esp-idf/examples/storage/nvs_rw_value
Ivan Grokhotkov e596c84d49 build system: re-add -Wno-format as private flag for some example components 2022-08-03 16:42:47 +04:00
..
main build system: re-add -Wno-format as private flag for some example components 2022-08-03 16:42:47 +04:00
CMakeLists.txt tools: Increase the minimal supported CMake version to 3.16 2022-06-01 06:35:02 +00:00
README.md docs: changes docs supported targets tables 2022-07-14 08:26:32 +08:00
pytest_nvs_rw_value.py storage examples migrated to pytest 2022-07-22 10:23:53 +02:00
sdkconfig.ci

README.md

Supported Targets ESP32 ESP32-C3 ESP32-S2 ESP32-S3

Non-Volatile Storage (NVS) Read and Write Example

(See the README.md file in the upper level 'examples' directory for more information about examples.)

This example demonstrates how to read and write a single integer value using NVS.

In this example, value which is saved holds the number of ESP32 module restarts. Since it is written to NVS, the value is preserved between restarts.

Example also shows how to check if read / write operation was successful, or certain value is not initialized in NVS. Diagnostic is provided in plain text to help track program flow and capture any issues on the way.

Detailed functional description of NVS and API is provided in documentation.

Check another example storage/nvs_rw_blob, which shows how to read and write variable length binary data (blob).

How to use example

Hardware required

This example does not require any special hardware, and can be run on any common development board.

Build and flash

Build the project and flash it to the board, then run monitor tool to view serial output:

idf.py -p PORT flash monitor

(To exit the serial monitor, type Ctrl-].)

See the Getting Started Guide for full steps to configure and use ESP-IDF to build projects.

Example Output

First run:

Opening Non-Volatile Storage (NVS) handle... Done
Reading restart counter from NVS ... The value is not initialized yet!
Updating restart counter in NVS ... Done
Committing updates in NVS ... Done

Restarting in 10 seconds...
Restarting in 9 seconds...
Restarting in 8 seconds...
Restarting in 7 seconds...
Restarting in 6 seconds...
Restarting in 5 seconds...
Restarting in 4 seconds...
Restarting in 3 seconds...
Restarting in 2 seconds...
Restarting in 1 seconds...
Restarting in 0 seconds...
Restarting now.

Subsequent runs:

Opening Non-Volatile Storage (NVS) handle... Done
Reading restart counter from NVS ... Done
Restart counter = 1
Updating restart counter in NVS ... Done
Committing updates in NVS ... Done

Restarting in 10 seconds...
Restarting in 9 seconds...
Restarting in 8 seconds...
Restarting in 7 seconds...
Restarting in 6 seconds...
Restarting in 5 seconds...
Restarting in 4 seconds...
Restarting in 3 seconds...
Restarting in 2 seconds...
Restarting in 1 seconds...
Restarting in 0 seconds...
Restarting now.

Restart counter will increment on each run.

To reset the counter, erase the contents of flash memory using idf.py erase-flash, then upload the program again as described above.