esp-idf/examples/protocols/modbus/serial/mb_slave/main/Kconfig.projbuild

76 wiersze
2.6 KiB
Plaintext

menu "Modbus Example Configuration"
orsource "$IDF_PATH/examples/common_components/env_caps/$IDF_TARGET/Kconfig.env_caps"
config MB_UART_PORT_NUM
int "UART port number"
range 0 2 if IDF_TARGET_ESP32 || IDF_TARGET_ESP32S3
default 2 if IDF_TARGET_ESP32 || IDF_TARGET_ESP32S3
range 0 1 if IDF_TARGET_ESP32S2 || IDF_TARGET_ESP32C3
default 1 if IDF_TARGET_ESP32S2 || IDF_TARGET_ESP32C3
help
UART communication port number for Modbus example.
config MB_UART_BAUD_RATE
int "UART communication speed"
range 1200 115200
default 115200
help
UART communication speed for Modbus example.
config MB_UART_RXD
int "UART RXD pin number"
range ENV_GPIO_RANGE_MIN ENV_GPIO_IN_RANGE_MAX
default 22 if IDF_TARGET_ESP32
default 8 if IDF_TARGET_ESP32S2 || IDF_TARGET_ESP32S3 || IDF_TARGET_ESP32C3
help
GPIO number for UART RX pin. See UART documentation for more information
about available pin numbers for UART.
config MB_UART_TXD
int "UART TXD pin number"
range ENV_GPIO_RANGE_MIN ENV_GPIO_OUT_RANGE_MAX
default 23 if IDF_TARGET_ESP32
default 9 if IDF_TARGET_ESP32S2 || IDF_TARGET_ESP32S3 || IDF_TARGET_ESP32C3
help
GPIO number for UART TX pin. See UART documentation for more information
about available pin numbers for UART.
config MB_UART_RTS
int "UART RTS pin number"
range ENV_GPIO_RANGE_MIN ENV_GPIO_OUT_RANGE_MAX
default 18 if IDF_TARGET_ESP32
default 10 if IDF_TARGET_ESP32S2 || IDF_TARGET_ESP32S3 || IDF_TARGET_ESP32C3
help
GPIO number for UART RTS pin. This pin is connected to
~RE/DE pin of RS485 transceiver to switch direction.
See UART documentation for more information about available pin
numbers for UART.
choice MB_COMM_MODE
prompt "Modbus communication mode"
default MB_COMM_MODE_RTU if CONFIG_FMB_COMM_MODE_RTU_EN
help
Selection of Modbus communication mode option for Modbus.
config MB_COMM_MODE_RTU
bool "RTU mode"
depends on FMB_COMM_MODE_RTU_EN
config MB_COMM_MODE_ASCII
bool "ASCII mode"
depends on FMB_COMM_MODE_ASCII_EN
endchoice
config MB_SLAVE_ADDR
int "Modbus slave address"
range 1 127
default 1
help
This is the Modbus slave address in the network.
It is used to organize Modbus network with several slaves connected into the same segment.
endmenu