jm Casler (MC Hamster) : jm@casler.org
|
|
|
|
*/
|
2021-02-06 01:56:17 +00:00
|
|
|
STORE_FORWARD_APP = 65;
|
2021-01-29 02:11:10 +00:00
|
|
|
|
|
|
|
/*
|
|
|
|
* Private applications should use portnums >= 256.
|
|
|
|
* To simplify initial development and testing you can use "PRIVATE_APP"
|
|
|
|
* in your code without needing to rebuild protobuf files (via bin/regin_protos.sh)
|
|
|
|
*/
|
2020-11-28 04:09:11 +00:00
|
|
|
PRIVATE_APP = 256;
|
2021-01-29 02:11:10 +00:00
|
|
|
|
|
|
|
/*
|
|
|
|
* ATAK Forwarder Plugin https://github.com/paulmandal/atak-forwarder
|
|
|
|
*/
|
|
|
|
ATAK_FORWARDER = 257;
|
2021-01-13 05:53:16 +00:00
|
|
|
}
|