kopia lustrzana https://github.com/jbruce12000/kiln-controller
Initial config changes
rodzic
7c7a1b648e
commit
e38808b5e0
21
config.py
21
config.py
|
@ -2,7 +2,7 @@ import logging
|
|||
import os
|
||||
|
||||
# uncomment this if using MAX-31856
|
||||
#from lib.max31856 import MAX31856
|
||||
from lib.max31856 import MAX31856
|
||||
|
||||
########################################################################
|
||||
#
|
||||
|
@ -22,9 +22,9 @@ listening_port = 8081
|
|||
# to produce the actual cost during a run. My kiln has three
|
||||
# elements that when my switches are set to high, consume 9460 watts.
|
||||
|
||||
kwh_rate = 0.1319 # cost per kilowatt hour per currency_type to calculate cost to run job
|
||||
kw_elements = 9.460 # if the kiln elements are on, the wattage in kilowatts
|
||||
currency_type = "$" # Currency Symbol to show when calculating cost to run job
|
||||
kwh_rate = 0.33631 # cost per kilowatt hour per currency_type to calculate cost to run job
|
||||
kw_elements = 7.0 # if the kiln elements are on, the wattage in kilowatts
|
||||
currency_type = "£" # Currency Symbol to show when calculating cost to run job
|
||||
|
||||
########################################################################
|
||||
#
|
||||
|
@ -41,11 +41,11 @@ gpio_heat = 23 # Switches zero-cross solid-state-relay
|
|||
### Thermocouple Adapter selection:
|
||||
# max31855 - bitbang SPI interface
|
||||
# max31856 - bitbang SPI interface. must specify thermocouple_type.
|
||||
max31855 = 1
|
||||
max31856 = 0
|
||||
max31855 = 0
|
||||
max31856 = 1
|
||||
# see lib/max31856.py for other thermocouple_type, only applies to max31856
|
||||
# uncomment this if using MAX-31856
|
||||
#thermocouple_type = MAX31856.MAX31856_S_TYPE
|
||||
thermocouple_type = MAX31856.MAX31856_S_TYPE
|
||||
|
||||
### Thermocouple Connection (using bitbang interfaces)
|
||||
gpio_sensor_cs = 27
|
||||
|
@ -105,7 +105,7 @@ sim_R_ho_air = 0.05 # K/W " with internal air circulation
|
|||
# If you change the temp_scale, all settings in this file are assumed to
|
||||
# be in that scale.
|
||||
|
||||
temp_scale = "f" # c = Celsius | f = Fahrenheit - Unit to display
|
||||
temp_scale = "c" # c = Celsius | f = Fahrenheit - Unit to display
|
||||
time_scale_slope = "h" # s = Seconds | m = Minutes | h = Hours - Slope displayed in temp_scale per time_scale_slope
|
||||
time_scale_profile = "m" # s = Seconds | m = Minutes | h = Hours - Enter and view target time in time_scale_profile
|
||||
|
||||
|
@ -114,7 +114,8 @@ time_scale_profile = "m" # s = Seconds | m = Minutes | h = Hours - Enter and vi
|
|||
# naturally cool off. If your SSR has failed/shorted/closed circuit, this
|
||||
# means your kiln receives full power until your house burns down.
|
||||
# this should not replace you watching your kiln or use of a kiln-sitter
|
||||
emergency_shutoff_temp = 2264 #cone 7
|
||||
#emergency_shutoff_temp = 2264 #cone 7
|
||||
emergency_shutoff_temp = 1300 # TODO: check if the change of temp scale also changes interpretation of these constants
|
||||
|
||||
# If the current temperature is outside the pid control window,
|
||||
# delay the schedule until it does back inside. This allows for heating
|
||||
|
@ -143,7 +144,7 @@ thermocouple_offset=0
|
|||
temperature_average_samples = 40
|
||||
|
||||
# Thermocouple AC frequency filtering - set to True if in a 50Hz locale, else leave at False for 60Hz locale
|
||||
ac_freq_50hz = False
|
||||
ac_freq_50hz = True
|
||||
|
||||
########################################################################
|
||||
# Emergencies - or maybe not
|
||||
|
|