esp-idf/examples/common_components/protocol_examples_common/Kconfig.projbuild

301 wiersze
11 KiB
Plaintext

menu "Example Connection Configuration"
config EXAMPLE_CONNECT_WIFI
bool "connect using WiFi interface"
default y
help
Protocol examples can use Wi-Fi and/or Ethernet to connect to the network.
Choose this option to connect with WiFi
if EXAMPLE_CONNECT_WIFI
config EXAMPLE_WIFI_SSID
string "WiFi SSID"
default "myssid"
help
SSID (network name) for the example to connect to.
config EXAMPLE_WIFI_PASSWORD
string "WiFi Password"
default "mypassword"
help
WiFi password (WPA or WPA2) for the example to use.
Can be left blank if the network has no security set.
choice EXAMPLE_WIFI_SCAN_METHOD
prompt "WiFi Scan Method"
default EXAMPLE_WIFI_SCAN_METHOD_FAST
help
WiFi scan method:
If "Fast" is selected, scan will end after find SSID match AP.
If "All Channel" is selected, scan will end after scan all the channel.
config EXAMPLE_WIFI_SCAN_METHOD_FAST
bool "Fast"
config EXAMPLE_WIFI_SCAN_METHOD_ALL_CHANNEL
bool "All Channel"
endchoice
menu "WiFi Scan threshold"
config EXAMPLE_WIFI_SCAN_RSSI_THRESHOLD
int "WiFi minimum rssi"
range -127 0
default -127
help
The minimum rssi to accept in the scan mode.
choice EXAMPLE_WIFI_SCAN_AUTH_MODE_THRESHOLD
prompt "WiFi Scan auth mode threshold"
default EXAMPLE_WIFI_AUTH_OPEN
help
The weakest authmode to accept in the scan mode.
config EXAMPLE_WIFI_AUTH_OPEN
bool "OPEN"
config EXAMPLE_WIFI_AUTH_WEP
bool "WEP"
config EXAMPLE_WIFI_AUTH_WPA_PSK
bool "WPA PSK"
config EXAMPLE_WIFI_AUTH_WPA2_PSK
bool "WPA2 PSK"
config EXAMPLE_WIFI_AUTH_WPA_WPA2_PSK
bool "WPA WPA2 PSK"
config EXAMPLE_WIFI_AUTH_WPA2_ENTERPRISE
bool "WPA2 ENTERPRISE"
config EXAMPLE_WIFI_AUTH_WPA3_PSK
bool "WPA3 PSK"
config EXAMPLE_WIFI_AUTH_WPA2_WPA3_PSK
bool "WPA2 WPA3 PSK"
config EXAMPLE_WIFI_AUTH_WAPI_PSK
bool "WAPI PSK"
endchoice
endmenu
choice EXAMPLE_WIFI_CONNECT_AP_SORT_METHOD
prompt "WiFi Connect AP Sort Method"
default EXAMPLE_WIFI_CONNECT_AP_BY_SIGNAL
help
WiFi connect AP sort method:
If "Signal" is selected, Sort matched APs in scan list by RSSI.
If "Security" is selected, Sort matched APs in scan list by security mode.
config EXAMPLE_WIFI_CONNECT_AP_BY_SIGNAL
bool "Signal"
config EXAMPLE_WIFI_CONNECT_AP_BY_SECURITY
bool "Security"
endchoice
endif
config EXAMPLE_CONNECT_ETHERNET
bool "connect using Ethernet interface"
default n
help
Protocol examples can use Wi-Fi and/or Ethernet to connect to the network.
Choose this option to connect with Ethernet
if EXAMPLE_CONNECT_ETHERNET
config EXAMPLE_USE_SPI_ETHERNET
bool
choice EXAMPLE_ETHERNET_TYPE
prompt "Ethernet Type"
default EXAMPLE_USE_INTERNAL_ETHERNET if IDF_TARGET_ESP32
default EXAMPLE_USE_W5500
help
Select which kind of Ethernet will be used in the example.
config EXAMPLE_USE_INTERNAL_ETHERNET
depends on IDF_TARGET_ESP32
select ETH_USE_ESP32_EMAC
bool "Internal EMAC"
help
Select internal Ethernet MAC controller.
config EXAMPLE_USE_DM9051
bool "DM9051 Module"
select EXAMPLE_USE_SPI_ETHERNET
select ETH_USE_SPI_ETHERNET
select ETH_SPI_ETHERNET_DM9051
help
Select external SPI-Ethernet module.
config EXAMPLE_USE_W5500
bool "W5500 Module"
select EXAMPLE_USE_SPI_ETHERNET
select ETH_USE_SPI_ETHERNET
select ETH_SPI_ETHERNET_W5500
help
Select external SPI-Ethernet module (W5500).
config EXAMPLE_USE_OPENETH
bool "OpenCores Ethernet MAC (EXPERIMENTAL)"
select ETH_USE_OPENETH
help
When this option is enabled, the example is built with support for
OpenCores Ethernet MAC, which allows testing the example in QEMU.
