meshtastic-firmware/variants/station-g1
Gabriele Russo 7c9d1b0abf
Battery level with proportional filter and lookup table (#3216)
* Add battery level with lookup table

now uses a lookup table to better calculate battery level of different cells

* LifePo4 and PB battery table - added voltage filter

removed delay from adc reading, added a software filter to smooth out voltage readings. In those applications battery would last hours to days, no sudden change should be expected so a less frequent voltage reading or a more aggressive filtering could be done.
Note: to speed up convergence i initiliazied the last value to the minimum voltage, there are other and better ways to init the filter.

Added LiFePO4 and PB  open circuit volta battery tables,

* Fixed ADC_CTRL , Checks for valid ADC readings

line 230/386 For heltec v3 and heltec tracker a different approach was used with the ADC_CTRL pin, now is more uniform using the same code for the 3 boards.

line 236 Check if the raw reading we are getting is Valid or not, count only the valid readings. This could lead to a division by 0 (improbable) so that's why at line 258 there is a check for that.

* updated OCV values

updated value to not OCV but to very low current, almost the same anyway

* Added Alkaline/Nimh voltage curve

Added Alkaline/Nimh voltage curve for AA/AAA and similar cells

* updates variants for new capacity measurement

* trunk reformatting

* trunk fmt

* Add LTO chemistry

---------

Co-authored-by: Ben Meadors <benmmeadors@gmail.com>
Co-authored-by: code8buster <20384924+code8buster@users.noreply.github.com>
2024-02-16 06:09:57 -06:00
..
platformio.ini 'station-g1' 2022-08-03 04:23:32 +08:00
variant.h Battery level with proportional filter and lookup table (#3216) 2024-02-16 06:09:57 -06:00