Note that this option is used for internal testing purposes, and
not officially supported. Examples built with this option enabled
will not run on a real ESP32 chip.
endchoice # EXAMPLE_ETHERNET_TYPE
if EXAMPLE_USE_INTERNAL_ETHERNET
choice EXAMPLE_ETH_PHY_MODEL
prompt "Ethernet PHY Device"
default EXAMPLE_ETH_PHY_IP101
help
Select the Ethernet PHY device to use in the example.
config EXAMPLE_ETH_PHY_IP101
bool "IP101"
help
IP101 is a single port 10/100 MII/RMII/TP/Fiber Fast Ethernet Transceiver.
Goto http://www.icplus.com.tw/pp-IP101G.html for more information about it.
config EXAMPLE_ETH_PHY_RTL8201
bool "RTL8201/SR8201"
help
RTL8201F/SR8201F is a single port 10/100Mb Ethernet Transceiver with auto MDIX.
Goto http://www.corechip-sz.com/productsview.asp?id=22 for more information about it.
config EXAMPLE_ETH_PHY_LAN8720
bool "LAN8720"
help
LAN8720A is a small footprint RMII 10/100 Ethernet Transceiver with HP Auto-MDIX Support.
Goto https://www.microchip.com/LAN8720A for more information about it.
config EXAMPLE_ETH_PHY_DP83848
bool "DP83848"
help
DP83848 is a single port 10/100Mb/s Ethernet Physical Layer Transceiver.
Goto http://www.ti.com/product/DP83848J for more information about it.
endchoice
config EXAMPLE_ETH_MDC_GPIO
int "SMI MDC GPIO number"
default 23
help
Set the GPIO number used by SMI MDC.
config EXAMPLE_ETH_MDIO_GPIO
int "SMI MDIO GPIO number"
default 18
help
Set the GPIO number used by SMI MDIO.
endif
if EXAMPLE_USE_SPI_ETHERNET
config EXAMPLE_ETH_SPI_HOST
int "SPI Host Number"
range 0 2
default 1
help
Set the SPI host used to communicate with the SPI Ethernet Controller.
config EXAMPLE_ETH_SPI_SCLK_GPIO
int "SPI SCLK GPIO number"
range 0 33
default 20
help
Set the GPIO number used by SPI SCLK.
config EXAMPLE_ETH_SPI_MOSI_GPIO
int "SPI MOSI GPIO number"
range 0 33
default 19
help
Set the GPIO number used by SPI MOSI.
config EXAMPLE_ETH_SPI_MISO_GPIO
int "SPI MISO GPIO number"
range 0 33
default 18
help
Set the GPIO number used by SPI MISO.
config EXAMPLE_ETH_SPI_CS_GPIO
int "SPI CS GPIO number"
range 0 33
default 21
help
Set the GPIO number used by SPI CS.
config EXAMPLE_ETH_SPI_CLOCK_MHZ
int "SPI clock speed (MHz)"
range 20 80
default 36
help
Set the clock speed (MHz) of SPI interface.
config EXAMPLE_ETH_SPI_INT_GPIO
int "Interrupt GPIO number"
default 4
help
Set the GPIO number used by the SPI Ethernet module interrupt line.
endif # EXAMPLE_USE_SPI_ETHERNET
config EXAMPLE_ETH_PHY_RST_GPIO
int "PHY Reset GPIO number"
default 5
help
Set the GPIO number used to reset PHY chip.
Set to -1 to disable PHY chip hardware reset.
config EXAMPLE_ETH_PHY_ADDR
int "PHY Address"
range 0 31 if EXAMPLE_USE_INTERNAL_ETHERNET
default 1
help
Set PHY address according your board schematic.
endif # EXAMPLE_CONNECT_ETHERNET
config EXAMPLE_CONNECT_IPV6
bool "Obtain IPv6 address"
default y
depends on EXAMPLE_CONNECT_WIFI || EXAMPLE_CONNECT_ETHERNET
select LWIP_IPV6
help
By default, examples will wait until IPv4 and IPv6 local link addresses are obtained.
Disable this option if the network does not support IPv6.
Choose the preferred IPv6 address type if the connection code should wait until other than
the local link address gets assigned.
Consider enabling IPv6 stateless address autoconfiguration (SLAAC) in the LWIP component.
if EXAMPLE_CONNECT_IPV6
choice EXAMPLE_CONNECT_PREFERRED_IPV6
prompt "Preferred IPv6 Type"
default EXAMPLE_CONNECT_IPV6_PREF_LOCAL_LINK
help
Select which kind of IPv6 address the connect logic waits for.
config EXAMPLE_CONNECT_IPV6_PREF_LOCAL_LINK
bool "Local Link Address"
help
Blocks until Local link address assigned.
config EXAMPLE_CONNECT_IPV6_PREF_GLOBAL
bool "Global Address"
help
Blocks until Global address assigned.
config EXAMPLE_CONNECT_IPV6_PREF_SITE_LOCAL
bool "Site Local Address"
help
Blocks until Site link address assigned.
config EXAMPLE_CONNECT_IPV6_PREF_UNIQUE_LOCAL
bool "Unique Local Link Address"
help
Blocks until Unique local address assigned.
endchoice
endif
endmenu